13 kW of PV across two MPPT trackers
Maximum recommended PV power is 13 kW on a 10 kW inverter, split over two MPPT trackers that accept 15+15 A of input current, 18+18 A of short-circuit current and one string each.

A 10 kW three-phase hybrid inverter built around two MPPT trackers over a 200-850 V window, 13 kW of recommended PV, 200 A of battery charge and discharge, and a 38.9 kg IP65 wall-mounted chassis.
In stock
The Felicity Solar T-REX-10KLP3G01 is a 10 kW three-phase hybrid solar inverter that accepts up to 13 kW of PV across two MPPT trackers, charges and discharges a 40-60 V battery bank at 200 A, and delivers 10 kVA of maximum apparent power at 230 V per phase with a 97.6% maximum efficiency. Each tracker carries one string from a 180 V start-up across a 200-850 V window, holds full load from 450 to 850 V and takes 15+15 A up to the 900 V maximum PV voltage. AC output is 230 V per phase and 400 V line on 3L+N+PE wiring, rated at 14.5 A, peaking at 18 A and 30 A in backup, with under 3% THD and a 20 ms transfer time. Two battery inputs take Lead-Acid and Li-Ion, self-adapting to the BMS over RS485 and CAN, and AC charging also reaches 200 A. European efficiency is 97% and MPPT efficiency 99.9%. The wall-mounted IP65 chassis measures 655 x 475 x 266 mm, weighs 38.9 kg net, runs from -25 to 60 °C and parallels up to 10 units. We are the authorised Felicity Solar distributor and supply it with a 2 Years warranty.
Specifications last updated 23 July 2026
| AC Output Line Voltage | 400 V |
|---|---|
| AC Output Voltage | 230 V |
| AC Rated Output Current | 14.5 A |
| AC Wiring Mode | 3L+N+PE |
| Backup Max Output Current | 30 A |
| Backup Rated Output Power | 10 kW |
| Battery Inputs | 2 |
| Battery Type | Lead-Acid, Li-Ion |
| Battery Voltage Range | 40-60 V |
| Charge Algorithm | Self-Adaption to BMS |
| DC Switch | Yes |
| European Efficiency | 97 % |
| Grid Frequency Range (50 Hz) | 45-55 Hz |
| Grid Frequency Range (60 Hz) | 55-65 Hz |
| Grid Regulation | VDE-AR-N 4105, G99/1, EN50549-1, CEI 0-21, AS 4777.2, NRS 097-2-1 |
| Ground Fault Current Monitoring | Yes |
| Input Voltage Range | 184-264.5 V |
| MPPT Efficiency | 99.9 % |
| MPPT Full-Load Voltage Range | 450-850 V |
| MPPT Trackers | 2 |
| MPPT Voltage Range | 200-850 V |
| Max AC Charge Current | 200 A |
| Max AC Input Current | 30 A |
| Max AC Output Power | 10 kW |
| Max AC Pass-Through Current | 30 A |
| Max Apparent Power | 10 kVA |
| Max Charge/Discharge Power | 10 kW |
| Max Charging Current | 200 A |
| Max Discharging Current | 200 A |
| Max Efficiency | 97.6 % |
| Max Output Current | 18 A |
| Max PV Input Current | 15+15 A |
| Max PV Voltage | 900 V |
| Max Recommended PV Power | 13 kW |
| Max Short-Circuit Current | 18+18 A |
| Nominal AC Input Line Voltage | 400 V |
| Nominal AC Input Voltage | 230 V |
| Nominal Input Frequency | 50/60 Hz |
| Output Frequency | 50/60 Hz |
| Output Short-Circuit Protection | Yes |
| Overload Protection | Yes |
| Overvoltage Category (AC) | III |
| Overvoltage Category (DC) | II |
| PV Working Voltage Range | 160-900 V |
| Pass-Through Without Battery | Yes |
| Phase | Three Phase |
| Power Factor | >0.99 |
| Power Factor Adjustment Range | 0.8 leading to 0.8 lagging |
| Protection | Output Over Current Protection, Output Over Power Protection, Output Short-Circuit Protection, Anti-islanding Protection, GFCI Protection, Insulation Resistor Detection |
| Rated Apparent Output Power | 10 kVA |
| Rated Output Power | 10 kW |
| Rated PV Input Voltage | 720 V |
| Start-Up Voltage | 180 V |
| Strings per MPPT | 1 |
| Surge Protection Level (AC) | II |
| Surge Rating | 2*rated (10s) |
| Total Harmonic Distortion | <3 % |
| Transfer Time | 20 ms |
| BMS Communication | RS485, CAN |
|---|---|
| Communication Interface | RS232, RS485 |
| Display | LCD, LED |
| Gross Weight | 47.1 kg |
| Installation Style | Wall-Mounted |
| Monitoring Module | WiFi/GPRS |
| Net Weight | 38.9 kg |
| Package Dimensions | 792 x 597 x 351 mm |
| Parallel Capability | 10 |
| Safety Standard | IEC 62109-1, IEC 62109-2, IEC 62040-1 |
| Topology | Non-Isolated |
| Cooling | Smart Cooling |
|---|---|
| IP Rating | IP65 |
| Operating Altitude | 2000 m |
| Operating Temperature Range | -25 to 60 (>45 derating) °C |
| Relative Humidity | 0-100 % |
Looking up an error code on this FelicityESS T-REX-10KLP3G01? Browse the full list of codes for this device, with the cause and recommended fix for each.
View error codes for this device →



Inverter cutting out on hot afternoons? Error 18, T-REX 35/F35, E-CHO E12/E13, MPPT 87 and battery C09 — the official Felicity heat codes and their fixes.
Read: Felicity Inverter Overheating? Error 18 & Heat Codes →Twenty-five Felicity inverters are IP21 and every SCCM charge controller says indoor wall-mount. IP20, IP21 and IP31 are indoor ratings, and the first digit - the dust one - is the half nobody reads. Here is which listing carries which.
Read: Can I Install a Solar Inverter Outside? What IP21, IP31 and IP65 Really Mean →An off-grid house is sized by surge, battery energy and charge current - and the surge row is the one that starts your fridge and your pump. Here are the published figures across the Felicity inverters and batteries, with the arithmetic to use them.
Read: How to Run a Whole House on Solar in Khartoum →13 kW is the maximum recommended PV power, spread over two MPPT trackers that take 15+15 A of input current and 18+18 A of short-circuit current, one string each. The PV working range is 160-900 V, tracking runs from 200 to 850 V, full load from 450 to 850 V, rated PV input voltage is 720 V and the unit starts at 180 V.
200 A is both the maximum charging current and the maximum discharging current, into a 40-60 V bank across two battery inputs, for a maximum charge and discharge power of 10 kW. AC charging also reaches 200 A, the charge algorithm self-adapts to the BMS over RS485 and CAN, and Lead-Acid and Li-Ion are both supported.
10 kW rated output power and 10 kVA maximum apparent power, three-phase at 230 V per phase and 400 V line on 3L+N+PE wiring. Rated current is 14.5 A, maximum output current 18 A and backup current 30 A, with twice rated power for 10 s of surge, THD below 3%, a power factor above 0.99 adjustable from 0.8 leading to 0.8 lagging, and a 20 ms transfer time. On the AC input it accepts 184-264.5 V at up to 30 A, passes through even without a battery, runs at 50/60 Hz across 45-55 Hz and 55-65 Hz grid windows, and is set for the VDE-AR-N 4105, EN50549-1, CEI 0-21, AS 4777.2 and NRS 097-2-1 grid codes. It is certified to IEC 62109-1, IEC 62109-2 and IEC 62040-1.
IP65 is the enclosure rating, so the wall-mounted 655 x 475 x 266 mm chassis works outdoors from -25 to 60 °C with derating above 45 °C, in 0-100% relative humidity and up to 2000 m of altitude, cooled by smart cooling. It weighs 38.9 kg net and 47.1 kg gross, ships in a 792 x 597 x 351 mm package, and up to 10 units can be paralleled. The non-isolated unit carries an LCD and LED display, RS232 and RS485 interfaces, a WiFi or GPRS monitoring module, overvoltage category III on AC and II on DC, and surge protection level II.