FLA48500

Battery14 codes
14 Fault
C01Battery overvoltage.Fault
Description

Battery overvoltage protection triggered (pack-level voltage exceeded threshold).

Cause

Battery pack voltage above operating limit (operating range 44.8-57.6V; max charging voltage 57.6V).

Recommended fix

Restart the unit. if the error persists, contact the repair center.

Source:felicitysolar FLA48500 LiFePO4 Battery System for Households User Guide.pdf
C02Battery undervoltage.Fault
Description

Battery undervoltage protection triggered (pack-level voltage below threshold).

Cause

Battery pack voltage below cut-off (cut-off voltage 48V); over-discharge condition.

Recommended fix

Restart the unit. if the error persists, contact the repair center.

Source:felicitysolar FLA48500 LiFePO4 Battery System for Households User Guide.pdf
C03Cell overvoltage.Fault
Description

Individual cell overvoltage protection triggered.

Cause

One or more cells exceeded the per-cell upper voltage limit.

Recommended fix

Restart the unit. if the error persists, contact the repair center.

Source:felicitysolar FLA48500 LiFePO4 Battery System for Households User Guide.pdf
C04Cell undervoltage.Fault
Description

Individual cell undervoltage protection triggered.

Cause

One or more cells dropped below the per-cell lower voltage limit.

Recommended fix

Restart the unit. if the error persists, contact the repair center.

Source:felicitysolar FLA48500 LiFePO4 Battery System for Households User Guide.pdf
C05Charge overcurrent.Fault
Description

Charging current exceeded the allowable limit.

Cause

Charge current above recommended (≤200A continuous, 300A 15s peak).

Recommended fix

Restart the unit. if the error persists, contact the repair center.

Source:felicitysolar FLA48500 LiFePO4 Battery System for Households User Guide.pdf
C06Discharge overcurrent.Fault
Description

Discharging current exceeded the allowable limit.

Cause

Discharge current above recommended (≤200A continuous, 300A 15s peak).

Recommended fix

Restart the unit. if the error persists, contact the repair center.

Source:felicitysolar FLA48500 LiFePO4 Battery System for Households User Guide.pdf
C07MOS overtemperature.Fault
Description

MOSFET (BMS power switch) over-temperature protection.

Cause

1. The inner temperature is over the limitation. 2. Check whether the ambient temperature is too high.

Recommended fix

Reduce ambient temperature / improve ventilation; restart the unit. if the error persists, return to repair center.

Source:felicitysolar FLA48500 LiFePO4 Battery System for Households User Guide.pdf
C08MOS undertemperature.Fault
Description

MOSFET (BMS power switch) under-temperature protection.

Cause

1. The internal temperature is lower than the limit range. 2. Check whether the ambient temperature is too low.

Recommended fix

Raise ambient temperature into operating range (charging 0-55°C; discharging -20-55°C); restart the unit. if the error persists, return to repair center.

Source:felicitysolar FLA48500 LiFePO4 Battery System for Households User Guide.pdf
C09Cell overtemperature.Fault
Description

Battery cell over-temperature protection triggered.

Cause

Cell temperature exceeded upper limit (charging temperature range 0-55°C, discharging -20-55°C).

Recommended fix

Restart the unit. if the error persists, contact the repair center.

Source:felicitysolar FLA48500 LiFePO4 Battery System for Households User Guide.pdf
C10Cell undertemperature.Fault
Description

Battery cell under-temperature protection triggered.

Cause

Cell temperature below lower limit.

Recommended fix

Restart the unit. if the error persists, contact the repair center.

Source:felicitysolar FLA48500 LiFePO4 Battery System for Households User Guide.pdf
C11Abnormal current sampling.Fault
Description

Internal current measurement / sampling circuit abnormal.

Cause

Hardware/sensor abnormality in current sampling path.

Recommended fix

Restart the unit. if the error persists, contact the repair center.

Source:felicitysolar FLA48500 LiFePO4 Battery System for Households User Guide.pdf
C12Abnormal output impedance.Fault
Description

Output impedance abnormal.

Cause

Abnormal impedance detected on output (possible bad connection, contactor or wiring issue).

Recommended fix

Restart the unit. if the error persists, contact the repair center.

Source:felicitysolar FLA48500 LiFePO4 Battery System for Households User Guide.pdf
C13Parallel failed.Fault
Description

Parallel connection / parallel-mode start-up failed.

Cause

Parallel condition not satisfied (e.g. pack-to-pack voltage difference ≥3V, or wiring issue between paralleled units).

Recommended fix

1. Please check if single unit is installed in parallel system. 2. if this error happens during parallel installation, please check wires connection. if they are connected correctly, please finish parallel installation first, and then Restart the unit. 3. if the problem remains, please contact your installer.

Source:felicitysolar FLA48500 LiFePO4 Battery System for Households User Guide.pdf
C14Output loss.Fault
Description

Output loss / no output detected.

Cause

Breaker open, blown fuse, or output path interrupted.

Recommended fix

1. Please check whether the circuit breaker is closed; 2. Please check whether the fuse is normal; 3. Restart the unit. if the error persists, contact the repair center.

Source:felicitysolar FLA48500 LiFePO4 Battery System for Households User Guide.pdf

Compiled from official FelicityESS user manuals. Always consult your device manual and a qualified technician before performing repairs.