LUX-E-48100LG03

Batterie14 codes
14 Défaut
C01Battery overvoltage.Défaut
Cause

Battery pack voltage exceeded the upper protection threshold.

Correction recommandée

Restart the unit. if the error persists, contact the repair center.

Source:LUX-E-48100LG03-Lithium-Battery-User-Guide.pdf · page 12
C02Battery undervoltage.Défaut
Cause

Battery pack voltage fell below the lower protection threshold.

Correction recommandée

Restart the unit. if the error persists, contact the repair center.

Source:LUX-E-48100LG03-Lithium-Battery-User-Guide.pdf · page 12
C03Cell overvoltage.Défaut
Cause

An individual cell voltage exceeded the upper protection threshold.

Correction recommandée

Restart the unit. if the error persists, contact the repair center.

Source:LUX-E-48100LG03-Lithium-Battery-User-Guide.pdf · page 12
C04Cell undervoltage.Défaut
Cause

An individual cell voltage fell below the lower protection threshold.

Correction recommandée

Restart the unit. if the error persists, contact the repair center.

Source:LUX-E-48100LG03-Lithium-Battery-User-Guide.pdf · page 12
C05Charge overcurrent.Défaut
Cause

Charging current exceeded the protection threshold.

Correction recommandée

Restart the unit. if the error persists, contact the repair center.

Source:LUX-E-48100LG03-Lithium-Battery-User-Guide.pdf · page 12
C06Discharge overcurrent.Défaut
Cause

Discharging current exceeded the protection threshold.

Correction recommandée

Restart the unit. if the error persists, contact the repair center.

Source:LUX-E-48100LG03-Lithium-Battery-User-Guide.pdf · page 12
C07MOS overtemperature.Défaut
Cause

The inner temperature is over the limitation. Check whether the ambient temperature is too high.

Correction recommandée

Check whether the ambient temperature is too high; allow the unit to cool. if the error persists, return to repair center.

Source:LUX-E-48100LG03-Lithium-Battery-User-Guide.pdf · page 12
C08MOS undertemperature.Défaut
Cause

The internal temperature is lower than the limit range. Check whether the ambient temperature is too low.

Correction recommandée

Check whether the ambient temperature is too low; warm the environment. if the error persists, return to repair center.

Source:LUX-E-48100LG03-Lithium-Battery-User-Guide.pdf · page 12
C09Cell overtemperature.Défaut
Cause

An individual cell temperature exceeded the upper protection threshold.

Correction recommandée

Restart the unit. if the error persists, contact the repair center.

Source:LUX-E-48100LG03-Lithium-Battery-User-Guide.pdf · page 13
C10Cell undertemperature.Défaut
Cause

An individual cell temperature fell below the lower protection threshold.

Correction recommandée

Restart the unit. if the error persists, contact the repair center.

Source:LUX-E-48100LG03-Lithium-Battery-User-Guide.pdf · page 13
C11Abnormal current sampling.Défaut
Cause

BMS detected an abnormal reading from the current-sampling circuit.

Correction recommandée

Restart the unit. if the error persists, contact the repair center.

Source:LUX-E-48100LG03-Lithium-Battery-User-Guide.pdf · page 13
C12Abnormal output impedance.Défaut
Cause

BMS detected abnormal output impedance (e.g. loose/poor connection at output terminals).

Correction recommandée

Restart the unit. if the error persists, contact the repair center.

Source:LUX-E-48100LG03-Lithium-Battery-User-Guide.pdf · page 13
C13Parallel failed.Défaut
Cause

Parallel-connection condition not satisfied. Possible causes: (1) a single unit is configured as part of a parallel system; (2) wires are mis-connected during parallel installation.

Correction recommandée

1. Check if a single unit is wrongly installed to a parallel system. 2. if the error happens during parallel installation, check wires connection. if they are connected correctly, finish parallel installation first, then restart the unit. 3. if the problem remains, please contact your installer.

Source:LUX-E-48100LG03-Lithium-Battery-User-Guide.pdf · page 13
C14Output loss.Défaut
Cause

No output from the battery pack. Possible causes: circuit breaker open, or fuse blown.

Correction recommandée

1. Please check whether the circuit breaker is closed. 2. Please check whether the fuse is normal. 3. Restart the unit. if the error persists, contact the repair center.

Source:LUX-E-48100LG03-Lithium-Battery-User-Guide.pdf · page 13

Compilé à partir des manuels utilisateur officiels FelicityESS. Consultez toujours le manuel de votre appareil et un technicien qualifié avant toute réparation.