The Felicity LUX-E-48100LG03 is a Battery unit. The 14 error codes listed below are the complete fault catalog for this device, compiled from the official Felicity user manual.
The Felicity LUX-E-48100LG03 is a Battery unit. The 14 error codes listed below are the complete fault catalog for this device, compiled from the official Felicity user manual.
Each row below shows an error code, its severity, and a brief description. Click any row to expand the full cause and the recommended fix. The severity dot tells you whether the unit will keep operating (warning), derate (fault), or trip offline (critical). For codes that require an authorized service partner, the recommended-fix block says so explicitly.
Battery pack voltage exceeded the upper protection threshold.
Restart the unit. if the error persists, contact the repair center.
LUX-E-48100LG03-Lithium-Battery-User-Guide.pdf · page 12Battery pack voltage fell below the lower protection threshold.
Restart the unit. if the error persists, contact the repair center.
LUX-E-48100LG03-Lithium-Battery-User-Guide.pdf · page 12An individual cell voltage exceeded the upper protection threshold.
Restart the unit. if the error persists, contact the repair center.
LUX-E-48100LG03-Lithium-Battery-User-Guide.pdf · page 12An individual cell voltage fell below the lower protection threshold.
Restart the unit. if the error persists, contact the repair center.
LUX-E-48100LG03-Lithium-Battery-User-Guide.pdf · page 12Charging current exceeded the protection threshold.
Restart the unit. if the error persists, contact the repair center.
LUX-E-48100LG03-Lithium-Battery-User-Guide.pdf · page 12Discharging current exceeded the protection threshold.
Restart the unit. if the error persists, contact the repair center.
LUX-E-48100LG03-Lithium-Battery-User-Guide.pdf · page 12The inner temperature is over the limitation. Check whether the ambient temperature is too high.
Check whether the ambient temperature is too high; allow the unit to cool. if the error persists, return to repair center.
LUX-E-48100LG03-Lithium-Battery-User-Guide.pdf · page 12The internal temperature is lower than the limit range. Check whether the ambient temperature is too low.
Check whether the ambient temperature is too low; warm the environment. if the error persists, return to repair center.
LUX-E-48100LG03-Lithium-Battery-User-Guide.pdf · page 12An individual cell temperature exceeded the upper protection threshold.
Restart the unit. if the error persists, contact the repair center.
LUX-E-48100LG03-Lithium-Battery-User-Guide.pdf · page 13An individual cell temperature fell below the lower protection threshold.
Restart the unit. if the error persists, contact the repair center.
LUX-E-48100LG03-Lithium-Battery-User-Guide.pdf · page 13BMS detected an abnormal reading from the current-sampling circuit.
Restart the unit. if the error persists, contact the repair center.
LUX-E-48100LG03-Lithium-Battery-User-Guide.pdf · page 13BMS detected abnormal output impedance (e.g. loose/poor connection at output terminals).
Restart the unit. if the error persists, contact the repair center.
LUX-E-48100LG03-Lithium-Battery-User-Guide.pdf · page 13Parallel-connection condition not satisfied. Possible causes: (1) a single unit is configured as part of a parallel system; (2) wires are mis-connected during parallel installation.
1. Check if a single unit is wrongly installed to a parallel system. 2. if the error happens during parallel installation, check wires connection. if they are connected correctly, finish parallel installation first, then restart the unit. 3. if the problem remains, please contact your installer.
LUX-E-48100LG03-Lithium-Battery-User-Guide.pdf · page 13No output from the battery pack. Possible causes: circuit breaker open, or fuse blown.
1. Please check whether the circuit breaker is closed. 2. Please check whether the fuse is normal. 3. Restart the unit. if the error persists, contact the repair center.
LUX-E-48100LG03-Lithium-Battery-User-Guide.pdf · page 13Write down the exact code shown on the display, what the unit was doing when it appeared (charging, discharging, idle, grid-tied), and any LEDs or audible alarms. The same code can have different fixes depending on context.
Find the code in the list below and read the cause + recommended fix. Most warning-level codes can be cleared by following the listed action — usually reducing load, checking wiring, or restarting the unit.
Each code shows the source manual filename and page number. Open that exact page in the official manual to verify model-specific notes (firmware version, parallel-config notes, regional variants) before acting.
If a fix requires opening the enclosure or accessing terminals, disconnect AC input, DC PV, and battery in that order. Wait at least 60 seconds for capacitors to discharge before touching any conductors.
Critical codes (short-circuit, IGBT failure, BMS hardware error) should not be cleared by end users. Note the code, model number, and source manual page, then contact an authorized service partner.