Felicity Solar IVBM8048P1G1

InvertersModel IVBM8048P1G1

Felicity Solar IVBM8048P1G1 8kW Single-Phase Off-Grid Solar Inverter

The Felicity Solar IVBM8048P1G1 is an 8 kW single-phase off-grid inverter running on a 48 V battery bank, rated 8 kW / 8 kVA at 230 V with 40 A maximum output current. Peak efficiency is 94.5%, above 95% in line mode.

  • Rated Output Power: 8 kW
  • Max Efficiency: 94.5 %
  • Max PV Input Power: 5+5 kW
  • Battery Voltage Range: 42-60 V

Models in the IVBM8048P1G1 – IVBM10048P1G1 family

What sets the IVBM8048P1G1 apart from the other model in the family: Backup Max Output Current 40 A; Backup Rated Output Power 8 kW; Max AC Charge Current 150 A; Max AC Pass-Through Current 53 A; Max Charging Current 150 A; Max Inverter/Rectifier Current 40 A; Max Output Current 40 A; Max PV Input Power 5+5 kW.

AED 5,500incl. VAT

In stock

  • Delivered within 3 business days, door to door, to every market we serve.
  • Dispatched the same business day for an order placed before 21:00 (Dubai time), or the next business day after.
  • Delivery charge: free
  • 2-year warranty

Felicity Solar IVBM8048P1G1 8kW Single-Phase Off-Grid Solar Inverter features

  • 8 kW / 8 kVA continuous output at 230 V, 50/60 Hz, 40 A maximum output current

  • 94.5% peak efficiency and above 95% in line mode, with 10 ms UPS transfer time

  • 150 A maximum charging current from solar, from the grid, or from a 32 A generator input

  • Single MPPT tracking 100-450 V, two strings at 20+20 A, 450 V maximum PV voltage

  • 48 V nominal battery over a 42-60 V range: AGM, flooded, lithium-ion or self-defined, with RS485 and CAN BMS

  • IP65 wall-mounted enclosure, 24.3 kg net, 490 x 189.2 x 525 mm, up to 6 units in parallel

About the Felicity Solar IVBM8048P1G1 8kW Single-Phase Off-Grid Solar Inverter

The Felicity Solar IVBM8048P1G1 is an 8 kW single-phase off-grid solar inverter built around a 48 V battery bank. It delivers 8 kW / 8 kVA of continuous output at 230 V and 50/60 Hz, up to 40 A, at a peak efficiency of 94.5% and above 95% in line mode, with a 10 ms transfer time in UPS mode. A single MPPT tracker works from 100-450 V and takes two strings at 20+20 A, while charging reaches 150 A from solar, from the grid, or from a generator drawing up to 32 A. The low-frequency topology holds twice rated power for 5 seconds and starts motor loads. Battery support covers AGM, flooded, lithium-ion and self-defined profiles across 42-60 V, with RS485 and CAN BMS communication, built-in Wi-Fi monitoring and an LCD and LED display. The IP65 wall-mounted unit weighs 24.3 kg net, measures 490 x 189.2 x 525 mm, and runs from 0 to 50 C. Six units parallel with a battery fitted. We supply it as an authorised Felicity Solar distributor.

Specifications last updated 23 July 2026

Felicity Solar IVBM8048P1G1 8kW Single-Phase Off-Grid Solar Inverter full specifications

Electrical(70)

AC Output Voltage230 V
AC Wiring ModeL+N+PE
Backup Max Output Current40 A
Backup Rated Output Power8 kW
Battery Inputs1
Battery TypeAGM, Flooded, Li-Ion, Self-Defined
Battery Voltage Range42-60 V
Bulk Charging Voltage56.4 V
Charge AlgorithmThree-Stage: Boost CC, Boost CV, Float
Float Charging Voltage54 V
High DC Input Recovery Voltage56.4 V
High Frequency Disconnect65 Hz
High Frequency Reconnect63 Hz
High Line Disconnect Voltage280 V
High Line Reconnect Voltage270 V
Input Voltage Range90-280 V
Input Voltage Range (UPS Mode)170-280 V
Input Voltage WaveformSinusoidal (utility or generator)
Line Mode Efficiency>95 %
Line Mode Output WaveformSame As Input Waveform
Low DC Shutdown (<50% Load)43 V
Low DC Shutdown (>50% Load)42 V
Low Frequency Disconnect40 Hz
Low Frequency Reconnect42 Hz
Low Line Disconnect (Appliance Mode)90 V
Low Line Disconnect (UPS Mode)170 V
Low Line Reconnect (Appliance Mode)100 V
Low Line Reconnect (UPS Mode)180 V
Low-Battery Recovery (<50% Load)47 V
Low-Battery Recovery (>50% Load)46 V
MPPT Trackers1
MPPT Voltage Range100-450 V
Max AC Charge Current150 A
Max AC Input Voltage280 V
Max AC Pass-Through Current53 A
Max Charging Current150 A
Max Charging Voltage60 V
Max Efficiency94.5 %
Max Generator Input Current32 A
Max Inverter/Rectifier Current40 A
Max Output Current40 A
Max PV Input Current20+20 A
Max PV Input Power5+5 kW
Max PV Voltage450 V
Max Smart Load Output Current40 A
Max Solar Charging Current150 A
Motor Start CapableYes
Nominal AC Input Voltage230 V
Nominal DC Input Voltage48 V
Nominal Input Frequency50/60 Hz
Output Frequency50/60 Hz
Output Short-Circuit ProtectionYes
Output Voltage Regulation5 %
Output Voltage WaveformPure Sine Wave
Overload ProtectionYes
Overload Trip Time (>105% Load)10 s
Overload Trip Time (>150% Load)5 s
PV Working Voltage Range90-450 V
Pass-Through Without BatteryYes
PhaseSingle Phase
ProtectionOverload Protection, Over Temperature Protection, Short Circuit Protection
Rated Apparent Output Power8 kVA
Rated Output Power8 kW
Short-Circuit Protection (Battery Mode)Electronic Circuit
Short-Circuit Protection (Line Mode)Circuit Breaker
Start-Up Voltage160 V
Strings per MPPT2
Surge Rating2*rated (5s)
Transfer Time (Appliance Mode)20 ms
Transfer Time (UPS Mode)10 ms

Mechanical(10)

BMS CommunicationRS485, CAN
Communication InterfaceRS232, RS485, CAN
DisplayLCD, LED
Gross Weight28.3 kg
Installation StyleWall-Mounted
Monitoring ModuleBuilt-In WiFi
Net Weight24.3 kg
Package Dimensions572 x 267 x 597 mm
Parallel Capability6 (battery required)
TopologyLow-Frequency

Environmental(4)

CoolingIntelligent Air Cooling
IP RatingIP65
Operating Temperature Range0-50 °C
Storage Temperature-15 to 60 °C

Downloads & support

Frequently Asked Questions

Is the Felicity IVBM8048P1G1 the 8000 W model?

Yes. The IVBM8048P1G1 is rated 8 kW / 8 kVA, so 8000 W of continuous output at 230 V and 50/60 Hz, with a maximum output current of 40 A and a maximum AC pass-through current of 53 A. Surge capability is twice the rated power for 5 seconds, and the backup rated output power is also 8 kW.

What battery does the IVBM8048P1G1 need?

A 48 V nominal battery bank, usable across a 42-60 V range. AGM, flooded, lithium-ion and self-defined profiles are supported, charged in three stages (boost CC, boost CV, float) at 56.4 V bulk and 54 V float, up to 150 A. BMS communication is over RS485 and CAN.

How many solar panels can I connect to the IVBM8048P1G1?

It has one MPPT tracker with a 100-450 V tracking window, a 450 V maximum PV voltage and two strings per tracker at 20+20 A. PV working voltage range is 90-450 V and the start-up voltage is 160 V, so the array is sized to stay inside those limits.

Can the IVBM8048P1G1 run in parallel or without a battery?

Up to 6 units can run in parallel, and a battery must be connected for parallel operation. The inverter does support AC pass-through without a battery. Transfer time is 10 ms in UPS mode and 20 ms in appliance mode.

Customer reviews