
Felicity Solar IVBM8048P1G1 8kW Single-Phase Off-Grid Solar Inverter
The Felicity Solar IVBM8048P1G1 is an 8 kW single-phase off-grid inverter running on a 48 V battery bank, rated 8 kW / 8 kVA at 230 V with 40 A maximum output current. Peak efficiency is 94.5%, above 95% in line mode.
- Rated Output Power: 8 kW
- Max Efficiency: 94.5 %
- Max PV Input Power: 5+5 kW
- Battery Voltage Range: 42-60 V
In stock
Felicity Solar IVBM8048P1G1 8kW Single-Phase Off-Grid Solar Inverter features
About the Felicity Solar IVBM8048P1G1 8kW Single-Phase Off-Grid Solar Inverter
The Felicity Solar IVBM8048P1G1 is an 8 kW single-phase off-grid solar inverter built around a 48 V battery bank. It delivers 8 kW / 8 kVA of continuous output at 230 V and 50/60 Hz, up to 40 A, at a peak efficiency of 94.5% and above 95% in line mode, with a 10 ms transfer time in UPS mode. A single MPPT tracker works from 100-450 V and takes two strings at 20+20 A, while charging reaches 150 A from solar, from the grid, or from a generator drawing up to 32 A. The low-frequency topology holds twice rated power for 5 seconds and starts motor loads. Battery support covers AGM, flooded, lithium-ion and self-defined profiles across 42-60 V, with RS485 and CAN BMS communication, built-in Wi-Fi monitoring and an LCD and LED display. The IP65 wall-mounted unit weighs 24.3 kg net, measures 490 x 189.2 x 525 mm, and runs from 0 to 50 C. Six units parallel with a battery fitted. We supply it as an authorised Felicity Solar distributor.
Specifications last updated 23 July 2026
Felicity Solar IVBM8048P1G1 8kW Single-Phase Off-Grid Solar Inverter full specifications
Electrical
| AC Output Voltage | 230 V |
|---|---|
| AC Wiring Mode | L+N+PE |
| Backup Max Output Current | 40 A |
| Backup Rated Output Power | 8 kW |
| Battery Inputs | 1 |
| Battery Type | AGM, Flooded, Li-Ion, Self-Defined |
| Battery Voltage Range | 42-60 V |
| Bulk Charging Voltage | 56.4 V |
| Charge Algorithm | Three-Stage: Boost CC, Boost CV, Float |
| Float Charging Voltage | 54 V |
| High DC Input Recovery Voltage | 56.4 V |
| High Frequency Disconnect | 65 Hz |
| High Frequency Reconnect | 63 Hz |
| High Line Disconnect Voltage | 280 V |
| High Line Reconnect Voltage | 270 V |
| Input Voltage Range | 90-280 V |
| Input Voltage Range (UPS Mode) | 170-280 V |
| Input Voltage Waveform | Sinusoidal (utility or generator) |
| Line Mode Efficiency | >95 % |
| Line Mode Output Waveform | Same As Input Waveform |
| Low DC Shutdown (<50% Load) | 43 V |
| Low DC Shutdown (>50% Load) | 42 V |
| Low Frequency Disconnect | 40 Hz |
| Low Frequency Reconnect | 42 Hz |
| Low Line Disconnect (Appliance Mode) | 90 V |
| Low Line Disconnect (UPS Mode) | 170 V |
| Low Line Reconnect (Appliance Mode) | 100 V |
| Low Line Reconnect (UPS Mode) | 180 V |
| Low-Battery Recovery (<50% Load) | 47 V |
| Low-Battery Recovery (>50% Load) | 46 V |
| MPPT Trackers | 1 |
| MPPT Voltage Range | 100-450 V |
| Max AC Charge Current | 150 A |
| Max AC Input Voltage | 280 V |
| Max AC Pass-Through Current | 53 A |
| Max Charging Current | 150 A |
| Max Charging Voltage | 60 V |
| Max Efficiency | 94.5 % |
| Max Generator Input Current | 32 A |
| Max Inverter/Rectifier Current | 40 A |
| Max Output Current | 40 A |
| Max PV Input Current | 20+20 A |
| Max PV Input Power | 5+5 kW |
| Max PV Voltage | 450 V |
| Max Smart Load Output Current | 40 A |
| Max Solar Charging Current | 150 A |
| Motor Start Capable | Yes |
| Nominal AC Input Voltage | 230 V |
| Nominal DC Input Voltage | 48 V |
| Nominal Input Frequency | 50/60 Hz |
| Output Frequency | 50/60 Hz |
| Output Short-Circuit Protection | Yes |
| Output Voltage Regulation | 5 % |
| Output Voltage Waveform | Pure Sine Wave |
| Overload Protection | Yes |
| Overload Trip Time (>105% Load) | 10 s |
| Overload Trip Time (>150% Load) | 5 s |
| PV Working Voltage Range | 90-450 V |
| Pass-Through Without Battery | Yes |
| Phase | Single Phase |
| Protection | Overload Protection, Over Temperature Protection, Short Circuit Protection |
| Rated Apparent Output Power | 8 kVA |
| Rated Output Power | 8 kW |
| Short-Circuit Protection (Battery Mode) | Electronic Circuit |
| Short-Circuit Protection (Line Mode) | Circuit Breaker |
| Start-Up Voltage | 160 V |
| Strings per MPPT | 2 |
| Surge Rating | 2*rated (5s) |
| Transfer Time (Appliance Mode) | 20 ms |
| Transfer Time (UPS Mode) | 10 ms |
Mechanical
| BMS Communication | RS485, CAN |
|---|---|
| Communication Interface | RS232, RS485, CAN |
| Display | LCD, LED |
| Gross Weight | 28.3 kg |
| Installation Style | Wall-Mounted |
| Monitoring Module | Built-In WiFi |
| Net Weight | 24.3 kg |
| Package Dimensions | 572 x 267 x 597 mm |
| Parallel Capability | 6 (battery required) |
| Topology | Low-Frequency |
Environmental
| Cooling | Intelligent Air Cooling |
|---|---|
| IP Rating | IP65 |
| Operating Temperature Range | 0-50 °C |
| Storage Temperature | -15 to 60 °C |
Related Products

Felicity Solar IVBM10048P1G1 10kW Single-Phase Off-Grid Solar Inverter
- Rated Output Power:10 kW
- Max Efficiency:94.5 %

Felicity Solar IVGM8KLP1G1 8kW Single-Phase Hybrid Solar Inverter
- Rated Output Power:8 kW
- Max Efficiency:97.6 %

Felicity Solar IVGM8KLP2G1 8kW Single-Phase Hybrid Solar Inverter
- Rated Output Power:8 kW
- Max Efficiency:97.6 %

Felicity Solar IVGM7K6LP1G1 7.6kW Single-Phase Hybrid Solar Inverter
- Rated Output Power:7.6 kW
- Max Efficiency:97.6 %
Related Articles
Can Solar Replace the Generator in Beirut?
The honest answer is that solar first replaces the hours the engine runs, not the engine. Here is what the Felicity records actually publish about pairing with a generator - the input windows, the generator current rows and the charge current that decides how long it runs.
Read: Can Solar Replace the Generator in Beirut? →Best Inverter for Power Cuts in Baghdad and Basra
Transfer time is the gap your fridge and router run on nothing, and the input voltage window decides whether the inverter accepts weak mains at all. Both are published per model across the Felicity range - here they are, side by side.
Read: Best Inverter for Power Cuts in Baghdad and Basra →Can I Install a Solar Inverter Outside? What IP21, IP31 and IP65 Really Mean
Twenty-five Felicity inverters are IP21 and every SCCM charge controller says indoor wall-mount. IP20, IP21 and IP31 are indoor ratings, and the first digit - the dust one - is the half nobody reads. Here is which listing carries which.
Read: Can I Install a Solar Inverter Outside? What IP21, IP31 and IP65 Really Mean →