10000VA rated, 8000W continuous
Rated 10000VA and 8000W continuous from a 48V nominal DC input.

A 48V inverter/charger holding 8000W continuous from a 10000VA rating, with split-phase 110/120Vac±5% output on HOT1-N or HOT2-N and 90% peak efficiency.
In stock
The Felicity Solar IVPS10048P2G1 is a 48V off-grid inverter and charger rated 10000VA and 8000W, holding a 20000VA surge for 5 seconds and charging a battery bank at up to 80A. It gives split-phase 110/120Vac±5% between HOT1-N or HOT2-N, regulated to ±5%rms, and transfers between utility and battery in 15ms (typical). Utility charging accepts 90-280Vac, disconnecting at 170±7Vac (UPS) or 90±7Vac (APL) on the low side and 280±7Vac on the high side; output is a pure sine wave and synchronises with input voltage in line mode. Battery settings cover 57.6V boost and 54.4V float on AGM, 58.4V and 55.2V on flooded, and 61.0V maximum on lithium, starting from 46V and shutting down at 43Vdc below 50% load. Peak efficiency is 90%, a 63A overcurrent protector guards the grid side, and the unit does not pass utility through without a battery. It measures 584 x 420 x 195 mm, weighs 67.7 kg gross and runs from 0°C~40°C. We are an authorised Felicity Solar distributor and supply the IVPS10048P2G1 from our own stock; warranty 2 Years.
Specifications last updated 23 July 2026
| Battery | 0₁ |
|---|---|
| Power | 0₁ |
| BMS communication | 24V model(default 27.0V) bm5 6 bmS |
| Capable of Starting Electric | Yes |
| Efficiency(Line mode) | >95% |
| Max. Bypass Overload Current | 30A AC63A |
| Nominal Output Frequency(Hz) | 50±0.3Hz/60±0.3Hz(adjustable) backlight will go out after 60s. |
| Output | split-phase system, make sure no "PAL", 3P1, 3P2 |
| Output Frequency | 50Hz |
| Output voltage | 25.0V to 31.5V. Increment of |
| Power derating | 216-06 221 |
| Rated Output Power (VA) | 10000VA |
| Rated Output Power (W) | 8000W |
| Nominal DC Input Voltage | 48V |
| Input Voltage Waveform | Sinusoidal (utility or generator) |
| Terminal Connection | HOT1-HOT2 |
| Nominal Input Voltage | 220Vac |
| Low Line Disconnect | 170±7Vac (UPS) / 90±7Vac (APL) |
| Low Line Re-connect AC Input Range | 180±7Vac (UPS) / 100±7Vac (APL) |
| High Line Disconnect | 280±7Vac |
| High Line Re-connect | 270±7Vac |
| Max AC Input Voltage | 280Vrms |
| Nominal Input Frequency | 50Hz/60Hz |
| Low Line Frequency Disconnect | 40±1Hz |
| Low Line Frequency Re-connect | 42±1Hz |
| High Line Frequency Disconnect | 65±1Hz |
| High Line Frequency Re-connect | 63±1Hz |
| Line Mode Output Waveform | Synchronize with input voltage |
| Over-Load Protection | Air switch protection |
| Efficiency (Line mode) | ≥95% |
| Transfer Time (AC to DC) | 15ms (typical) |
| Transfer Time (DC to AC) | 15ms (typical) / 30ms (special) |
| Pass Through Without Battery | No |
| Overcurrent Protector (grid) | 63A |
| Input Voltage Range (utility charge) | 90-280Vac |
| Max Charge Current | 80A |
| Charge Current Regulation | 0-80A |
| Charger Short Circuit | 63A |
| Over Charge Protection | Yes |
| Output Voltage Waveform | Pure sine wave |
| Nominal Output Voltage | 220/240Vac±5% (HOT1-HOT2) |
| Split-Phase Output Voltage | 110/120Vac±5% (HOT1-N or HOT2-N) |
| Nominal Output Frequency (Hz) | 50±0.3Hz / 60±0.3Hz (adjustable) |
| Output Voltage Regulation | ±5%rms |
| Peak Efficiency | 90% |
| Inverter Over-Load Protection (SMPS load) | 5s@≥150% load; 10s@105%~150% load |
| Surge Rating | 20000VA for 5 seconds |
| Capable of Starting Electric Motor | Yes |
| Output Short Circuit Protection | Yes |
| Min DC Starting Voltage | 46V |
| Low Battery Alarm | 46Vdc (load < 50%) / 44Vdc (load ≥ 50%) |
| Low Battery Recovery | 47Vdc (load < 50%) / 46Vdc (load ≥ 50%) |
| Low DC Input Shut-down | 43Vdc (load < 50%) / 42Vdc (load ≥ 50%) |
| High DC Input Alarm / Fault | 63Vdc±0.4V |
| High DC Input Recovery | 62Vdc±0.4V |
| Boost Charging Voltage (AGM) | 57.6V |
| Float Charging Voltage (AGM) | 54.4V |
| Boost Charging Voltage (Flooded) | 58.4V |
| Float Charging Voltage (Flooded) | 55.2V |
| Self-Defined Charging Voltage (max) | 61.0V |
| Lithium Charging Voltage (max) | 61.0V |
| Product Dimension | 584x420x195mm |
|---|---|
| Package Dimension | 670x470x355mm |
| Gross Weight | 67.7 kg |
| Operating temperature | 0°C~40°C |
|---|---|
| Storage temperature | -15°C~60°C |
Looking up an error code on this FelicityESS IVPS3524P1G1-LV? Browse the full list of codes for this device, with the cause and recommended fix for each.
View error codes for this device →



Error 15 = output short, 34 = heavy overload, 24 = output voltage low, 27 = battery disconnected, 01 = overload — the real IVPS meanings and fixes.
Read: Felicity Inverter Error Codes: Complete Guide for All Models →Twenty-five Felicity inverters are IP21 and every SCCM charge controller says indoor wall-mount. IP20, IP21 and IP31 are indoor ratings, and the first digit - the dust one - is the half nobody reads. Here is which listing carries which.
Read: Can I Install a Solar Inverter Outside? What IP21, IP31 and IP65 Really Mean →An off-grid house is sized by surge, battery energy and charge current - and the surge row is the one that starts your fridge and your pump. Here are the published figures across the Felicity inverters and batteries, with the arithmetic to use them.
Read: How to Run a Whole House on Solar in Khartoum →10000VA and 8000W. The IVPS10048P2G1 is rated 10000VA apparent power and 8000W continuous, and carries a 20000VA surge for 5 seconds, which is why it is rated as capable of starting an electric motor. Peak efficiency is 90%.
48V nominal DC, charging at up to 80A and regulated across 0-80A. It starts from 46V, alarms at 46Vdc below 50% load or 44Vdc at 50% load and above, and shuts down at 43Vdc / 42Vdc. Lithium charging tops out at 61.0V; AGM boost is 57.6V and float 54.4V.
584 x 420 x 195 mm and 67.7 kg gross. Packaged it measures 670x470x355mm. The unit operates from 0°C~40°C and is stored between -15°C~60°C.
90-280Vac is the accepted utility charging range, and the input waveform is sinusoidal from utility or generator. Nominal input is 220Vac at 50Hz/60Hz, transfer takes 15ms (typical), a 63A overcurrent protector guards the grid side, and the unit does not pass utility through without a battery connected.