Felicity Solar IVPS5048P1G1-LV 4kW Single-Phase Inverter / Charger
A single-phase off-grid inverter charger rated 4 kW / 5 kVA, running a 110-127 V pure sine output from a 48 V battery bank. We supply it as an authorised Felicity Solar distributor.
- Rated Output Power: 4 kW
- Max Efficiency: 90 %
- Battery Voltage Range: 42-63 V
- Phase: Single Phase
In stock
Felicity Solar IVPS5048P1G1-LV 4kW Single-Phase Inverter / Charger features
About the Felicity Solar IVPS5048P1G1-LV 4kW Single-Phase Inverter / Charger
The Felicity Solar IVPS5048P1G1-LV is a single-phase off-grid inverter charger that delivers 4 kW of rated output power, 5 kVA apparent, from a 48 V battery bank to a 110-127 V AC output, in pure sine wave, with a 15 ms transfer time between utility and battery. The LV designation shows in those AC figures: nominal input 110-120 V, output 110-127 V, wired L-N. The low-frequency, transformer-based design carries twice rated load for 5 seconds and is motor-start capable, so pumps and compressors start without tripping it. AC input accepts 80-140 V in appliance mode and 90-140 V in UPS mode at 50/60 Hz, passing through up to 63 A; with no battery connected there is no pass-through. Charging is three-stage - boost CC, boost CV, float - up to 50 A, at 57.6 V bulk and 54.4 V float, across a 42-63 V battery window covering AGM, flooded, lithium-ion and self-defined profiles. RS485 carries BMS data, up to 9 units run in parallel, and line-mode efficiency is above 95%. The IP21 chassis measures 494 x 420 x 195 mm and weighs 31.35 kg net. We are an authorised Felicity Solar distributor and supply the IVPS5048P1G1-LV from our own stock.
Specifications last updated 23 July 2026
Felicity Solar IVPS5048P1G1-LV 4kW Single-Phase Inverter / Charger full specifications
Electrical
| AC Output Voltage | 110-127 V |
|---|---|
| AC Wiring Mode | L-N |
| Backup Rated Output Power | 4 kW |
| Battery Inputs | 1 |
| Battery Type | AGM, Flooded, Li-Ion, Self-Defined |
| Battery Voltage Range | 42-63 V |
| Bulk Charging Voltage | 57.6 V |
| Charge Algorithm | Three-Stage: Boost CC, Boost CV, Float |
| Float Charging Voltage | 54.4 V |
| High DC Input Recovery Voltage | 62 V |
| High Frequency Disconnect | 65 Hz |
| High Frequency Reconnect | 63 Hz |
| High Line Disconnect Voltage | 140 V |
| High Line Reconnect Voltage | 135 V |
| Input Voltage Range | 80-140 V |
| Input Voltage Range (UPS Mode) | 90-140 V |
| Input Voltage Waveform | Sinusoidal (utility or generator) |
| Line Mode Efficiency | >95 % |
| Line Mode Output Waveform | Same As Input Waveform |
| Low DC Shutdown (<50% Load) | 43 V |
| Low DC Shutdown (>50% Load) | 42 V |
| Low Frequency Disconnect | 40 Hz |
| Low Frequency Reconnect | 42 Hz |
| Low Line Disconnect (Appliance Mode) | 80 V |
| Low Line Disconnect (UPS Mode) | 90 V |
| Low Line Reconnect (Appliance Mode) | 85 V |
| Low Line Reconnect (UPS Mode) | 95 V |
| Low-Battery Recovery (<50% Load) | 47 V |
| Low-Battery Recovery (>50% Load) | 46 V |
| Max AC Charge Current | 50 A |
| Max AC Input Voltage | 140 V |
| Max AC Pass-Through Current | 63 A |
| Max Charging Current | 50 A |
| Max Charging Voltage | 61.0 V |
| Max Efficiency | 90 % |
| Motor Start Capable | Yes |
| Nominal AC Input Voltage | 110-120 V |
| Nominal DC Input Voltage | 48 V |
| Nominal Input Frequency | 50/60 Hz |
| Output Frequency | 50/60 Hz |
| Output Short-Circuit Protection | Yes |
| Output Voltage Regulation | 5 % |
| Output Voltage Waveform | Pure Sine Wave |
| Overload Protection | Air Switch Protection |
| Overload Trip Time (>105% Load) | 10 s |
| Overload Trip Time (>150% Load) | 5 s |
| Pass-Through Without Battery | No |
| Phase | Single Phase |
| Protection | Over Charge Protection, Over Discharge Protection, Overload Protection, Output Short Circuit Protection, Over Temperature Protection |
| Rated Apparent Output Power | 5 kVA |
| Rated Output Power | 4 kW |
| Short-Circuit Protection (Line Mode) | Air Switch Protection |
| Start-Up Voltage | 46 V |
| Surge Rating | 2*rated (5s) |
| Transfer Time | 15 ms |
Mechanical
| BMS Communication | RS485 |
|---|---|
| Communication Interface | RS232, RS485 |
| Display | LCD, LED |
| Gross Weight | 35.05 kg |
| Net Weight | 31.35 kg |
| Package Dimensions | 607 x 540 x 290 mm |
| Parallel Capability | 9 |
| Topology | Low-Frequency (transformer-based) |
Environmental
| Cooling | Intelligent Air Cooling |
|---|---|
| IP Rating | IP21 |
| Operating Temperature Range | 0-40 °C |
| Storage Temperature | -15 to 60 °C |
Troubleshooting & error codes
Looking up an error code on this FelicityESS IVPS3524P1G1-LV? Browse the full list of codes for this device, with the cause and recommended fix for each.
View error codes for this device →Related Products

Felicity Solar IVPS3524P1G1-LV 2.8kW Single-Phase Inverter / Charger
- Rated Output Power:2.8 kW
- Max Efficiency:90 %

Felicity Solar IVPS10048P2G1 8000W Inverter / Charger
- Rated Output Power (Va):10000VA
- Rated Output Power (W):8000W

Felicity Solar IVPS7548P2G1 6000W Inverter / Charger
- Rated Output Power (Va):7500VA
- Rated Output Power (W):6000W

Felicity Solar IVPS5024 4kW Single-Phase Inverter / Charger
- Rated Output Power:4 kW
- Max Efficiency:90 %
Related Articles
Felicity Inverter Error Codes: Complete Guide for All Models
Error 15 = output short, 34 = heavy overload, 24 = output voltage low, 27 = battery disconnected, 01 = overload — the real IVPS meanings and fixes.
Read: Felicity Inverter Error Codes: Complete Guide for All Models →Can I Install a Solar Inverter Outside? What IP21, IP31 and IP65 Really Mean
Twenty-five Felicity inverters are IP21 and every SCCM charge controller says indoor wall-mount. IP20, IP21 and IP31 are indoor ratings, and the first digit - the dust one - is the half nobody reads. Here is which listing carries which.
Read: Can I Install a Solar Inverter Outside? What IP21, IP31 and IP65 Really Mean →How to Run a Whole House on Solar in Khartoum
An off-grid house is sized by surge, battery energy and charge current - and the surge row is the one that starts your fridge and your pump. Here are the published figures across the Felicity inverters and batteries, with the arithmetic to use them.
Read: How to Run a Whole House on Solar in Khartoum →