E18Fault

Felicity inverter error E18

SPI Comm Fault

Faultthe inverter cuts its output and the red LED stays solid until the fault is cleared.

E-CHO-SI3KS2

InverterFault

Also applies to:E-CHO-SI5KS2E-CHO-SI8KS2

What it means

SPI Comm FaultSPI internal communication fault.

Cause: Communication has been lost between the inverter and a peripheral device — typically a battery BMS, smart meter, or external monitoring dongle.

How to fix it

  1. Verify the communication cable (CAN/RS485/Modbus) is correctly seated and the right pinout is used.
  2. Check baud rate and protocol settings in both devices match.
  3. Reseat the dongle/comms module.
  4. For BMS comms, confirm the battery is powered on and not in deep-discharge protection.

Source: E-CHO-SI3KS2-Operation-Manual.pdf, p.16 · E-CHO-SI5KS2-Operation-Manual.pdf · E-CHO-SI8KS2-Operation-Manual.pdf

Frequently asked questions

What does error E18 mean on a Felicity inverter?
E18 means: SPI Comm Fault. Communication has been lost between the inverter and a peripheral device — typically a battery BMS, smart meter, or external monitoring dongle.
Is error E18 a fault or a warning?
E18 is a fault code: the inverter cuts its output and the red LED stays solid until it is cleared.
How do I clear or fix error E18?
Verify the communication cable (CAN/RS485/Modbus) is correctly seated and the right pinout is used. Check baud rate and protocol settings in both devices match.

Related error codes

Prefer the full written guide? Read the complete Felicity inverter error-code guide

Compiled from official Felicity user manuals. Always consult your device manual and a qualified technician before performing repairs.