Felicity Solar FLA48300 51.2V 15kWh LiFePO4 Battery
Wall- or floor-mounted at 135 kg, the FLA48300 puts 300 Ah and 15 kWh on a 51.2 V bus and stacks to 15 units for 225 kWh.
- Nominal Energy: 15 kWh
- Nominal Capacity: 300 Ah
- Nominal Voltage: 51.2 V
- Cycle Life: 6000
In stock
Felicity Solar FLA48300 51.2V 15kWh LiFePO4 Battery features
About the Felicity Solar FLA48300 51.2V 15kWh LiFePO4 Battery
The Felicity Solar FLA48300 is a 51.2 V LiFePO4 battery rated 300 Ah and 15 kWh of nominal energy, sustaining 150 A of continuous charge and discharge current at a recommended 120 A, with a 15-second ceiling of 200 A and 10,000 W, and paralleling to 15 units for a 225 kWh maximum system capacity. Warranty is 7 Years. The 15 kWh is nominal energy; the depth-of-discharge row stands apart at ≥95%, and rated life is 6,000 cycles. Voltage runs from a 44.8 V cut-off to a 57.6 V charging ceiling. Protection combines a built-in Smart BMS, a breaker and a fuse, CAN and RS485 hand pack data to a compatible inverter, and an LCD reports locally. The cabinet weighs 135 kg and takes either a wall or a floor; packed it is 160 kg in a 635 x 498 x 1150 mm carton, and that packed figure is the one to plan handling around. It is rated IP21, charges from 0 to 55 °C, discharges from -20 to 55 °C, stores at 0-35 °C, tolerates 5-95% humidity and operates below 2000 m. We are an authorised Felicity Solar distributor and supply the FLA48300 from our own stock.
Specifications last updated 17 August 2026
Felicity Solar FLA48300 51.2V 15kWh LiFePO4 Battery full specifications
Electrical
| Battery Type | LiFePO4 |
|---|---|
| Cut-Off Voltage | 44.8 V |
| Cycle Life | 6000 |
| Depth of Discharge | ≥95 % |
| Max Charge/Discharge Power (15 s) | 10000 W |
| Max Charging Voltage | 57.6 V |
| Max Continuous Charge/Discharge Current | 150 A |
| Max Parallel Units | 15 |
| Max System Capacity | 225 kWh |
| Nominal Capacity | 300 Ah |
| Nominal Energy | 15 kWh |
| Nominal Voltage | 51.2 V |
| Operating Voltage | 44.8-57.6 V |
| Peak Charge/Discharge Current (15 s) | 200 A |
| Protection | Built-in Smart BMS, Breaker, Fuse |
| Recommended Charge/Discharge Current | 120 A |
Mechanical
| Communication | CAN, RS485 |
|---|---|
| Display Type | LCD |
| Installation | Wall-Mounted, Floor-Mounted |
| Package Dimensions | 635 x 498 x 1150 mm |
| Package Weight | 160 kg |
Environmental
| Charging Temperature Range | 0-55 °C |
|---|---|
| Discharging Temperature Range | -20 to 55 °C |
| Humidity Range | 5-95 % |
| Operating Altitude | <2000 m |
| Protection Degree | IP21 |
| Storage Temperature Range | 0-35 °C |
Certifications
- UN38.3
- CE-EMC
- IEC 62619
Related Products

Felicity Solar FLA48300TG2 51.2V 15kWh LiFePO4 Battery
- Communication:CAN
- Nominal Energy:15kWh

Felicity Solar LPBF48300 51.2V 15kWh LiFePO4 Battery
- Battery Type:LiFePO4
- Nominal Energy:15kWh 15kWh

Felicity Solar LPBF48300-II 51.2V 15kWh LiFePO4 Battery
- Nominal Energy:15 kWh
- Nominal Capacity:300 Ah

Felicity Solar FLA48280 51.2V 14.3kWh LiFePO4 Battery
- Nominal Energy:14.3 kWh
- Nominal Capacity:280 Ah

Felicity Solar FLA48280TG2-EU 51.2V 14.3kWh Battery
- Nominal Energy:14.3kWh
- Nominal Voltage:51.2V

Felicity Solar FLB48280TG1 51.2V 14.3kWh LiFePO4 Battery
- Nominal Energy:14.3kWh
- Battery Type:LiFePO4

Felicity Solar FLB48280TG1-AU 51.2V 14.3kWh LiFePO4 Battery
- Nominal Energy:14.3kWh
- Battery Type:LiFePO4

Felicity Solar FLB48280TG1-H 51.2V 14.3kWh Battery
- Nominal Energy:14.3kWh
- Nominal Voltage:51.2V
Related Articles
How to Run a Whole House on Solar in Khartoum
An off-grid house is sized by surge, battery energy and charge current - and the surge row is the one that starts your fridge and your pump. Here are the published figures across the Felicity inverters and batteries, with the arithmetic to use them.
Read: How to Run a Whole House on Solar in Khartoum →How to Calculate Your Daily Power Consumption for Off-Grid Solar
Step-by-step guide to calculating daily power consumption in kWh. Includes a load audit worksheet and tips for sizing your off-grid solar system correctly.
Read: How to Calculate Your Daily Power Consumption for Off-Grid Solar →Which Solar Inverter Will Actually Start My Water Pump?
Most pumps that refuse to turn are sitting on an inverter that looked big enough on paper. Here is the one line on the listing that decides it, why the kilowatt figure on the box misleads, and how to turn your pump's own nameplate into a model you can order.
Read: Which Solar Inverter Will Actually Start My Water Pump? →