16.3 A maximum output current
the T-REX-3KLP1G01 pushes past its 13 A rated output at 230 V single-phase, L+N+PE

A 3 kW single-phase hybrid inverter rated for 16.3 A maximum output, taking up to 3.9 kW of recommended PV across two MPPT trackers and one 40-60 V battery input.
In stock
The Felicity Solar T-REX-3KLP1G01 is a 3 kW single-phase hybrid inverter that holds a 16.3 A maximum output current at 230 V, reaches 97.5% peak and 96.7% European efficiency, and accepts up to 3.9 kW of recommended PV power across two MPPT trackers working from 100-500 V. On the array side it takes 40 A of PV input current and 550 V maximum PV voltage, starts up at 130 V, is rated at 360 V, and tracks at 99.9% efficiency. One battery input covers 40-60 V for Lead-Acid or Li-Ion packs, charging and discharging at up to 100 A with a charge algorithm that self-adapts to the BMS over RS485 or CAN. Backup output is rated 3 kW and 30 A with a 20 ms transfer time, under 3% total harmonic distortion and a power factor above 0.99. The wall-mounted enclosure is IP65 and naturally cooled, weighs 32.4 kg net, runs from -25 to 60 °C with derating above 45 °C, parallels to 6 units and is built to IEC 62109-1 and IEC 62109-2. We are an authorised Felicity Solar distributor and supply the T-REX-3KLP1G01 from our own stock. Warranty: 2 Years.
Specifications last updated 23 March 2026
| AC Output Voltage | 230 V |
|---|---|
| AC Rated Output Current | 13 A |
| AC Wiring Mode | L+N+PE |
| Backup Max Output Current | 30 A |
| Backup Rated Output Power | 3 kW |
| Battery Inputs | 1 |
| Battery Type | Lead-Acid, Li-Ion |
| Battery Voltage Range | 40-60 V |
| Charge Algorithm | Self-Adaption to BMS |
| European Efficiency | 96.7 % |
| Grid Frequency Range (50 Hz) | 45-55 Hz |
| Grid Frequency Range (60 Hz) | 55-65 Hz |
| Grid Regulation | CEI 0-21, G99, VDE 4105, EN 50549-1, NRS 097-2-1, C10/11, NTS & UNE217001 & UNE217002, PORTARIA N° 140 & 515 |
| Ground Fault Current Monitoring | Yes |
| Input Voltage Range | 184-264.5 V |
| MPPT Efficiency | 99.9 % |
| MPPT Full-Load Voltage Range | 140-500 V |
| MPPT Trackers | 2 |
| MPPT Voltage Range | 100-500 V |
| Max AC Charge Current | 100 A |
| Max AC Input Current | 40 A |
| Max AC Output Power | 3 kW |
| Max AC Pass-Through Current | 30 A |
| Max Charge/Discharge Power | 3 kW |
| Max Charging Current | 100 A |
| Max Discharging Current | 100 A |
| Max Efficiency | 97.5 % |
| Max Output Current | 16.3 A |
| Max PV Input Current | 40 A |
| Max PV Voltage | 550 V |
| Max Recommended PV Power | 3.9 kW |
| Max Short-Circuit Current | 18+18 A |
| Nominal AC Input Voltage | 230 V |
| Nominal Input Frequency | 50/60 Hz |
| Output Frequency | 50/60 Hz |
| Output Short-Circuit Protection | Yes |
| Overload Protection | Yes |
| PV Working Voltage Range | 90-550 V |
| Phase | Single Phase |
| Power Factor | >0.99 |
| Power Factor Adjustment Range | 0.8 leading to 0.8 lagging |
| Protection | Output Over Current Protection, Output Over Power Protection, Output Short-Circuit Protection, Anti-islanding Protection, GFCI Protection, Insulation Resistor Detection |
| Rated Apparent Output Power | 3 kVA |
| Rated Output Power | 3 kW |
| Rated PV Input Voltage | 360 V |
| Start-Up Voltage | 130 V |
| Strings per MPPT | 1 |
| Surge Rating | 2*rated (10s) |
| Total Harmonic Distortion | <3 % |
| Transfer Time | 20 ms |
| BMS Communication | RS485, CAN |
|---|---|
| Communication Interface | RS232, RS485 |
| Display | LCD, LED |
| Gross Weight | 39.1 kg |
| Installation Style | Wall-Mounted |
| Monitoring Module | WiFi/GPRS |
| Net Weight | 32.4 kg |
| Package Dimensions | 632 x 570 x 315 mm |
| Parallel Capability | 6 |
| Safety Standard | IEC 62109-1, IEC 62109-2 |
| Topology | Isolated (transformer-based) |
| Cooling | Nature |
|---|---|
| IP Rating | IP65 |
| Operating Altitude | 2000 m |
| Operating Temperature Range | -25 to 60 (>45 derating) °C |
| Relative Humidity | 0-100 % |
Looking up an error code on this FelicityESS T-REX-3KLP1G01? Browse the full list of codes for this device, with the cause and recommended fix for each.
View error codes for this device →



Twenty-five Felicity inverters are IP21 and every SCCM charge controller says indoor wall-mount. IP20, IP21 and IP31 are indoor ratings, and the first digit - the dust one - is the half nobody reads. Here is which listing carries which.
Read: Can I Install a Solar Inverter Outside? What IP21, IP31 and IP65 Really Mean →On IVPS/IVPM models, continuous beep + solid red = fault, output cut; intermittent beeping + flashing red = warning. The number on the LCD is the fix.
Read: Felicity Inverter Beeping? What the Beeps & Red Light Mean →An off-grid house is sized by surge, battery energy and charge current - and the surge row is the one that starts your fridge and your pump. Here are the published figures across the Felicity inverters and batteries, with the arithmetic to use them.
Read: How to Run a Whole House on Solar in Khartoum →3.9 kW is the maximum recommended PV power. Two MPPT trackers run from 100-500 V (140-500 V at full load) and 90-550 V working range, accept 40 A of PV input current with 18+18 A of short-circuit current, and tolerate 550 V maximum PV voltage. Each tracker takes one string, start-up begins at 130 V and rated PV input voltage is 360 V.
16.3 A is the maximum output current at 230 V single-phase, above the 13 A rated output current, for 3 kW of rated and maximum AC output power. Backup output is 3 kW at 30 A with a 20 ms transfer time and a surge rating of 2*rated (10s), at under 3% total harmonic distortion and a power factor above 0.99.
100 A is both the maximum charge and the maximum discharge current, on one battery input covering 40-60 V for Lead-Acid or Li-Ion packs, with 3 kW of maximum charge/discharge power. The charge algorithm self-adapts to the BMS over RS485 or CAN, and AC charging also reaches 100 A from a 40 A maximum AC input current.
530 x 493 x 228 mm is the unit's own size, at 32.4 kg net; packed it is 632 x 570 x 315 mm and 39.1 kg gross. It is wall-mounted with an IP65 enclosure and natural cooling, works from -25 to 60 °C with derating above 45 °C, 0-100% humidity and up to 2000 m altitude, and is monitored over WiFi/GPRS with an LCD and LED display.