60-500 V MPPT window, 60 V start-up
The single MPPT tracker wakes at a 60 V start-up voltage and tracks to the 500 V maximum PV voltage, so a long string and a short one both work.

InvertersModel IVEM4024-II
A 4 kVA single-phase off-grid inverter for 24 V systems: a 60-500 V MPPT window, 27 A of PV input current, 120 A charging and a 10.4 kg high-frequency chassis with LCD and built-in WiFi.
What sets the IVEM4024-II apart from the other model in the family: Backup Rated Output Power 4 kW; Line Mode Efficiency >93 %; MPPT Voltage Range 60-500 V; Max AC Charge Current 120 A; Max Charging Current 120 A; Max PV Input Current 27 A; Max PV Input Power 6 kW; Max Solar Charging Current 120 A.
In stock
The single MPPT tracker wakes at a 60 V start-up voltage and tracks to the 500 V maximum PV voltage, so a long string and a short one both work.
Maximum PV input current is 27 A and maximum PV input power is 6 kW, giving the 4 kVA inverter room to oversize its array.
Charging reaches 120 A from solar or from AC into a 21-31.5 V bank at 24 V nominal, held at 28.2 V boost and 27 V float.
Rated apparent power is 4 kVA with 4 kW backup, delivered as a pure sine wave at 230 V single phase, 50/60 Hz, up to 30 A and 2x rated for 5 s.
Transfer time is 50 ms and the AC input holds from 90 to 280 V, with 5% voltage regulation, 30 A maximum inverter/rectifier current and overload, over-temperature and short-circuit protection.
Net weight is 10.4 kg and gross weight 11.9 kg in a 507 x 387 x 197 mm package, with an IP21 rating, LCD, built-in WiFi and RS485 BMS communication.
The Felicity Solar IVEM4024-II is a 4 kVA single-phase off-grid solar inverter for a 24 V battery bank. One MPPT tracker works from a 60 V start-up across a 60-500 V window, accepting 27 A and 6 kW of PV, while charging reaches 120 A from either solar or AC. Output is a pure sine wave at 230 V, 50/60 Hz, regulated to 5% and capped at 30 A, with a surge rating of 2x rated for 5 s and a 50 ms transfer when the 90-280 V AC input falls away. The three-stage charger holds 28.2 V boost and 27 V float across a 21-31.5 V battery window, drives AGM, Flooded, Li-Ion and Self-Defined chemistries through one battery input, and talks to the BMS over RS485. Maximum efficiency is 93%, with line mode listed at >93%. The high-frequency chassis weighs 10.4 kg net and 11.9 kg gross, ships in a 507 x 387 x 197 mm package, carries an LCD and built-in WiFi, and is rated IP21 for -10 to 50 °C. It is certified to IEC 62109-1 and IEC 62109-2. We are the authorised Felicity Solar distributor and supply it with a 2 Years warranty.
Specifications last updated 23 March 2026
| AC Output Voltage | 230 V |
|---|---|
| AC Wiring Mode | L+N+PE |
| Backup Rated Output Power | 4 kW |
| Battery Inputs | 1 |
| Battery Type | AGM, Flooded, Li-Ion, Self-Defined |
| Battery Voltage Range | 21-31.5 V |
| Bulk Charging Voltage | 28.2 V |
| Charge Algorithm | Three-Stage: Boost CC, Boost CV, Float |
| Float Charging Voltage | 27 V |
| High Frequency Disconnect | 65 Hz |
| High Frequency Reconnect | 63 Hz |
| High Line Disconnect Voltage | 280 V |
| High Line Reconnect Voltage | 270 V |
| Input Voltage Range | 90-280 V |
| Input Voltage Range (UPS Mode) | 170-280 V |
| Line Mode Efficiency | >93 % |
| Low Frequency Disconnect | 40 Hz |
| Low Frequency Reconnect | 42 Hz |
| Low Line Disconnect (Appliance Mode) | 90 V |
| Low Line Disconnect (UPS Mode) | 170 V |
| Low Line Reconnect (Appliance Mode) | 100 V |
| Low Line Reconnect (UPS Mode) | 180 V |
| MPPT Trackers | 1 |
| MPPT Voltage Range | 60-500 V |
| Max AC Charge Current | 120 A |
| Max AC Input Voltage | 280 V |
| Max AC Pass-Through Current | 40 A |
| Max Charging Current | 120 A |
| Max Efficiency | 93 % |
| Max Inverter/Rectifier Current | 30 A |
|---|---|
| Max Output Current | 30 A |
| Max PV Input Current | 27 A |
| Max PV Input Power | 6 kW |
| Max PV Voltage | 500 V |
| Max Solar Charging Current | 120 A |
| Motor Start Capable | Yes |
| Nominal AC Input Voltage | 230 V |
| Nominal DC Input Voltage | 24 V |
| Nominal Input Frequency | 50/60 Hz |
| Output Frequency | 50/60 Hz |
| Output Short-Circuit Protection | Yes |
| Output Voltage Regulation | 5 % |
| Output Voltage Waveform | Pure Sine Wave |
| Overload Protection | Yes |
| Overload Trip Time (>105% Load) | 10.5 s |
| Overload Trip Time (>120% Load) | 7.5 s |
| Overload Trip Time (>150% Load) | 5.5 s |
| Overload Trip Time (>200% Load) | 0.2 s |
| PV Working Voltage Range | 60-500 V |
| Pass-Through Without Battery | Yes |
| Phase | Single Phase |
| Protection | Overload Protection, Over Temperature Protection, Short Circuit Protection |
| Rated Apparent Output Power | 4 kVA |
| Rated Output Power | 4 kW |
| Start-Up Voltage | 60 V |
| Strings per MPPT | 1 |
| Surge Rating | 2*rated (5s) |
| Transfer Time | 50 ms |
| BMS Communication | RS485 |
|---|---|
| Display | LCD |
| Gross Weight | 11.9 kg |
| Monitoring Module | Built-In WiFi |
| Net Weight | 10.4 kg |
| Package Dimensions | 507 x 387 x 197 mm |
| Parallel Capability | No |
| Safety Standard | IEC 62109-1, IEC 62109-2 |
| Topology | High-Frequency |
| Cooling | Intelligent Air Cooling |
|---|---|
| IP Rating | IP21 |
| Operating Temperature Range | -10 to 50 °C |
| Storage Temperature | -15 to 60 °C |
60-500 V is the MPPT working window, opened by a 60 V start-up voltage and closed by the 500 V maximum PV voltage. The single tracker takes up to 27 A of PV input current and 6 kW of PV input power.
120 A is the maximum charging current, available from solar or from AC. The charger holds 28.2 V boost and 27 V float across a 21-31.5 V bank at 24 V nominal, supports AGM, Flooded, Li-Ion and Self-Defined batteries through one battery input, and reaches the BMS over RS485.
10.4 kg net and 11.9 kg gross, in a 507 x 387 x 197 mm package. The chassis is rated IP21 with intelligent air cooling, operates from -10 to 50 °C and stores from -15 to 60 °C, so it belongs indoors in a ventilated space.
4 kVA rated apparent power and 4 kW backup power, as a pure sine wave at 230 V single phase, 50/60 Hz, regulated to 5% and capped at 30 A. Surge is 2x rated for 5 s, transfer takes 50 ms when the 90-280 V AC input drops, maximum efficiency is 93%, and this model is not parallel capable.