What it means
Over-discharge - cannot be re-activated — Special Attention bullet on page 1 (section 1.4): 'Due to the built-in protection board of the lithium battery pack is with over-discharge protection function, it is strongly recommended to stop using the load when the battery pack is over-discharged. The battery pack cannot be repeatedly activated for discharge. Or the battery may be failed to be activated by the AC or PV activation cable (it requires a special charging activation method), so cannot be charged.' This is a documented advisory rather than a numbered C-code, but it describes a distinct unrecoverable condition reachable through C02 / C04.
Cause: Repeated activation attempts on a deeply over-discharged pack, exhausting the BMS's normal wake-up path so that even AC or PV activation no longer works.
How to fix it
- Stop using the load as soon as low power is indicated and recharge the battery from mains or solar as soon as possible.
- If the pack cannot be activated by the AC or PV activation cable, contact the supplier - a special charging activation method is required.
Source: 358-010291-07.pdf, p.1