Felicity Solar Hybrid Inverters 12 kW IVGM12KLP3G1
The Felicity Solar IVGM12KLP3G1 is a 12 kW three-phase hybrid inverter that peaks at 13.2 kVA apparent power and converts at up to 97.6% efficiency. It accepts 18 kW of PV across two MPPT trackers and charges a 40-60 V battery bank at up to 240 A.
Models and prices
- IVGM12KLP3G1AED 6,600incl. VAT
Technical Specifications
| Parameter | IVGM12KLP3G1 |
|---|---|
| Performance & Electrical | |
| AC Output Line Voltage | 380-400 V |
| AC Output Voltage | 220-230 V |
| AC Rated Output Current | 17.4 A |
| AC Wiring Mode | 3L+N+PE |
| Backup Rated Output Power | 12 kW |
| Battery Inputs | 2 |
| Battery Type | Lead-Acid, Li-Ion |
| Battery Voltage Range | 40-60 V |
| Charge Algorithm | Self-Adaption to BMS |
| DC Switch | Yes |
| Grid Frequency Range (50 Hz) | 45-55 Hz |
| Grid Frequency Range (60 Hz) | 55-65 Hz |
| Grid Regulation | NRS 097-2-1, VDE4105, EN50549-1, AS 4777.2, GB/T 34120, GB/T 34133, GB/T 34129 |
| Ground Fault Current Monitoring | Yes |
| Input Voltage Range | 184-264.5 V |
| MPPT Full-Load Voltage Range | 347-800 V |
| MPPT Trackers | 2 |
| MPPT Voltage Range | 160-650 V |
| Max AC Input Current | 19.2 A |
| Max AC Pass-Through Current | 45 A |
| Max Apparent Power | 13.2 kVA |
| Max Charging Current | 240 A |
| Max Discharging Current | 240 A |
| Max Efficiency | 97.6% |
| Max Output Current | 19.2 A |
| Max Output Overcurrent Protection | 65 A |
| Max PV Input Current | 26+26 A |
| Max PV Input Power | 18 kW |
| Max PV Voltage | 800 V |
| Max Short-Circuit Current | 39+39 A |
| Nominal AC Input Line Voltage | 380-400 V |
| Nominal AC Input Voltage | 220-230 V |
| Nominal Input Frequency | 50/60 Hz |
| Output Frequency | 50/60 Hz |
| Output Short-Circuit Protection | Yes |
| Overload Protection | Yes |
| Phase | Three Phase |
| Power Factor Adjustment Range | 0.8 leading to 0.8 lagging |
| Protection | DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, Thermal Protection, DC Terminal Insulation Impedance Monitoring, DC Component Monitoring, Ground Fault Current Monitoring, Arc Fault Circuit Interrupter (AFCI), Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch, Overvoltage Load Drop Protection, Residual Current (RCD) Detection |
| Rated Apparent Output Power | 12 kVA |
| Rated Output Power | 12 kW |
| Rated PV Input Voltage | 550 V |
| Start-Up Voltage | 160 V |
| Strings per MPPT | 2+2 |
| Surge Protection Level (AC) | II |
| Surge Protection Level (DC) | II |
| Surge Rating | 2*rated (10s) |
| Total Harmonic Distortion | <3% |
| Transfer Time | 20 ms |
| Build & Interfaces | |
| BMS Communication | RS485, CAN |
| Communication Interface | RS232, RS485 |
| Display | LCD Touch Screen |
| Gross Weight | 60.2 kg |
| Monitoring Module | WiFi/4G |
| Net Weight | 48.7 kg |
| Package Dimensions | 889 x 566 x 397 mm |
| Parallel Capability | 10 |
| Safety Standard | IEC/EN 62109-1, IEC/EN 62109-2 |
| Topology | Non-Isolated |
| Operating Environment | |
| Cooling | Smart Cooling |
| IP Rating | IP65 |
| Operating Temperature Range | -25 to 60 (>45 derating) °C |
Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.
Availability & grid compliance in the UAE
| Market | UAE |
|---|---|
| Grid authority / regulator | DEWA, ADDC, SEWA |
| Quotation currency | AED |
| Support hours timezone | Asia/Dubai |
| Main cities | Dubai, Abu Dhabi, Sharjah, Ajman, Ras Al Khaimah |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in the UAE that rests with the local authorities (DEWA, ADDC, SEWA). Confirm the grid code, import requirements and any local certification with them, or with us, before you order.
Key Features & Technical Highlights
- 12 kW rated output and 12 kW backup output, 13.2 kVA maximum apparent power, 17.4 A rated and 19.2 A maximum per phase on a 380-400 V three-phase line
- Two MPPT trackers accept 18 kW of PV, 800 V maximum input, 26+26 A and 2+2 strings, tracking 160-650 V from a 160 V start-up
- 97.6% maximum efficiency with total harmonic distortion under 3% and a 0.8 leading to 0.8 lagging power factor range
- Two battery inputs for lead-acid or Li-ion at 40-60 V, 240 A charging and 240 A discharging, with RS485 and CAN BMS communication
- 20 ms transfer time, 45 A AC pass-through, twice rated power for 10 seconds and 65 A output overcurrent protection
- IP65 enclosure with smart cooling, LCD touch screen and WiFi/4G monitoring, -25°C to 60°C operation and up to 10 units in parallel
Frequently Asked Questions
What output power does the Felicity IVGM12KLP3G1 deliver?
The IVGM12KLP3G1 is rated at 12 kW output, 12 kW of it available in backup, with 13.2 kVA maximum apparent power. It supplies 17.4 A rated and 19.2 A maximum per phase on a 380-400 V three-phase line (220-230 V per phase, 3L+N+PE), at 50/60 Hz, and sustains twice rated power for 10 seconds.
How much solar can the IVGM12KLP3G1 take, and how many MPPTs does it have?
It accepts up to 18 kW of PV on two MPPT trackers, two strings each (2+2), at 26+26 A input current and 39+39 A short-circuit current. Maximum PV voltage is 800 V, the MPPT range is 160-650 V with full load held from 347 V to 800 V, and the rated PV input voltage is 550 V. The unit starts up at 160 V.
Which batteries work with the IVGM12KLP3G1?
The inverter has two battery inputs for lead-acid or Li-ion banks in a 40-60 V range, charging and discharging at up to 240 A. It talks to the battery over RS485 and CAN, and its charge algorithm self-adapts to the BMS, so a lithium pack sets its own charging profile.
Can the IVGM12KLP3G1 be installed outdoors, and what does it weigh?
Yes. The enclosure is rated IP65 with smart cooling and works from -25°C to 60°C, derating above 45°C. It measures 750 x 450 x 268 mm and weighs 48.7 kg net, 60.2 kg gross in a 889 x 566 x 397 mm carton. It is built to IEC 62109-1, EN 62109-1, IEC 62109-2 and EN 62109-2, with grid compliance including VDE4105, EN50549-1, AS 4777.2 and NRS 097-2-1.