3.6 kW rated output at 19.5 A maximum
Rated 3.6 kVA and 3.6 kW at 230 V single phase, with 15.6 A rated and 19.5 A maximum output current.

Single-phase 3.6 kW hybrid inverter delivering 19.5 A maximum output current, 96.7% European efficiency and a 20 ms transfer to 3.6 kW of backup power.
In stock
The Felicity Solar T-REX-3K6LP1G01 is a single-phase hybrid solar inverter rated 3.6 kVA and 3.6 kW at 230 V, delivering 15.6 A rated and 19.5 A maximum output current at up to 97.5% efficiency, with two MPPT trackers that accept a recommended 4.7 kW of solar panels. European efficiency is 96.7% and MPPT efficiency 99.9%. Each tracker runs from 100-500 V, or 160-500 V at full load, takes 15+15 A and starts at 130 V, under a 550 V maximum PV input. A single 40-60 V battery input charges and discharges lead-acid or Li-Ion packs at up to 100 A and 3.6 kW, self-adapting to the pack's own BMS over RS485 or CAN. Grid failure transfers to backup in 20 ms, holding 3.6 kW and 30 A. The isolated, transformer-based unit is IP65, naturally cooled, wall-mounted at 530 x 493 x 228 mm and 32.4 kg, parallels to six units, and is certified to IEC 62109-1 and IEC 62109-2. We are an authorised Felicity Solar distributor and supply the T-REX-3K6LP1G01 from our own stock. Warranty: 2 Years.
Specifications last updated 23 March 2026
| AC Output Voltage | 230 V |
|---|---|
| AC Rated Output Current | 15.6 A |
| AC Wiring Mode | L+N+PE |
| Backup Max Output Current | 30 A |
| Backup Rated Output Power | 3.6 kW |
| Battery Inputs | 1 |
| Battery Type | Lead-Acid, Li-Ion |
| Battery Voltage Range | 40-60 V |
| Charge Algorithm | Self-Adaption to BMS |
| European Efficiency | 96.7 % |
| Grid Frequency Range (50 Hz) | 45-55 Hz |
| Grid Frequency Range (60 Hz) | 55-65 Hz |
| Grid Regulation | CEI 0-21, G99, VDE 4105, EN 50549-1, NRS 097-2-1, C10/11, NTS & UNE217001 & UNE217002, PORTARIA N° 140 & 515 |
| Ground Fault Current Monitoring | Yes |
| Input Voltage Range | 184-264.5 V |
| MPPT Efficiency | 99.9 % |
| MPPT Full-Load Voltage Range | 160-500 V |
| MPPT Trackers | 2 |
| MPPT Voltage Range | 100-500 V |
| Max AC Charge Current | 100 A |
| Max AC Input Current | 40 A |
| Max AC Output Power | 3.6 kW |
| Max AC Pass-Through Current | 30 A |
| Max Charge/Discharge Power | 3.6 kW |
| Max Charging Current | 100 A |
| Max Discharging Current | 100 A |
| Max Efficiency | 97.5 % |
| Max Output Current | 19.5 A |
| Max PV Input Current | 15+15 A |
| Max PV Voltage | 550 V |
| Max Recommended PV Power | 4.7 kW |
| Max Short-Circuit Current | 18+18 A |
| Nominal AC Input Voltage | 230 V |
| Nominal Input Frequency | 50/60 Hz |
| Output Frequency | 50/60 Hz |
| Output Short-Circuit Protection | Yes |
| Overload Protection | Yes |
| PV Working Voltage Range | 90-550 V |
| Phase | Single Phase |
| Power Factor | >0.99 |
| Power Factor Adjustment Range | 0.8 leading to 0.8 lagging |
| Protection | Output Over Current Protection, Output Over Power Protection, Output Short-Circuit Protection, Anti-islanding Protection, GFCI Protection, Insulation Resistor Detection |
| Rated Apparent Output Power | 3.6 kVA |
| Rated Output Power | 3.6 kW |
| Rated PV Input Voltage | 360 V |
| Start-Up Voltage | 130 V |
| Strings per MPPT | 1 |
| Surge Rating | 2*rated (10s) |
| Total Harmonic Distortion | <3 % |
| Transfer Time | 20 ms |
| BMS Communication | RS485, CAN |
|---|---|
| Communication Interface | RS232, RS485 |
| Display | LCD, LED |
| Gross Weight | 39.1 kg |
| Installation Style | Wall-Mounted |
| Monitoring Module | WiFi/GPRS |
| Net Weight | 32.4 kg |
| Package Dimensions | 632 x 570 x 315 mm |
| Parallel Capability | 6 |
| Safety Standard | IEC 62109-1, IEC 62109-2 |
| Topology | Isolated (transformer-based) |
| Cooling | Nature |
|---|---|
| IP Rating | IP65 |
| Operating Altitude | 2000 m |
| Operating Temperature Range | -25 to 60 (>45 derating) °C |
| Relative Humidity | 0-100 % |
Looking up an error code on this FelicityESS T-REX-3KLP1G01? Browse the full list of codes for this device, with the cause and recommended fix for each.
View error codes for this device →



Twenty-five Felicity inverters are IP21 and every SCCM charge controller says indoor wall-mount. IP20, IP21 and IP31 are indoor ratings, and the first digit - the dust one - is the half nobody reads. Here is which listing carries which.
Read: Can I Install a Solar Inverter Outside? What IP21, IP31 and IP65 Really Mean →On IVPS/IVPM models, continuous beep + solid red = fault, output cut; intermittent beeping + flashing red = warning. The number on the LCD is the fix.
Read: Felicity Inverter Beeping? What the Beeps & Red Light Mean →An off-grid house is sized by surge, battery energy and charge current - and the surge row is the one that starts your fridge and your pump. Here are the published figures across the Felicity inverters and batteries, with the arithmetic to use them.
Read: How to Run a Whole House on Solar in Khartoum →3.6 kW — the T-REX-3K6LP1G01 is rated 3.6 kVA and 3.6 kW at 230 V single phase on 50/60 Hz, giving 15.6 A rated and 19.5 A maximum output current. Peak efficiency is 97.5%, European efficiency 96.7%, and surge capacity is twice rated power for 10 s.
4.7 kW is the maximum recommended PV power, split across two MPPT trackers carrying one string each. Each tracker accepts 15+15 A, or 18+18 A on short circuit, and works from 100-500 V — 160-500 V at full load — starting at 130 V and never exceeding a 550 V maximum PV voltage.
40-60 V lead-acid or Li-Ion packs on its single battery input, charged and discharged at up to 100 A and 3.6 kW. The charge algorithm self-adapts to the pack's own BMS over RS485 or CAN, and the grid can charge the same bank at up to 100 A through a 40 A maximum AC input.
20 ms. Backup output is rated 3.6 kW with a 30 A maximum output current at 230 V, the same 30 A that is the maximum AC pass-through. Anti-islanding, GFCI, insulation resistance detection and ground fault current monitoring are all built in.