ADVISORY: Over-discharge / activation failureCritical

Felicity battery error ADVISORY: Over-discharge / activation failure

Over-discharge - cannot be re-activated

Criticalthe battery shuts down and latches a protection fault. Don't keep restarting it — the cause needs checking first.

LPBF48100-M

BatteryCritical

What it means

Over-discharge - cannot be re-activatedSpecial Attention bullet on page 1 (section 1.4): 'Due to the built-in protection board of the lithium battery pack is with over-discharge protection function, it is strongly recommended to stop using the load when the battery pack is over-discharged. The battery pack cannot be repeatedly activated for discharge. Or the battery may be failed to be activated by the AC or PV activation cable (it requires a special charging activation method), so cannot be charged.' This is a documented advisory rather than a numbered C-code, but it describes a distinct unrecoverable condition reachable through C02 / C04.

Cause: Repeated activation attempts on a deeply over-discharged pack, exhausting the BMS's normal wake-up path so that even AC or PV activation no longer works.

How to fix it

  1. Stop using the load as soon as low power is indicated and recharge the battery from mains or solar as soon as possible.
  2. If the pack cannot be activated by the AC or PV activation cable, contact the supplier - a special charging activation method is required.

Source: 358-010291-07.pdf, p.1

Frequently asked questions

What does error ADVISORY: Over-discharge / activation failure mean on a Felicity battery?
ADVISORY: Over-discharge / activation failure means: Over-discharge - cannot be re-activated. Repeated activation attempts on a deeply over-discharged pack, exhausting the BMS's normal wake-up path so that even AC or PV activation no longer works.
Is error ADVISORY: Over-discharge / activation failure a fault or a warning?
ADVISORY: Over-discharge / activation failure is a fault code: the battery enters protection and stops normal operation until it is cleared.
How do I clear or fix error ADVISORY: Over-discharge / activation failure?
Stop using the load as soon as low power is indicated and recharge the battery from mains or solar as soon as possible. if the pack cannot be activated by the AC or PV activation cable, contact the supplier - a special charging activation method is required.

Related error codes

Prefer the full written guide? Read the complete Felicity inverter error-code guide

Compiled from official Felicity user manuals. Always consult your device manual and a qualified technician before performing repairs.