InvertersModel IVEM3048-SALV
Felicity Solar IVEM3048-SALV 3kW Single-Phase Off-Grid Solar Inverter
A 3 kW / 3 kVA single-phase off-grid inverter, the IVEM3048-SALV delivers 127 V at 60 Hz as a pure sine wave from a 48 V battery bank and takes up to 4 kW of PV on its single MPPT tracker.
- Rated Output Power: 3 kW
- Max Efficiency: 93 %
- Max PV Input Power: 4 kW
- Battery Voltage Range: 42-63 V
In stock
- Delivered within 3 business days, door to door, to every market we serve.
- Dispatched the same business day for an order placed before 21:00 (Dubai time), or the next business day after.
- Delivery charge: AED 75
- 2-year warranty
Felicity Solar IVEM3048-SALV 3kW Single-Phase Off-Grid Solar Inverter features
127 V AC output at 60 Hz as a pure sine wave, regulated to within 5%, at up to 30 A of output current
One MPPT tracker taking up to 4 kW of PV at 15 A, a 120-450 V working range, 500 V maximum PV voltage and 100 V start-up
48 V nominal battery bank across a 42-63 V window, charged at up to 60 A with a 56.4 V boost stage and a 54 V float stage
93% peak efficiency and above 95% in line mode, transferring in 20 ms on appliance mode or 10 ms on UPS mode
Wall-mounted IP21 chassis of 440 x 328 x 130 mm at 11.9 kg net, with LCD, built-in WiFi and RS485 BMS communication
About the Felicity Solar IVEM3048-SALV 3kW Single-Phase Off-Grid Solar Inverter
The Felicity Solar IVEM3048-SALV is a 3 kW single-phase off-grid solar inverter that delivers 127 V at 60 Hz from a 48 V battery bank, rated 3 kVA of apparent power, with one MPPT tracker accepting up to 4 kW and 15 A of PV across a 120-450 V working range. The -SALV build is the 127 V, 60 Hz edition: nominal AC input is 127 V, accepted from 65-140 V in appliance mode and 90-140 V in UPS mode, with transfer in 20 ms on appliance mode and 10 ms on UPS mode against a 50 ms general transfer time. Peak efficiency is 93% and line-mode efficiency exceeds 95%. Output is regulated to within 5% at up to 30 A, with 2x rated surge for 5 seconds. Charging runs to 60 A from solar or AC, boosting at 56.4 V and floating at 54 V across AGM, Flooded, Li-Ion and Self-Defined batteries over RS485. The wall-mounted IP21 chassis measures 440 x 328 x 130 mm at 11.9 kg net. The warranty term is 2 Years. We are an authorised Felicity Solar distributor and supply the IVEM3048-SALV from our own stock.
Specifications last updated 17 August 2026
Felicity Solar IVEM3048-SALV 3kW Single-Phase Off-Grid Solar Inverter full specifications
Electrical(68)
| AC Output Voltage | 127 V |
|---|---|
| AC Wiring Mode | L+N+PE |
| Backup Rated Output Power | 3 kW |
| Battery Inputs | 1 |
| Battery Type | AGM, Flooded, Li-Ion, Self-Defined |
| Battery Voltage Range | 42-63 V |
| Bulk Charging Voltage | 56.4 V |
| Charge Algorithm | Three-Stage: Boost CC, Boost CV, Float |
| Float Charging Voltage | 54 V |
| High DC Input Recovery Voltage | 56.4 V |
| High Frequency Disconnect | 65 Hz |
| High Frequency Reconnect | 63 Hz |
| High Line Disconnect Voltage | 140 V |
| High Line Reconnect Voltage | 135 V |
| Input Voltage Range | 65-140 V |
| Input Voltage Range (UPS Mode) | 90-140 V |
| Input Voltage Waveform | Sinusoidal (utility or generator) |
| Line Mode Efficiency | >95 % |
| Line Mode Output Waveform | Same As Input Waveform |
| Low DC Shutdown (<50% Load) | 43 V |
| Low DC Shutdown (>50% Load) | 42 V |
| Low Frequency Disconnect | 47 Hz |
| Low Frequency Reconnect | 49 Hz |
| Low Line Disconnect (Appliance Mode) | 65 V |
| Low Line Disconnect (UPS Mode) | 90 V |
| Low Line Reconnect (Appliance Mode) | 70 V |
| Low Line Reconnect (UPS Mode) | 95 V |
| Low-Battery Recovery (<50% Load) | 47 V |
| Low-Battery Recovery (>50% Load) | 46 V |
| MPPT Trackers | 1 |
| MPPT Voltage Range | 120-450 V |
| Max AC Charge Current | 60 A |
| Max AC Input Voltage | 140 V |
| Max AC Pass-Through Current | 40 A |
| Max Charging Current | 60 A |
|---|---|
| Max Charging Voltage | 60 V |
| Max Efficiency | 93 % |
| Max Inverter/Rectifier Current | 30 A |
| Max Output Current | 30 A |
| Max PV Input Current | 15 A |
| Max PV Input Power | 4 kW |
| Max PV Voltage | 500 V |
| Max Solar Charging Current | 60 A |
| Motor Start Capable | Yes |
| Nominal AC Input Voltage | 127 V |
| Nominal DC Input Voltage | 48 V |
| Nominal Input Frequency | 60 Hz |
| Output Frequency | 60 Hz |
| Output Short-Circuit Protection | Yes |
| Output Voltage Regulation | 5 % |
| Output Voltage Waveform | Pure Sine Wave |
| Overload Protection | Yes |
| Overload Trip Time (>105% Load) | 10.5 s |
| Overload Trip Time (>150% Load) | 5.5 s |
| PV Working Voltage Range | 120-450 V |
| Pass-Through Without Battery | Yes |
| Phase | Single Phase |
| Protection | Overload Protection, Over Temperature Protection, Short Circuit Protection |
| Rated Apparent Output Power | 3 kVA |
| Rated Output Power | 3 kW |
| Short-Circuit Protection (Battery Mode) | Electronic Circuit |
| Short-Circuit Protection (Line Mode) | Circuit Breaker |
| Start-Up Voltage | 100 V |
| Strings per MPPT | 1 |
| Surge Rating | 2*rated (5s) |
| Transfer Time | 50 ms |
| Transfer Time (Appliance Mode) | 20 ms |
| Transfer Time (UPS Mode) | 10 ms |
Mechanical(10)
| BMS Communication | RS485 |
|---|---|
| Display | LCD |
| Gross Weight | 14.2 kg |
| Installation Style | Wall-Mounted |
| Monitoring Module | Built-In WiFi |
| Net Weight | 11.9 kg |
| Package Dimensions | 542 x 430 x 224 mm |
| Parallel Capability | No |
| Safety Standard | IEC 62109-1, IEC 62109-2 |
| Topology | High-Frequency |
Environmental(4)
| Cooling | Intelligent Air Cooling |
|---|---|
| IP Rating | IP21 |
| Operating Temperature Range | -10 to 50 °C |
| Storage Temperature | -15 to 60 °C |
Certifications(2)
- IEC 62109-1
- IEC 62109-2
Downloads & support
Frequently Asked Questions
What AC output does the IVEM3048-SALV produce?
127 V at 60 Hz, single phase, as a pure sine wave regulated to within 5% and wired L+N+PE. Maximum output current is 30 A, with 2x rated surge for 5 seconds, and the unit is rated 3 kW of real power and 3 kVA of apparent power.
How much solar can the IVEM3048-SALV take?
4 kW is the maximum PV input power, gathered by one MPPT tracker on a single string at up to 15 A. The working voltage range is 120-450 V, maximum PV voltage is 500 V and start-up voltage is 100 V.
Which batteries does the IVEM3048-SALV support?
48 V nominal on one battery input, usable across a 42-63 V range, covering AGM, Flooded, Li-Ion and Self-Defined types. Three-stage charging reaches 60 A with a 56.4 V boost and a 54 V float, and RS485 carries BMS communication.
How fast does the IVEM3048-SALV switch over, and what warranty does it carry?
20 ms in appliance mode and 10 ms in UPS mode, against a 50 ms general transfer time, with the AC input window at 65-140 V for appliance mode and 90-140 V for UPS mode. The warranty term is 2 Years, and the unit is built to IEC 62109-1 and IEC 62109-2.