Felicity FLA48500 Error Codes: Causes & Fixes (14 codes)

This is the complete fault table for the Felicity FLA48500 Battery — all 14 codes from the official manual on one page. On this Felicity device, a fault code means the unit has entered protection and stopped normal operation; a warning leaves it running. The exact indication (LED pattern or display code) is listed per code below.

Last checked against the official manuals on July 10, 2026.

How to read the severity labels

  • Fault(14)operation stops until cleared

Fault codes (14)operation stops until cleared

C01Fault

Battery overvoltage.

Fault

Battery overvoltage protection triggered (pack-level voltage exceeded threshold).

CauseBattery pack voltage above operating limit (operating range 44.8-57.6V; max charging voltage 57.6V).

Recommended fixRestart the unit. if the error persists, contact the repair center.

Source:felicitysolar FLA48500 LiFePO4 Battery System for Households User Guide.pdf

C02Fault

Battery undervoltage.

Fault

Battery undervoltage protection triggered (pack-level voltage below threshold).

CauseBattery pack voltage below cut-off (cut-off voltage 48V); over-discharge condition.

Recommended fixRestart the unit. if the error persists, contact the repair center.

Source:felicitysolar FLA48500 LiFePO4 Battery System for Households User Guide.pdf

C03Fault

Cell overvoltage.

Fault

Individual cell overvoltage protection triggered.

CauseOne or more cells exceeded the per-cell upper voltage limit.

Recommended fixRestart the unit. if the error persists, contact the repair center.

Source:felicitysolar FLA48500 LiFePO4 Battery System for Households User Guide.pdf

C04Fault

Cell undervoltage.

Fault

Individual cell undervoltage protection triggered.

CauseOne or more cells dropped below the per-cell lower voltage limit.

Recommended fixRestart the unit. if the error persists, contact the repair center.

Source:felicitysolar FLA48500 LiFePO4 Battery System for Households User Guide.pdf

C05Fault

Charge overcurrent.

Fault

Charging current exceeded the allowable limit.

CauseCharge current above recommended (≤200A continuous, 300A 15s peak).

Recommended fixRestart the unit. if the error persists, contact the repair center.

Source:felicitysolar FLA48500 LiFePO4 Battery System for Households User Guide.pdf

C06Fault

Discharge overcurrent.

Fault

Discharging current exceeded the allowable limit.

CauseDischarge current above recommended (≤200A continuous, 300A 15s peak).

Recommended fixRestart the unit. if the error persists, contact the repair center.

Source:felicitysolar FLA48500 LiFePO4 Battery System for Households User Guide.pdf

C07Fault

MOS overtemperature.

Fault

MOSFET (BMS power switch) over-temperature protection.

Cause1. The inner temperature is over the limitation. 2. Check whether the ambient temperature is too high.

Recommended fixReduce ambient temperature / improve ventilation; restart the unit. if the error persists, return to repair center.

Source:felicitysolar FLA48500 LiFePO4 Battery System for Households User Guide.pdf

C08Fault

MOS undertemperature.

Fault

MOSFET (BMS power switch) under-temperature protection.

Cause1. The internal temperature is lower than the limit range. 2. Check whether the ambient temperature is too low.

Recommended fixRaise ambient temperature into operating range (charging 0-55°C; discharging -20-55°C); restart the unit. if the error persists, return to repair center.

Source:felicitysolar FLA48500 LiFePO4 Battery System for Households User Guide.pdf

C09Fault

Cell overtemperature.

Fault

Battery cell over-temperature protection triggered.

CauseCell temperature exceeded upper limit (charging temperature range 0-55°C, discharging -20-55°C).

Recommended fixRestart the unit. if the error persists, contact the repair center.

Source:felicitysolar FLA48500 LiFePO4 Battery System for Households User Guide.pdf

C10Fault

Cell undertemperature.

Fault

Battery cell under-temperature protection triggered.

CauseCell temperature below lower limit.

Recommended fixRestart the unit. if the error persists, contact the repair center.

Source:felicitysolar FLA48500 LiFePO4 Battery System for Households User Guide.pdf

C11Fault

Abnormal current sampling.

Fault

Internal current measurement / sampling circuit abnormal.

CauseHardware/sensor abnormality in current sampling path.

Recommended fixRestart the unit. if the error persists, contact the repair center.

Source:felicitysolar FLA48500 LiFePO4 Battery System for Households User Guide.pdf

C12Fault

Abnormal output impedance.

Fault

Output impedance abnormal.

CauseAbnormal impedance detected on output (possible bad connection, contactor or wiring issue).

Recommended fixRestart the unit. if the error persists, contact the repair center.

Source:felicitysolar FLA48500 LiFePO4 Battery System for Households User Guide.pdf

C13Fault

Parallel failed.

Fault

Parallel connection / parallel-mode start-up failed.

CauseParallel condition not satisfied (e.g. pack-to-pack voltage difference ≥3V, or wiring issue between paralleled units).

Recommended fix1. Please check if single unit is installed in parallel system. 2. if this error happens during parallel installation, please check wires connection. if they are connected correctly, please finish parallel installation first, and then Restart the unit. 3. if the problem remains, please contact your installer.

Source:felicitysolar FLA48500 LiFePO4 Battery System for Households User Guide.pdf

C14Fault

Output loss.

Fault

Output loss / no output detected.

CauseBreaker open, blown fuse, or output path interrupted.

Recommended fix1. Please check whether the circuit breaker is closed; 2. Please check whether the fuse is normal; 3. Restart the unit. if the error persists, contact the repair center.

Source:felicitysolar FLA48500 LiFePO4 Battery System for Households User Guide.pdf

Still seeing a code on your FLA48500?

Send us the code on your screen and a Felicity technician will reply with the exact steps for your unit. Support is free for life — a first diagnosis never needs a callout.

Keep troubleshooting

Related devices

Common questions about FLA48500 error codes

What is the difference between a fault and a warning on the FLA48500?
A fault puts the unit into protection and stops normal operation — this page lists 14 of them for the FLA48500. The FLA48500 manual defines no separate warning table — every listed code stops operation. Resolve the cause of a fault before restarting; warnings can usually be cleared while the unit runs.
Does this page apply to other Felicity models?
No — this table was transcribed specifically from the FLA48500 manual. Other Felicity devices have their own pages; start from the error-code hub to find the one matching the model number on your unit's label.
Where do these codes come from?
Every entry was transcribed from felicitysolar FLA48500 LiFePO4 Battery System for Households User Guide.pdf — Felicity's official documentation. Each row cites its source manual (and page where printed), so you can verify the wording before acting on it.

Compiled from official Felicity user manuals. Always consult your device manual and a qualified technician before performing repairs.