Felicity Solar Hybrid Inverters 3-6 kW T-REX-3K6LP1G01 / T-REX-3KLP1G01 / T-REX-4K6LP1G01 / T-REX-4KLP1G01 / T-REX-5KLP1G01 / T-REX-6KLP1G01
Single-phase 3.6 kW hybrid inverter delivering 19.5 A maximum output current, 96.7% European efficiency and a 20 ms transfer to 3.6 kW of backup power.
Models and prices
- T-REX-3K6LP1G01AED 1,650incl. VAT
- T-REX-3KLP1G01AED 1,650incl. VAT
- T-REX-4K6LP1G01AED 1,650incl. VAT
- T-REX-4KLP1G01AED 1,650incl. VAT
- T-REX-5KLP1G01AED 1,650incl. VAT
- T-REX-6KLP1G01AED 1,650incl. VAT
Technical Specifications
| Parameter | T-REX-3K6LP1G01 | T-REX-3KLP1G01 | T-REX-4K6LP1G01 | T-REX-4KLP1G01 | T-REX-5KLP1G01 | T-REX-6KLP1G01 |
|---|---|---|---|---|---|---|
| Performance & Electrical | ||||||
| AC Output Voltage | 230 V | |||||
| AC Rated Output Current | 15.6 A | 13 A | 20 A | 17.4 A | 21.7 A | 26 A |
| AC Wiring Mode | L+N+PE | |||||
| Backup Max Output Current | 30 A | |||||
| Backup Rated Output Power | 3.6 kW | 3 kW | 4.6 kW | 4 kW | 5 kW | 6 kW |
| Battery Inputs | 1 | |||||
| Battery Type | Lead-Acid, Li-Ion | |||||
| Battery Voltage Range | 40-60 V | |||||
| Charge Algorithm | Self-Adaption to BMS | |||||
| European Efficiency | 96.7% | 96.7% | 97% | 96.8% | 97% | 97% |
| Grid Frequency Range (50 Hz) | 45-55 Hz | |||||
| Grid Frequency Range (60 Hz) | 55-65 Hz | |||||
| Grid Regulation | CEI 0-21, G99, VDE 4105, EN 50549-1, NRS 097-2-1, C10/11, NTS & UNE217001 & UNE217002, PORTARIA N° 140 & 515 | |||||
| Ground Fault Current Monitoring | Yes | |||||
| Input Voltage Range | 184-264.5 V | |||||
| MPPT Efficiency | 99.9% | |||||
| MPPT Full-Load Voltage Range | 160-500 V | 140-500 V | 200-500 V | 175-500 V | 220-500 V | 260-500 V |
| MPPT Trackers | 2 | |||||
| MPPT Voltage Range | 100-500 V | |||||
| Max AC Charge Current | 100 A | 100 A | 100 A | 100 A | 100 A | 120 A |
| Max AC Input Current | 40 A | |||||
| Max AC Output Power | 3.6 kW | 3 kW | 4.6 kW | 4 kW | 5 kW | 6 kW |
| Max AC Pass-Through Current | 30 A | 30 A | 30 A | 30 A | 40 A | 40 A |
| Max Charge/Discharge Power | 3.6 kW | 3 kW | 4.6 kW | 4 kW | 5 kW | 6 kW |
| Max Charging Current | 100 A | 100 A | 100 A | 100 A | 100 A | 120 A |
| Max Discharging Current | 100 A | 100 A | 100 A | 100 A | 100 A | 120 A |
| Max Efficiency | 97.5% | 97.5% | 97.6% | 97.5% | 97.6% | 97.6% |
| Max Output Current | 19.5 A | 16.3 A | 25 A | 21.7 A | 25 A | 30 A |
| Max PV Input Current | 15+15 A | 40 A | 15+15 A | 15+15 A | 15+15 A | 15+15 A |
| Max PV Voltage | 550 V | |||||
| Max Recommended PV Power | 4.7 kW | 3.9 kW | 6 kW | 5.2 kW | 6.5 kW | 7.8 kW |
| Max Short-Circuit Current | 18+18 A | |||||
| Nominal AC Input Voltage | 230 V | |||||
| Nominal Input Frequency | 50/60 Hz | |||||
| Output Frequency | 50/60 Hz | |||||
| Output Short-Circuit Protection | Yes | |||||
| Overload Protection | Yes | |||||
| PV Working Voltage Range | 90-550 V | |||||
| Phase | Single Phase | |||||
| Power Factor | >0.99 | |||||
| Power Factor Adjustment Range | 0.8 leading to 0.8 lagging | |||||
| Protection | Output Over Current Protection, Output Over Power Protection, Output Short-Circuit Protection, Anti-islanding Protection, GFCI Protection, Insulation Resistor Detection | |||||
| Rated Apparent Output Power | 3.6 kVA | 3 kVA | 4.6 kVA | 4 kVA | 5 kVA | 6 kVA |
| Rated Output Power | 3.6 kW | 3 kW | 4.6 kW | 4 kW | 5 kW | 6 kW |
| Rated PV Input Voltage | 360 V | |||||
| Start-Up Voltage | 130 V | |||||
| Strings per MPPT | 1 | |||||
| Surge Rating | 2*rated (10s) | |||||
| Total Harmonic Distortion | <3% | |||||
| Transfer Time | 20 ms | |||||
| Build & Interfaces | ||||||
| BMS Communication | RS485, CAN | |||||
| Communication Interface | RS232, RS485 | |||||
| Display | LCD, LED | |||||
| Gross Weight | 39.1 kg | |||||
| Installation Style | Wall-Mounted | |||||
| Monitoring Module | WiFi/GPRS | |||||
| Net Weight | 32.4 kg | |||||
| Package Dimensions | 632 x 570 x 315 mm | |||||
| Parallel Capability | 6 | |||||
| Safety Standard | IEC 62109-1, IEC 62109-2 | |||||
| Topology | Isolated (transformer-based) | |||||
| Operating Environment | ||||||
| Cooling | Nature | Nature | Nature | Nature | Nature | Intelligent Air Cooling |
| IP Rating | IP65 | |||||
| Operating Altitude | 2000 m | |||||
| Operating Temperature Range | -25 to 60 (>45 derating) °C | |||||
| Relative Humidity | 0-100% | |||||
Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.
Availability & grid compliance in the UAE
| Market | UAE |
|---|---|
| Grid authority / regulator | DEWA, ADDC, SEWA |
| Quotation currency | AED |
| Support hours timezone | Asia/Dubai |
| Main cities | Dubai, Abu Dhabi, Sharjah, Ajman, Ras Al Khaimah |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in the UAE that rests with the local authorities (DEWA, ADDC, SEWA). Confirm the grid code, import requirements and any local certification with them, or with us, before you order.
Key Features & Technical Highlights
- 3.6 kW rated output at 19.5 A maximum: Rated 3.6 kVA and 3.6 kW at 230 V single phase, with 15.6 A rated and 19.5 A maximum output current.
- 97.5% peak efficiency: 97.5% maximum efficiency, 96.7% European efficiency and 99.9% MPPT efficiency, with total harmonic distortion under 3%.
- Two MPPT trackers for 4.7 kW of panels: Two trackers spanning 100-500 V take 15+15 A and a recommended 4.7 kW of PV, under a 550 V maximum input and starting at 130 V.
- One 40-60 V battery input at 100 A: Charges and discharges lead-acid or Li-Ion packs at up to 100 A and 3.6 kW, self-adapting to the BMS over RS485 or CAN.
- 20 ms transfer to 3.6 kW of backup: Switches to backup in 20 ms and holds 3.6 kW with a 30 A maximum output current, with twice rated power on surge for 10 s.
- IP65 wall-mounted body of 32.4 kg: Naturally cooled IP65 enclosure of 530 x 493 x 228 mm weighing 32.4 kg net and 39.1 kg gross, running from -25 to 60 °C with derating above 45 °C.
- 16.3 A maximum output current: the T-REX-3KLP1G01 pushes past its 13 A rated output at 230 V single-phase, L+N+PE
- 3.9 kW of recommended PV power: two MPPT trackers span 100-500 V, take 40 A of PV input current and tolerate 550 V
- 97.5% peak and 96.7% European efficiency: MPPT tracking itself runs at 99.9%, with total harmonic distortion held under 3%
- 100 A charge and 100 A discharge: one 40-60 V battery input serves Lead-Acid or Li-Ion, self-adapting to the BMS over RS485 or CAN
- 20 ms transfer to a 3 kW backup output: backup supplies 30 A with anti-islanding, GFCI and insulation resistor detection
- IP65 from -25 to 60 °C: naturally cooled, wall-mounted, 32.4 kg net, and parallelable up to 6 units
Frequently Asked Questions
How much power does the T-REX-3K6LP1G01 deliver?
3.6 kW — the T-REX-3K6LP1G01 is rated 3.6 kVA and 3.6 kW at 230 V single phase on 50/60 Hz, giving 15.6 A rated and 19.5 A maximum output current. Peak efficiency is 97.5%, European efficiency 96.7%, and surge capacity is twice rated power for 10 s.
How many solar panels can the T-REX-3K6LP1G01 take?
4.7 kW is the maximum recommended PV power, split across two MPPT trackers carrying one string each. Each tracker accepts 15+15 A, or 18+18 A on short circuit, and works from 100-500 V — 160-500 V at full load — starting at 130 V and never exceeding a 550 V maximum PV voltage.
Which batteries work with the T-REX-3K6LP1G01?
40-60 V lead-acid or Li-Ion packs on its single battery input, charged and discharged at up to 100 A and 3.6 kW. The charge algorithm self-adapts to the pack's own BMS over RS485 or CAN, and the grid can charge the same bank at up to 100 A through a 40 A maximum AC input.
How quickly does the T-REX-3K6LP1G01 switch to backup?
20 ms. Backup output is rated 3.6 kW with a 30 A maximum output current at 230 V, the same 30 A that is the maximum AC pass-through. Anti-islanding, GFCI, insulation resistance detection and ground fault current monitoring are all built in.
How much solar can I connect to the T-REX-3KLP1G01?
3.9 kW is the maximum recommended PV power. Two MPPT trackers run from 100-500 V (140-500 V at full load) and 90-550 V working range, accept 40 A of PV input current with 18+18 A of short-circuit current, and tolerate 550 V maximum PV voltage. Each tracker takes one string, start-up begins at 130 V and rated PV input voltage is 360 V.
What output does the T-REX-3KLP1G01 deliver?
16.3 A is the maximum output current at 230 V single-phase, above the 13 A rated output current, for 3 kW of rated and maximum AC output power. Backup output is 3 kW at 30 A with a 20 ms transfer time and a surge rating of 2*rated (10s), at under 3% total harmonic distortion and a power factor above 0.99.
Which batteries does it charge, and how fast?
100 A is both the maximum charge and the maximum discharge current, on one battery input covering 40-60 V for Lead-Acid or Li-Ion packs, with 3 kW of maximum charge/discharge power. The charge algorithm self-adapts to the BMS over RS485 or CAN, and AC charging also reaches 100 A from a 40 A maximum AC input current.
How large is the T-REX-3KLP1G01 and where is it installed?
530 x 493 x 228 mm is the unit's own size, at 32.4 kg net; packed it is 632 x 570 x 315 mm and 39.1 kg gross. It is wall-mounted with an IP65 enclosure and natural cooling, works from -25 to 60 °C with derating above 45 °C, 0-100% humidity and up to 2000 m altitude, and is monitored over WiFi/GPRS with an LCD and LED display.
How much solar can the T-REX-4K6LP1G01 take?
Up to 6 kW of PV is the maximum recommended array for the T-REX-4K6LP1G01. Its two MPPT trackers accept 550 V and 15+15 A, work from 100-500 V and from 200-500 V at full load, and start tracking at 130 V.
How fast does the T-REX-4K6LP1G01 charge and discharge a battery?
100 A is the maximum charge and discharge current of the T-REX-4K6LP1G01, across a 40-60 V lead-acid or Li-Ion bank on its single battery input. Charge and discharge power is capped at 4.6 kW, and the charge algorithm self-adapts to the battery BMS over RS485 or CAN.