A 100 A MPPT solar charge controller that takes 195 V of panel input and up to 5500 W of array on a 48 V bank, tracking from 60-170 VDC at 98% efficiency.

  • Maximum Charge Current: 100 A
  • Maximum Efficiency: 98 %
  • Nominal System Voltage: 12V/24V/48V (Auto)
AED 500incl. VAT

In stock

  • Delivered within 3 business days, door to door, to every market we serve.
  • Dispatched the same business day for an order placed before 21:00 (Dubai time), or the next business day after.
  • Delivery charge: AED 30
  • 2-year warranty

Felicity Solar SCCM10048-II 100A Solar Charge Controller features

  • 100 A maximum charge current

    The SCCM10048-II delivers up to 100 A of charge current into a 12 V, 24 V or 48 V battery bank it detects automatically.

  • 195 V maximum PV input voltage

    The solar input accepts an array voltage of up to 195 V and begins tracking from a PV start-up voltage of 15 V.

  • 5500 W of array on a 48 V bank

    Array capacity follows battery voltage: 1375 W at 12 V, 2750 W at 24 V and 5500 W at 48 V.

  • 98% maximum conversion efficiency

    Peak efficiency reaches 98%, with MPPT tracking from 60-170 VDC at 48 V, 30-170 VDC at 24 V and 15-170 VDC at 12 V.

  • 4500 Watts of surge protection per port

    Each port carries 4500 Watts of transient surge protection, and the 3-Step charge profile compensates -5 mV/°C/cell referenced at 25°C.

  • CAN, RS485 and built-in WiFi

    CAN handles parallel operation, RS485 carries BMS data and WiFi is built in, with readings on the built-in LCD.

About the Felicity Solar SCCM10048-II 100A Solar Charge Controller

The Felicity Solar SCCM10048-II is a 100 A MPPT solar charge controller for 12 V, 24 V and 48 V battery banks, which it detects automatically. It accepts up to 195 V of PV input voltage and up to 5500 W of solar array on a 48 V bank, converting at a maximum efficiency of 98%. MPPT tracking runs from 60-170 VDC at 48 V, 30-170 VDC at 24 V and 15-170 VDC at 12 V, above a 15 V PV start-up threshold, with array limits of 1375 W at 12 V and 2750 W at 24 V. A 3-Step charging profile with -5 mV/°C/cell temperature compensation referenced at 25°C protects the bank, and every port carries 4500 Watts of transient surge protection. CAN handles parallel operation, RS485 carries BMS traffic and WiFi is built in, alongside a built-in LCD. The unit measures 360 x 250 x 156 mm, weighs 5.1 kg and wall-mounts indoors in an IP20 (Indoor & Vented) enclosure rated 0°C to 55°C. We are an authorised Felicity Solar distributor and supply the SCCM10048-II from our own stock; warranty is 2 Years.

Specifications last updated 23 March 2026

Felicity Solar SCCM10048-II 100A Solar Charge Controller full specifications

Electrical(25)

Maximum Solar Input Voltage195V
Maximum Charge Current100 A
Nominal System Voltage12V/24V/48V (Auto)
PV Array MPPT Voltage Range12 VDC: 15-170 VDC / 24 VDC: 30-170 VDC / 48 VDC: 60-170 VDC
Maximum Input Power12V - 1375W / 24V - 2750W / 48V - 5500W
PV Start-up Voltage15V
Charging Algorithm3-Step
Charging StagesBulk, Absorption, Float
Temperature Compensation Coefficient-5 mV/°C/cell @ 25°C ref
CommunicationCAN (parallel), RS485 (BMS), WiFi (built-in)
Maximum Efficiency98 %
Transient Surge Protection4500 Watts / port
System Nominal Voltage12-48 V
Max Charge Current100 A
Max PV Input Power1375-5500 W
Max PV Input Voltage195 V
MPPT Voltage Range15-170 V
Max Efficiency98 %
Supported Battery TypesAGM, Gel, Flooded, Lithium, User-Defined
Temperature Compensation Coefficient-5 mV/°C/cell (25 °C ref.)
Temperature Compensation Range0-50 °C
Surge Protection4500 W/port
Protection FeaturesSolar high voltage disconnect, Solar high voltage reconnect, Battery high voltage disconnect, Battery high voltage reconnect, High temperature disconnect, High temperature reconnect
Operating Temperature0-55 °C
Storage Temperature Range-25 to 75 °C

Mechanical(9)

Product Size (W x H x D,mm)360x250x156 mm
DisplayLCD (built-in)
InstallationIndoor wall-mount
Dimensions (A x B)255 x 197 mm
DisplayLCD
Communication InterfaceUSB, MODBUS
Overall Dimensions360 x 250 x 156 mm
Weight5.1 kg
InstallationWall-Mounted

Environmental(9)

Humidity0%-90%RH(No condensing)
Storage Temperature- 25°C to 75°C
Temperature compensation range0 °C to +50 °C
Ambient Temperature Range0°C to +55°C
Enclosure RatingIP20 (Indoor & Vented)
Warranty2 Years
Operating Temperature0°C to 55°C
IP RatingIP20
Relative Humidity0-90 (non-condensing) %

Certifications(2)

  • CE
  • ISO9001

Downloads & support

Frequently Asked Questions

How many amps can the SCCM10048-II charge at?

100 A is the maximum charge current of the SCCM10048-II, delivered into a 12 V, 24 V or 48 V bank that the controller detects automatically. Charging follows a 3-Step profile at a maximum efficiency of 98%.

What is the biggest solar array the SCCM10048-II can take?

195 V is the maximum PV input voltage, and array power is capped at 1375 W on a 12 V bank, 2750 W on 24 V and 5500 W on 48 V. Tracking starts at a PV start-up voltage of 15 V.

What is the MPPT voltage range of the SCCM10048-II?

60-170 VDC on a 48 V battery bank, 30-170 VDC on 24 V and 15-170 VDC on 12 V. The PV start-up voltage is 15 V and the absolute maximum solar input is 195 V.

What size is the SCCM10048-II and how is it mounted?

360 x 250 x 156 mm and 5.1 kg, wall-mounted indoors. The IP20 (Indoor & Vented) enclosure runs from 0°C to 55°C in 0%-90%RH non-condensing air, and stores from - 25°C to 75°C.