The Felicity Solar IVBM8048P1G1 is an 8 kW single-phase off-grid inverter running on a 48 V battery bank, rated 8 kW / 8 kVA at 230 V with 40 A maximum output current. Peak efficiency is 94.5%, above 95% in line mode.
- Rated Output Power: 8 kW
- Max Efficiency: 94.5 %
- Max PV Input Power: 5+5 kW
- Battery Voltage Range: 42-60 V
Models in the IVBM8048P1G1 – IVBM10048P1G1 family
- 8 kW
- 10 kW
What sets the IVBM8048P1G1 apart from the other model in the family: Backup Max Output Current 40 A; Backup Rated Output Power 8 kW; Max AC Charge Current 150 A; Max AC Pass-Through Current 53 A; Max Charging Current 150 A; Max Inverter/Rectifier Current 40 A; Max Output Current 40 A; Max PV Input Power 5+5 kW.
In stock
- Delivered within 3 business days, door to door, to every market we serve.
- Dispatched the same business day for an order placed before 21:00 (Dubai time), or the next business day after.
- Delivery charge: free
- 2-year warranty
Felicity Solar IVBM8048P1G1 8kW Single-Phase Off-Grid Solar Inverter features
94.5% peak efficiency and above 95% in line mode, with 10 ms UPS transfer time
150 A maximum charging current from solar, from the grid, or from a 32 A generator input
Single MPPT tracking 100-450 V, two strings at 20+20 A, 450 V maximum PV voltage
48 V nominal battery over a 42-60 V range: AGM, flooded, lithium-ion or self-defined, with RS485 and CAN BMS
IP65 wall-mounted enclosure, 24.3 kg net, 490 x 189.2 x 525 mm, up to 6 units in parallel
About the Felicity Solar IVBM8048P1G1 8kW Single-Phase Off-Grid Solar Inverter
The Felicity Solar IVBM8048P1G1 is an 8 kW single-phase off-grid solar inverter built around a 48 V battery bank. It delivers 8 kW / 8 kVA of continuous output at 230 V and 50/60 Hz, up to 40 A, at a peak efficiency of 94.5% and above 95% in line mode, with a 10 ms transfer time in UPS mode. A single MPPT tracker works from 100-450 V and takes two strings at 20+20 A, while charging reaches 150 A from solar, from the grid, or from a generator drawing up to 32 A. The low-frequency topology holds twice rated power for 5 seconds and starts motor loads. Battery support covers AGM, flooded, lithium-ion and self-defined profiles across 42-60 V, with RS485 and CAN BMS communication, built-in Wi-Fi monitoring and an LCD and LED display. The IP65 wall-mounted unit weighs 24.3 kg net, measures 490 x 189.2 x 525 mm, and runs from 0 to 50 C. Six units parallel with a battery fitted. We supply it as an authorised Felicity Solar distributor.
Specifications last updated 23 July 2026
Felicity Solar IVBM8048P1G1 8kW Single-Phase Off-Grid Solar Inverter full specifications
Electrical(70)
| AC Output Voltage | 230 V |
|---|---|
| AC Wiring Mode | L+N+PE |
| Backup Max Output Current | 40 A |
| Backup Rated Output Power | 8 kW |
| Battery Inputs | 1 |
| Battery Type | AGM, Flooded, Li-Ion, Self-Defined |
| Battery Voltage Range | 42-60 V |
| Bulk Charging Voltage | 56.4 V |
| Charge Algorithm | Three-Stage: Boost CC, Boost CV, Float |
| Float Charging Voltage | 54 V |
| High DC Input Recovery Voltage | 56.4 V |
| High Frequency Disconnect | 65 Hz |
| High Frequency Reconnect | 63 Hz |
| High Line Disconnect Voltage | 280 V |
| High Line Reconnect Voltage | 270 V |
| Input Voltage Range | 90-280 V |
| Input Voltage Range (UPS Mode) | 170-280 V |
| Input Voltage Waveform | Sinusoidal (utility or generator) |
| Line Mode Efficiency | >95 % |
| Line Mode Output Waveform | Same As Input Waveform |
| Low DC Shutdown (<50% Load) | 43 V |
| Low DC Shutdown (>50% Load) | 42 V |
| Low Frequency Disconnect | 40 Hz |
| Low Frequency Reconnect | 42 Hz |
| Low Line Disconnect (Appliance Mode) | 90 V |
| Low Line Disconnect (UPS Mode) | 170 V |
| Low Line Reconnect (Appliance Mode) | 100 V |
| Low Line Reconnect (UPS Mode) | 180 V |
| Low-Battery Recovery (<50% Load) | 47 V |
| Low-Battery Recovery (>50% Load) | 46 V |
| MPPT Trackers | 1 |
| MPPT Voltage Range | 100-450 V |
| Max AC Charge Current | 150 A |
| Max AC Input Voltage | 280 V |
| Max AC Pass-Through Current | 53 A |
| Max Charging Current | 150 A |
|---|---|
| Max Charging Voltage | 60 V |
| Max Efficiency | 94.5 % |
| Max Generator Input Current | 32 A |
| Max Inverter/Rectifier Current | 40 A |
| Max Output Current | 40 A |
| Max PV Input Current | 20+20 A |
| Max PV Input Power | 5+5 kW |
| Max PV Voltage | 450 V |
| Max Smart Load Output Current | 40 A |
| Max Solar Charging Current | 150 A |
| Motor Start Capable | Yes |
| Nominal AC Input Voltage | 230 V |
| Nominal DC Input Voltage | 48 V |
| Nominal Input Frequency | 50/60 Hz |
| Output Frequency | 50/60 Hz |
| Output Short-Circuit Protection | Yes |
| Output Voltage Regulation | 5 % |
| Output Voltage Waveform | Pure Sine Wave |
| Overload Protection | Yes |
| Overload Trip Time (>105% Load) | 10 s |
| Overload Trip Time (>150% Load) | 5 s |
| PV Working Voltage Range | 90-450 V |
| Pass-Through Without Battery | Yes |
| Phase | Single Phase |
| Protection | Overload Protection, Over Temperature Protection, Short Circuit Protection |
| Rated Apparent Output Power | 8 kVA |
| Rated Output Power | 8 kW |
| Short-Circuit Protection (Battery Mode) | Electronic Circuit |
| Short-Circuit Protection (Line Mode) | Circuit Breaker |
| Start-Up Voltage | 160 V |
| Strings per MPPT | 2 |
| Surge Rating | 2*rated (5s) |
| Transfer Time (Appliance Mode) | 20 ms |
| Transfer Time (UPS Mode) | 10 ms |
Mechanical(10)
| BMS Communication | RS485, CAN |
|---|---|
| Communication Interface | RS232, RS485, CAN |
| Display | LCD, LED |
| Gross Weight | 28.3 kg |
| Installation Style | Wall-Mounted |
| Monitoring Module | Built-In WiFi |
| Net Weight | 24.3 kg |
| Package Dimensions | 572 x 267 x 597 mm |
| Parallel Capability | 6 (battery required) |
| Topology | Low-Frequency |
Environmental(4)
| Cooling | Intelligent Air Cooling |
|---|---|
| IP Rating | IP65 |
| Operating Temperature Range | 0-50 °C |
| Storage Temperature | -15 to 60 °C |
Downloads & support
Frequently Asked Questions
Is the Felicity IVBM8048P1G1 the 8000 W model?
Yes. The IVBM8048P1G1 is rated 8 kW / 8 kVA, so 8000 W of continuous output at 230 V and 50/60 Hz, with a maximum output current of 40 A and a maximum AC pass-through current of 53 A. Surge capability is twice the rated power for 5 seconds, and the backup rated output power is also 8 kW.
What battery does the IVBM8048P1G1 need?
A 48 V nominal battery bank, usable across a 42-60 V range. AGM, flooded, lithium-ion and self-defined profiles are supported, charged in three stages (boost CC, boost CV, float) at 56.4 V bulk and 54 V float, up to 150 A. BMS communication is over RS485 and CAN.
How many solar panels can I connect to the IVBM8048P1G1?
It has one MPPT tracker with a 100-450 V tracking window, a 450 V maximum PV voltage and two strings per tracker at 20+20 A. PV working voltage range is 90-450 V and the start-up voltage is 160 V, so the array is sized to stay inside those limits.
Can the IVBM8048P1G1 run in parallel or without a battery?
Up to 6 units can run in parallel, and a battery must be connected for parallel operation. The inverter does support AC pass-through without a battery. Transfer time is 10 ms in UPS mode and 20 ms in appliance mode.