Felicity Solar Off-Grid Inverters 2-4 kW IVPS2512/IVPS2524/IVPS3524/IVPS5024
A 2 kW, 12 V inverter/charger that starts at 11.5 V, transfers in 15 ms and weighs 21 kg net in a low-frequency transformer chassis.
Models and prices
Technical Specifications
| Parameter | IVPS2512 | IVPS2524 | IVPS3524 | IVPS5024 |
|---|---|---|---|---|
| Performance & Electrical | ||||
| AC Output Voltage | 220 V | |||
| AC Wiring Mode | L+N+PE | |||
| Backup Rated Output Power | 2 kW | 2 kW | 2.8 kW | 4 kW |
| Battery Inputs | 1 | |||
| Battery Type | AGM, Flooded, Li-Ion, Self-Defined | |||
| Battery Voltage Range | 10.5-15.75 V | 21-31.5 V | 21-31.5 V | 21-31.5 V |
| Bulk Charging Voltage | 14.4 V | 28.8 V | 28.8 V | 28.8 V |
| Charge Algorithm | Three-Stage: Boost CC, Boost CV, Float | |||
| Float Charging Voltage | 13.6 V | 27.2 V | 27.2 V | 27.2 V |
| High DC Input Recovery Voltage | 15.5 V | 31 V | 31 V | 31 V |
| High Frequency Disconnect | 65 Hz | |||
| High Frequency Reconnect | 63 Hz | |||
| High Line Disconnect Voltage | 280 V | |||
| High Line Reconnect Voltage | 270 V | |||
| Input Voltage Range | 90-280 V | |||
| Input Voltage Range (Appliance Mode) | 90-280 V | |||
| Input Voltage Range (UPS Mode) | 170-280 V | |||
| Input Voltage Waveform | Sinusoidal (utility or generator) | |||
| Line Mode Efficiency | >95% | |||
| Line Mode Output Waveform | Same As Input Waveform | |||
| Low DC Shutdown (>50% Load) | 10.5 V | 21 V | 21 V | 21 V |
| Low Frequency Disconnect | 40 Hz | |||
| Low Frequency Reconnect | 42 Hz | |||
| Low Line Disconnect (Appliance Mode) | 90 V | |||
| Low Line Disconnect (UPS Mode) | 170 V | |||
| Low Line Reconnect (Appliance Mode) | 100 V | |||
| Low Line Reconnect (UPS Mode) | 180 V | |||
| Low-Battery Recovery (>50% Load) | 11.5 V | 23 V | 23 V | 23 V |
| Max AC Charge Current | 40 A | 40 A | 40 A | 50 A |
| Max AC Input Voltage | 280 V | |||
| Max AC Pass-Through Current | 30 A | 30 A | 30 A | 63 A |
| Max Charging Current | 40 A | 40 A | 40 A | 50 A |
| Max Charging Voltage | 16 V | 31.5 V | 31.5 V | 31.5 V |
| Max Efficiency | 90% | |||
| Max Output Overcurrent Protection | 30 A | |||
| Motor Start Capable | Yes | |||
| Nominal AC Input Voltage | 220 V | |||
| Nominal DC Input Voltage | 12 V | 24 V | 24 V | 24 V |
| Nominal Input Frequency | 50/60 Hz | |||
| Output Frequency | 50/60 Hz | |||
| Output Short-Circuit Protection | Yes | |||
| Output Voltage Regulation | 5% | |||
| Output Voltage Waveform | Pure Sine Wave | |||
| Overload Protection | Air Switch Protection | |||
| Overload Trip Time (>105% Load) | 10 s | |||
| Overload Trip Time (>150% Load) | 5 s | |||
| Pass-Through Without Battery | No | |||
| Phase | Single Phase | |||
| Protection | Over Charge Protection, Over Discharge Protection, Overload Protection, Output Short Circuit Protection, Over Temperature Protection | |||
| Rated Apparent Output Power | 2.5 kVA | 2.5 kVA | 3.5 kVA | 5 kVA |
| Rated Output Power | 2 kW | 2 kW | 2.8 kW | 4 kW |
| Short-Circuit Protection (Line Mode) | Air Switch Protection | |||
| Start-Up Voltage | 11.5 V | 23 V | 23 V | 23 V |
| Surge Rating | 2*rated (5s) | |||
| Transfer Time | 15 ms | |||
| Build & Interfaces | ||||
| BMS Communication | RS485 | |||
| Communication Interface | RS232 | |||
| Display | LCD, LED | |||
| Gross Weight | 24.4 kg | 24.1 kg | 29.4 kg | 32.5 kg |
| Net Weight | 21 kg | 20.7 kg | 26 kg | 29.1 kg |
| Package Dimensions | 552 x 408 x 290 mm | 552 x 408 x 290 mm | 552 x 408 x 295 mm | 607 x 540 x 290 mm |
| Parallel Capability | 6 | |||
| Topology | Low-Frequency (transformer-based) | |||
| Operating Environment | ||||
| Cooling | Intelligent Air Cooling | |||
| IP Rating | IP21 | |||
| Operating Temperature Range | 0-40 °C | |||
| Storage Temperature | -15 to 60 °C | |||
Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.
Availability & grid compliance in the UAE
| Market | UAE |
|---|---|
| Grid authority / regulator | DEWA, ADDC, SEWA |
| Quotation currency | AED |
| Support hours timezone | Asia/Dubai |
| Main cities | Dubai, Abu Dhabi, Sharjah, Ajman, Ras Al Khaimah |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in the UAE that rests with the local authorities (DEWA, ADDC, SEWA). Confirm the grid code, import requirements and any local certification with them, or with us, before you order.
Key Features & Technical Highlights
- 12 V bank across a 10.5-15.75 V window: One battery input, starting the inverter at 11.5 V, with AGM, flooded, Li-Ion and self-defined profiles.
- 40 A charging with a 14.4 V boost and a 13.6 V float: Charging voltage is capped at 16 V, drawn from a 90-280 V utility or generator supply.
- 2 kW rated output with twice rated power for 5 s: Backup output is also rated 2 kW, single phase at 220 V on an L+N+PE connection.
- 15 ms transfer and better than 95% line-mode efficiency: Conversion efficiency peaks at 90% and output voltage regulation stays within 5%.
- 21 kg net and 24.4 kg gross: The low-frequency, transformer-based build ships in a 552 x 408 x 290 mm carton.
- Up to 6 units in parallel with 30 A overcurrent protection: RS485 BMS link, RS232 port, LCD and LED display, IP21 rating and 0-40 °C operation.
- 2 kW rated and 2 kW backup output at 220 V: single phase on an L+N+PE connection, with output voltage regulation held to 5%
- 24 V battery bank, 21-31.5 V working window: a 23 V start-up voltage and a 31.5 V charging ceiling keep the IVPS2524 matched to 24 V
- 40 A maximum charge current, from battery or utility: 28.8 V boost then 27.2 V float, for AGM, Flooded, Li-Ion and Self-Defined banks
- 15 ms transfer with 2x rated surge for 5 seconds: utility input is accepted from 90 V to 280 V at 50/60 Hz
- 30 A output overcurrent protection: Air Switch overload protection alongside over-charge, over-discharge, output short-circuit and over-temperature protection
- 20.7 kg net and 24.1 kg gross in a 552 x 408 x 290 mm carton: a low-frequency transformer-based build, IP21, intelligent air cooling and 0-40 °C operation
Frequently Asked Questions
What battery bank does the Felicity Solar IVPS2512 need?
12 V nominal, through a single battery input. The IVPS2512 works between 10.5 V and 15.75 V, starts up at 11.5 V, and accepts AGM, flooded, Li-Ion and self-defined battery types.
How fast does the IVPS2512 charge a 12 V bank?
40 A maximum charge current. Charging boosts to 14.4 V, floats at 13.6 V and is capped at 16 V, taken from a 90-280 V supply at 50/60 Hz that may be utility or generator.
How much does the IVPS2512 weigh and what does it ship in?
21 kg net and 24.4 kg gross, in a 552 x 408 x 290 mm carton. That mass follows from a low-frequency, transformer-based topology, air cooled, rated IP21 and covered by a 2 Years warranty.
Can several IVPS2512 units run in parallel?
Up to 6 units. Each carries an RS485 BMS link and an RS232 port, an LCD and LED display, 30 A output overcurrent protection, air switch overload protection and a 0-40 °C operating range.
What battery voltage does the Felicity Solar IVPS2524 need?
24 V nominal, over a 21-31.5 V working range. The IVPS2524 starts at 23 V and charges to a 31.5 V ceiling, so the bank has to be a 24 V bank.
How fast can the IVPS2524 charge a battery?
40 A maximum charge current, and the same 40 A from the utility, delivered as a 28.8 V boost stage settling to a 27.2 V float across AGM, Flooded, Li-Ion and Self-Defined batteries.
How much does the IVPS2524 weigh and what box does it ship in?
20.7 kg net and 24.1 kg gross, in a 552 x 408 x 290 mm carton. The mass follows from the low-frequency transformer-based build.
Can several IVPS2524 units be run in parallel?
6 units in parallel. Each one is single phase at 220 V and 50/60 Hz on an L+N+PE connection, with 30 A output overcurrent protection.
What battery bank does the IVPS3524 need?
24 V nominal. The IVPS3524 works across a 21-31.5 V battery window, starts up at 23 V and takes a single battery input, with AGM, Flooded, Li-Ion and Self-Defined profiles all supported.
How fast can the IVPS3524 charge from the mains?
40 A is the maximum charge current. Charging boosts at 28.8 V, floats at 27.2 V and is capped at 31.5 V, so a 24 V bank refills without a separate charger.