The Felicity Solar IVGM12KLP3G1 is a 12 kW three-phase hybrid inverter that peaks at 13.2 kVA apparent power and converts at up to 97.6% efficiency. It accepts 18 kW of PV across two MPPT trackers and charges a 40-60 V battery bank at up to 240 A.
- Rated Output Power: 12 kW
- Max Apparent Power: 13.2 kVA
- Max Efficiency: 97.6 %
- Max PV Input Power: 18 kW
Models in the IVGM10KLP3G1 – IVGM20KLP3G1 family
What sets the IVGM12KLP3G1 apart from the other 6 models in the family: AC Rated Output Current 17.4 A; Backup Rated Output Power 12 kW; MPPT Full-Load Voltage Range 347-800 V; Max AC Input Current 19.2 A; Max AC Pass-Through Current 45 A; Max Apparent Power 13.2 kVA; Max Charging Current 240 A; Max Discharging Current 240 A.
In stock
- Delivered within 3 business days, door to door, to every market we serve.
- Dispatched the same business day for an order placed before 21:00 (Dubai time), or the next business day after.
- Delivery charge: free
- 2-year warranty
Felicity Solar IVGM12KLP3G1 12kW Three-Phase Hybrid Solar Inverter features
Two MPPT trackers accept 18 kW of PV, 800 V maximum input, 26+26 A and 2+2 strings, tracking 160-650 V from a 160 V start-up
97.6% maximum efficiency with total harmonic distortion under 3% and a 0.8 leading to 0.8 lagging power factor range
Two battery inputs for lead-acid or Li-ion at 40-60 V, 240 A charging and 240 A discharging, with RS485 and CAN BMS communication
20 ms transfer time, 45 A AC pass-through, twice rated power for 10 seconds and 65 A output overcurrent protection
IP65 enclosure with smart cooling, LCD touch screen and WiFi/4G monitoring, -25°C to 60°C operation and up to 10 units in parallel
About the Felicity Solar IVGM12KLP3G1 12kW Three-Phase Hybrid Solar Inverter
The Felicity Solar IVGM12KLP3G1 is a 12 kW three-phase hybrid solar inverter: it delivers 12 kW of rated output and 13.2 kVA of apparent power on a 380-400 V line, converts at up to 97.6% maximum efficiency, accepts 18 kW of PV across two MPPT trackers, and charges a 40-60 V battery bank at up to 240 A. Each tracker takes two strings at 26+26 A and 800 V maximum, tracks from 160 V to 650 V and holds full load between 347 V and 800 V. On the AC side the unit gives 17.4 A rated and 19.2 A maximum per phase over a 3L+N+PE connection, passes through 45 A, holds twice rated power for 10 seconds, transfers in 20 ms and keeps total harmonic distortion below 3%. Two battery inputs accept lead-acid or Li-ion banks with RS485 and CAN BMS communication and charging that self-adapts to the BMS. IP65 sealing, smart cooling, an LCD touch screen and WiFi/4G monitoring cover installations from -25°C to 60°C, derating above 45°C, and up to 10 units run in parallel. We supply it as an authorised Felicity Solar distributor.
Specifications last updated 23 March 2026
Felicity Solar IVGM12KLP3G1 12kW Three-Phase Hybrid Solar Inverter full specifications
Electrical(48)
| AC Output Line Voltage | 380-400 V |
|---|---|
| AC Output Voltage | 220-230 V |
| AC Rated Output Current | 17.4 A |
| AC Wiring Mode | 3L+N+PE |
| Backup Rated Output Power | 12 kW |
| Battery Inputs | 2 |
| Battery Type | Lead-Acid, Li-Ion |
| Battery Voltage Range | 40-60 V |
| Charge Algorithm | Self-Adaption to BMS |
| DC Switch | Yes |
| Grid Frequency Range (50 Hz) | 45-55 Hz |
| Grid Frequency Range (60 Hz) | 55-65 Hz |
| Grid Regulation | NRS 097-2-1, VDE4105, EN50549-1, AS 4777.2, GB/T 34120, GB/T 34133, GB/T 34129 |
| Ground Fault Current Monitoring | Yes |
| Input Voltage Range | 184-264.5 V |
| MPPT Full-Load Voltage Range | 347-800 V |
| MPPT Trackers | 2 |
| MPPT Voltage Range | 160-650 V |
| Max AC Input Current | 19.2 A |
| Max AC Pass-Through Current | 45 A |
| Max Apparent Power | 13.2 kVA |
| Max Charging Current | 240 A |
| Max Discharging Current | 240 A |
| Max Efficiency | 97.6 % |
| Max Output Current | 19.2 A |
|---|---|
| Max Output Overcurrent Protection | 65 A |
| Max PV Input Current | 26+26 A |
| Max PV Input Power | 18 kW |
| Max PV Voltage | 800 V |
| Max Short-Circuit Current | 39+39 A |
| Nominal AC Input Line Voltage | 380-400 V |
| Nominal AC Input Voltage | 220-230 V |
| Nominal Input Frequency | 50/60 Hz |
| Output Frequency | 50/60 Hz |
| Output Short-Circuit Protection | Yes |
| Overload Protection | Yes |
| Phase | Three Phase |
| Power Factor Adjustment Range | 0.8 leading to 0.8 lagging |
| Protection | DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, Thermal Protection, DC Terminal Insulation Impedance Monitoring, DC Component Monitoring, Ground Fault Current Monitoring, Arc Fault Circuit Interrupter (AFCI), Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch, Overvoltage Load Drop Protection, Residual Current (RCD) Detection |
| Rated Apparent Output Power | 12 kVA |
| Rated Output Power | 12 kW |
| Rated PV Input Voltage | 550 V |
| Start-Up Voltage | 160 V |
| Strings per MPPT | 2+2 |
| Surge Protection Level (AC) | II |
| Surge Rating | 2*rated (10s) |
| Total Harmonic Distortion | <3 % |
| Transfer Time | 20 ms |
Mechanical(10)
| BMS Communication | RS485, CAN |
|---|---|
| Communication Interface | RS232, RS485 |
| Display | LCD Touch Screen |
| Gross Weight | 60.2 kg |
| Monitoring Module | WiFi/4G |
| Net Weight | 48.7 kg |
| Package Dimensions | 889 x 566 x 397 mm |
| Parallel Capability | 10 |
| Safety Standard | IEC/EN 62109-1, IEC/EN 62109-2 |
| Topology | Non-Isolated |
Environmental(3)
| Cooling | Smart Cooling |
|---|---|
| IP Rating | IP65 |
| Operating Temperature Range | -25 to 60 (>45 derating) °C |
Certifications(4)
- IEC 62109-1
- EN 62109-1
- IEC 62109-2
- EN 62109-2
Downloads & support
Frequently Asked Questions
What output power does the Felicity IVGM12KLP3G1 deliver?
The IVGM12KLP3G1 is rated at 12 kW output, 12 kW of it available in backup, with 13.2 kVA maximum apparent power. It supplies 17.4 A rated and 19.2 A maximum per phase on a 380-400 V three-phase line (220-230 V per phase, 3L+N+PE), at 50/60 Hz, and sustains twice rated power for 10 seconds.
How much solar can the IVGM12KLP3G1 take, and how many MPPTs does it have?
It accepts up to 18 kW of PV on two MPPT trackers, two strings each (2+2), at 26+26 A input current and 39+39 A short-circuit current. Maximum PV voltage is 800 V, the MPPT range is 160-650 V with full load held from 347 V to 800 V, and the rated PV input voltage is 550 V. The unit starts up at 160 V.
Which batteries work with the IVGM12KLP3G1?
The inverter has two battery inputs for lead-acid or Li-ion banks in a 40-60 V range, charging and discharging at up to 240 A. It talks to the battery over RS485 and CAN, and its charge algorithm self-adapts to the BMS, so a lithium pack sets its own charging profile.
Can the IVGM12KLP3G1 be installed outdoors, and what does it weigh?
Yes. The enclosure is rated IP65 with smart cooling and works from -25°C to 60°C, derating above 45°C. It measures 750 x 450 x 268 mm and weighs 48.7 kg net, 60.2 kg gross in a 889 x 566 x 397 mm carton. It is built to IEC 62109-1, EN 62109-1, IEC 62109-2 and EN 62109-2, with grid compliance including VDE4105, EN50549-1, AS 4777.2 and NRS 097-2-1.