C01
Battery overvoltage.
C01Battery overvoltage.Défaut
Battery overvoltage fault. LED pattern: LED1 FLASH, LED2 OFF, LED3 OFF, LED4 OFF (with FAULT mode: GREEN OFF, RED ON).
Restart the unit. if the error persists, contact the repair center.
Felicitysolar FLA12100 12.5Kwh Battery Energy Storage System User Manual.pdf · page 1C01Battery overvoltage.Défaut— high
Total battery pack voltage exceeded the upper limit.
Restart the unit. if the error persists, contact the repair center.
Felicitysolar FLA48200 48V 200Ah 10kWh Lithium Phosphate Battery User Manual.pdf · page 12C01Battery overvoltage.Critique
BMS reports total battery pack voltage above the upper protection threshold.
Restart the unit. if the error persists, contact the repair center.
6peluqppy_66a93554057c8.pdf · page 12C01C01Défaut
Battery overvoltage.
Restart the unit. if the error persists, contact the repair center.
FLA48250-EU_Manual.pdf · page 8C01Battery overvoltage.Défaut
Battery overvoltage protection triggered (pack-level voltage exceeded threshold).
Battery pack voltage above operating limit (operating range 44.8-57.6V; max charging voltage 57.6V).
Restart the unit. if the error persists, contact the repair center.
felicitysolar FLA48500 LiFePO4 Battery System for Households User Guide.pdfC01Batterie-Überspannung.Défaut
Battery overvoltage. Total pack voltage exceeded the rated upper protection threshold during charging.
Total battery pack voltage above rated value (Gesamtspannung des Akkupacks über dem Nennwert). Charging continued past the over-voltage protection point.
Restart the unit. if the error persists, return to repair centre. (Gerät neu starten; bei Wiederauftreten zur Reparatur einsenden.).
Benutzerhandbuch - Felicity FLS48100SG2.pdfC01Battery overvoltage.Défaut
Battery overvoltage protection triggered (pack-level voltage exceeded threshold).
Battery pack voltage above operating limit (operating range 44.8-57.6V; max charging voltage 57.6V).
Restart the unit. if the error persists, contact the repair center.
HE-GF-FLA-48500 Manual_20250327_EN.pdfC01Battery overvoltage.Défaut
Pack-level over-voltage fault displayed on the LCD BMS fault code / flag screen (section 4.3-4.4); fault icon is constant.
Pack voltage exceeded the BMS over-voltage threshold during charging - typically because the charger's Max. Charging Voltage is set above the recommended 57.6 V (section 2.4 Recommended Settings).
Restart the unit; if the error persists, contact the repair center. Verify the charger / inverter Max. Charging Voltage and Floating Charging Voltage are set to 57.6 V and pack voltage stays within the 48-57.6 V operating range.
358-010291-07.pdf · page 8C01Battery overvoltage.Défaut
Battery pack overall voltage above protection threshold (BMS protection).
Total battery voltage has exceeded the BMS upper voltage limit.
Restart the unit; if the error persists, contact the repair center.
Manual-LPBF48200-H.pdf · page 10C01C01Défaut
Restart the unit, if the error persists, contact the repair center.
Felicitysolar LPBF48350 17.5kWh 48V Solar Battery Pack with BMS User Guide.pdfC01Battery overvoltage.Défaut
Battery pack voltage exceeded the upper protection threshold.
Restart the unit. if the error persists, contact the repair center.
LUX-E-48100LG03-Lithium-Battery-User-Guide.pdf · page 12C01C01Défaut
Restart the unit. if the error persists, contact the repair center.
LUX-E-48200LG03-Lithium-Battery-User-Guide.pdf · page 12C01C01Défaut
Restart the unit. if the error persists, contact the repair center.
LUX-E-48230.250LG03-Lithium-Battery-User-Guide.pdfC01C01Défaut
Battery overvoltage.
Restart the unit, if the error persists, contact the repair center.
LUX-X-48050LG01-low-voltage-battery-user-guide.pdf · page 17C01Battery overvoltage.Critique
Total battery pack voltage has exceeded the upper protection threshold.
Restart the unit; if the error persists, contact the repair center.
LUX-X-48100LG01-Litium-Battery-User-Guide.pdf · page 17C01Battery overvoltage.Critique
Total battery pack voltage has exceeded the upper protection threshold.
Restart the unit, if the error persists, contact the repair center.
358-S010024-03LUX-X-48100LG01-User-manual_compressed.pdf · page 23C01Battery overvoltage.Défaut
Battery pack voltage exceeded the upper protection threshold.
Restart the unit. if the error persists, contact the repair center.
LUX-Y-4828048300LG01-Lithium-Battery-User-Guide.pdf · page 8Compilé à partir des manuels utilisateur officiels FelicityESS. Consultez toujours le manuel de votre appareil et un technicien qualifié avant toute réparation.