2.8 kW at 110-127 V
Rated output is 2.8 kW single phase, with the same 2.8 kW held on the backup output as a pure sine wave regulated within 5%.

A 2.8 kW single-phase inverter/charger built for 120 V supplies: 110-127 V output, an 80-140 V input window, 40 A three-stage charging on a 24 V bank, and up to eight units in parallel.
In stock
The Felicity Solar IVPS3524P1G1-LV is a single-phase inverter/charger rated 2.8 kW, holding the same 2.8 kW on its backup output. It runs a 24 V battery bank between 21 V and 31.5 V, puts out 110-127 V at 50/60 Hz on an L-N connection, accepts 80-140 V from utility or generator, and transfers in 15 ms. The -LV suffix is written into those AC figures: nominal input is 110-120 V, the appliance-mode window runs 80-140 V, and the unit holds on down to 80 V before disconnecting, reconnecting at 85 V, so a soft 120 V supply keeps feeding loads. UPS mode tightens the window to 90-140 V. Charging is three-stage - boost CC, boost CV, float - at up to 40 A, 28.8 V bulk and 27.2 V float, across AGM, flooded, Li-Ion and self-defined banks, with a BMS link over RS485. The low-frequency transformer build weighs 27.7 kg net, starts motors, carries twice rated load for 5 s, and parallels to eight units. An overcurrent protector handles overload, alongside over-charge, over-discharge, output short-circuit and over-temperature protection. Warranty: 2 Years. We are an authorised Felicity Solar distributor and supply the IVPS3524P1G1-LV from our own stock.
Specifications last updated 23 July 2026
| AC Output Voltage | 110-127 V |
|---|---|
| AC Wiring Mode | L-N |
| Backup Rated Output Power | 2.8 kW |
| Battery Inputs | 1 |
| Battery Type | AGM, Flooded, Li-Ion, Self-Defined |
| Battery Voltage Range | 21-31.5 V |
| Bulk Charging Voltage | 28.8 V |
| Charge Algorithm | Three-Stage: Boost CC, Boost CV, Float |
| Float Charging Voltage | 27.2 V |
| High DC Input Recovery Voltage | 31 V |
| High Frequency Disconnect | 65 Hz |
| High Frequency Reconnect | 63 Hz |
| High Line Disconnect Voltage | 140 V |
| High Line Reconnect Voltage | 135 V |
| Input Voltage Range | 80-140 V |
| Input Voltage Range (UPS Mode) | 90-140 V |
| Input Voltage Waveform | Sinusoidal (utility or generator) |
| Line Mode Efficiency | >95 % |
| Line Mode Output Waveform | Same As Input Waveform |
| Low DC Shutdown (<50% Load) | 21.5 V |
| Low DC Shutdown (>50% Load) | 21 V |
| Low Frequency Disconnect | 40 Hz |
| Low Frequency Reconnect | 42 Hz |
| Low Line Disconnect (Appliance Mode) | 80 V |
| Low Line Disconnect (UPS Mode) | 90 V |
| Low Line Reconnect (Appliance Mode) | 85 V |
| Low Line Reconnect (UPS Mode) | 95 V |
| Low-Battery Recovery (<50% Load) | 23.5 V |
| Low-Battery Recovery (>50% Load) | 23 V |
| Max AC Charge Current | 40 A |
| Max AC Input Voltage | 140 V |
| Max AC Pass-Through Current | 50 A |
| Max Charging Current | 40 A |
| Max Charging Voltage | 31.5 V |
| Max Efficiency | 90 % |
| Motor Start Capable | Yes |
| Nominal AC Input Voltage | 110-120 V |
| Nominal DC Input Voltage | 24 V |
| Nominal Input Frequency | 50/60 Hz |
| Output Frequency | 50/60 Hz |
| Output Short-Circuit Protection | Yes |
| Output Voltage Regulation | 5 % |
| Output Voltage Waveform | Pure Sine Wave |
| Overload Protection | Overcurrent Protector |
| Overload Trip Time (>105% Load) | 10 s |
| Overload Trip Time (>150% Load) | 5 s |
| Pass-Through Without Battery | No |
| Phase | Single Phase |
| Protection | Over Charge Protection, Over Discharge Protection, Overload Protection, Output Short Circuit Protection, Over Temperature Protection |
| Rated Apparent Output Power | 3.5 kVA |
| Rated Output Power | 2.8 kW |
| Short-Circuit Protection (Line Mode) | Overcurrent Protector |
| Start-Up Voltage | 23 V |
| Surge Rating | 2*rated (5s) |
| Transfer Time | 15 ms |
| BMS Communication | RS485 |
|---|---|
| Communication Interface | RS232, RS485 |
| Display | LCD, LED |
| Gross Weight | 30.8 kg |
| Net Weight | 27.7 kg |
| Package Dimensions | 552 x 508 x 290 mm |
| Parallel Capability | 8 |
| Topology | Low-Frequency (transformer-based) |
| Cooling | Intelligent Air Cooling |
|---|---|
| IP Rating | IP21 |
| Operating Temperature Range | 0-40 °C |
| Storage Temperature | -15 to 60 °C |
Looking up an error code on this FelicityESS IVPS3524P1G1-LV? Browse the full list of codes for this device, with the cause and recommended fix for each.
View error codes for this device →



Error 15 = output short, 34 = heavy overload, 24 = output voltage low, 27 = battery disconnected, 01 = overload — the real IVPS meanings and fixes.
Read: Felicity Inverter Error Codes: Complete Guide for All Models →Twenty-five Felicity inverters are IP21 and every SCCM charge controller says indoor wall-mount. IP20, IP21 and IP31 are indoor ratings, and the first digit - the dust one - is the half nobody reads. Here is which listing carries which.
Read: Can I Install a Solar Inverter Outside? What IP21, IP31 and IP65 Really Mean →An off-grid house is sized by surge, battery energy and charge current - and the surge row is the one that starts your fridge and your pump. Here are the published figures across the Felicity inverters and batteries, with the arithmetic to use them.
Read: How to Run a Whole House on Solar in Khartoum →2.8 kW, single phase, and the same 2.8 kW stays available on the backup output. The waveform is a pure sine wave at 110-127 V and 50/60 Hz, regulated within 5%, and the unit carries twice rated load for 5 s to start motors.
24 V. The bank works anywhere from 21 V to 31.5 V on the single battery input. AGM, flooded, Li-Ion and self-defined types are supported, charged in three stages - boost CC, boost CV, float - at up to 40 A with 28.8 V bulk and 27.2 V float. It starts at 23 V and talks to a BMS over RS485.
80-140 V is the appliance-mode input window, so it holds on until 80 V and reconnects at 85 V; UPS mode uses 90-140 V. Input may be a sinusoidal utility or generator waveform at 50/60 Hz, and switching to battery takes 15 ms.
27.7 kg net and 30.8 kg gross. The unit measures 440 x 391 x 195 mm and ships in a 552 x 508 x 290 mm carton. It is a low-frequency, transformer-based build rated IP21 with intelligent air cooling, for 0-40 °C operation and -15 to 60 °C storage.