Fault

C01

Battery overvoltage.

17 Devices that report this code
C01Battery overvoltage.Fault
Description

Battery overvoltage fault. LED pattern: LED1 FLASH, LED2 OFF, LED3 OFF, LED4 OFF (with FAULT mode: GREEN OFF, RED ON).

Recommended fix

Restart the unit. if the error persists, contact the repair center.

Source:Felicitysolar FLA12100 12.5Kwh Battery Energy Storage System User Manual.pdf · page 1
C01Battery overvoltage.Faulthigh
Description

Total battery pack voltage exceeded the upper limit.

Recommended fix

Restart the unit. if the error persists, contact the repair center.

Source:Felicitysolar FLA48200 48V 200Ah 10kWh Lithium Phosphate Battery User Manual.pdf · page 12
C01Battery overvoltage.Critical
Description

BMS reports total battery pack voltage above the upper protection threshold.

Recommended fix

Restart the unit. if the error persists, contact the repair center.

Source:6peluqppy_66a93554057c8.pdf · page 12
C01C01Fault
Description

Battery overvoltage.

Recommended fix

Restart the unit. if the error persists, contact the repair center.

Source:FLA48250-EU_Manual.pdf · page 8
C01Battery overvoltage.Fault
Description

Battery overvoltage protection triggered (pack-level voltage exceeded threshold).

Cause

Battery pack voltage above operating limit (operating range 44.8-57.6V; max charging voltage 57.6V).

Recommended fix

Restart the unit. if the error persists, contact the repair center.

Source:felicitysolar FLA48500 LiFePO4 Battery System for Households User Guide.pdf
C01Batterie-Überspannung.Fault
Description

Battery overvoltage. Total pack voltage exceeded the rated upper protection threshold during charging.

Cause

Total battery pack voltage above rated value (Gesamtspannung des Akkupacks über dem Nennwert). Charging continued past the over-voltage protection point.

Recommended fix

Restart the unit. if the error persists, return to repair centre. (Gerät neu starten; bei Wiederauftreten zur Reparatur einsenden.).

Source:Benutzerhandbuch - Felicity FLS48100SG2.pdf
C01Battery overvoltage.Fault
Description

Battery overvoltage protection triggered (pack-level voltage exceeded threshold).

Cause

Battery pack voltage above operating limit (operating range 44.8-57.6V; max charging voltage 57.6V).

Recommended fix

Restart the unit. if the error persists, contact the repair center.

Source:HE-GF-FLA-48500 Manual_20250327_EN.pdf
C01Battery overvoltage.Fault
Description

Pack-level over-voltage fault displayed on the LCD BMS fault code / flag screen (section 4.3-4.4); fault icon is constant.

Cause

Pack voltage exceeded the BMS over-voltage threshold during charging - typically because the charger's Max. Charging Voltage is set above the recommended 57.6 V (section 2.4 Recommended Settings).

Recommended fix

Restart the unit; if the error persists, contact the repair center. Verify the charger / inverter Max. Charging Voltage and Floating Charging Voltage are set to 57.6 V and pack voltage stays within the 48-57.6 V operating range.

Source:358-010291-07.pdf · page 8
C01Battery overvoltage.Fault
Description

Battery pack overall voltage above protection threshold (BMS protection).

Cause

Total battery voltage has exceeded the BMS upper voltage limit.

Recommended fix

Restart the unit; if the error persists, contact the repair center.

Source:Manual-LPBF48200-H.pdf · page 10
C01C01Fault
Recommended fix

Restart the unit, if the error persists, contact the repair center.

Source:Felicitysolar LPBF48350 17.5kWh 48V Solar Battery Pack with BMS User Guide.pdf
C01Battery overvoltage.Fault
Cause

Battery pack voltage exceeded the upper protection threshold.

Recommended fix

Restart the unit. if the error persists, contact the repair center.

Source:LUX-E-48100LG03-Lithium-Battery-User-Guide.pdf · page 12
C01C01Fault
Recommended fix

Restart the unit. if the error persists, contact the repair center.

Source:LUX-E-48200LG03-Lithium-Battery-User-Guide.pdf · page 12
C01C01Fault
Recommended fix

Restart the unit. if the error persists, contact the repair center.

Source:LUX-E-48230.250LG03-Lithium-Battery-User-Guide.pdf
C01C01Fault
Description

Battery overvoltage.

Recommended fix

Restart the unit, if the error persists, contact the repair center.

Source:LUX-X-48050LG01-low-voltage-battery-user-guide.pdf · page 17
C01Battery overvoltage.Critical
Description

Total battery pack voltage has exceeded the upper protection threshold.

Recommended fix

Restart the unit; if the error persists, contact the repair center.

Source:LUX-X-48100LG01-Litium-Battery-User-Guide.pdf · page 17
C01Battery overvoltage.Critical
Description

Total battery pack voltage has exceeded the upper protection threshold.

Recommended fix

Restart the unit, if the error persists, contact the repair center.

Source:358-S010024-03LUX-X-48100LG01-User-manual_compressed.pdf · page 23
C01Battery overvoltage.Fault
Cause

Battery pack voltage exceeded the upper protection threshold.

Recommended fix

Restart the unit. if the error persists, contact the repair center.

Source:LUX-Y-4828048300LG01-Lithium-Battery-User-Guide.pdf · page 8

Compiled from official FelicityESS user manuals. Always consult your device manual and a qualified technician before performing repairs.