Défaut

C14

Output loss.

14 Appareils signalant ce code
C14Output loss.Défaut
Description

Output loss fault. LED pattern: LED1 OFF, LED2 ON, LED3 ON, LED4 ON.

Correction recommandée

1. Check whether the circuit breaker is closed. 2. Check whether the fuse is normal. 3. Restart the unit. if the error persists, contact the repair center.

Source:Felicitysolar FLA12100 12.5Kwh Battery Energy Storage System User Manual.pdf · page 1
C14Output loss.Défauthigh
Description

Battery output is lost - no power being delivered to the load.

Cause

Circuit breaker open or fuse blown.

Correction recommandée

1. Please check whether the circuit breaker is closed; 2. Please check whether the fuse is normal; 3. Restart the unit. if the error persists, contact the repair center.

Source:Felicitysolar FLA48200 48V 200Ah 10kWh Lithium Phosphate Battery User Manual.pdf · page 13
C14Output loss.Critique
Description

BMS detected loss of output from the battery pack (no power on the output side).

Cause

Circuit breaker may be open, or the fuse may be blown.

Correction recommandée

1. Please check whether the circuit breaker is closed. 2. Please check whether the fuse is normal. 3. Restart the unit. if the error persists, contact the repair center.

Source:6peluqppy_66a93554057c8.pdf · page 13
C14C14Défaut
Description

Output loss.

Correction recommandée

1. Please check whether the circuit breaker is closed. 2. Please check whether the fuse is normal. 3. Restart the unit. if the error persists, contact the repair center.

Source:FLA48250-EU_Manual.pdf · page 8
C14Output loss.Défaut
Description

Output loss / no output detected.

Cause

Breaker open, blown fuse, or output path interrupted.

Correction recommandée

1. Please check whether the circuit breaker is closed; 2. Please check whether the fuse is normal; 3. Restart the unit. if the error persists, contact the repair center.

Source:felicitysolar FLA48500 LiFePO4 Battery System for Households User Guide.pdf
C14Ausgangsverlust / Ausgang fehlt.Défaut
Description

Output loss. No output detected at the battery terminals.

Cause

Circuit breaker open, blown fuse, or internal output failure (Sicherung durchgebrannt, Trennschalter offen oder interner Ausgangsfehler).

Correction recommandée

1. Check whether the circuit breaker is closed. 2. Check whether the fuse is normal (the external fuse can be replaced if blown). 3. Restart the unit; if the error persists, return to repair centre.

Source:Benutzerhandbuch - Felicity FLS48100SG2.pdf
C14Output loss.Défaut
Description

Output loss / no output detected.

Cause

Breaker open, blown fuse, or output path interrupted.

Correction recommandée

1. Please check whether the circuit breaker is closed; 2. Please check whether the fuse is normal; 3. Restart the unit. if the error persists, contact the repair center.

Source:HE-GF-FLA-48500 Manual_20250327_EN.pdf
C14Output loss.Défaut
Description

Output-loss fault displayed on the LCD BMS fault code / flag screen (section 4.4); the BMS detects no output current path / output cannot be enabled.

Cause

Open circuit breaker, blown internal fuse, or other open in the output path. Section 2.3 lists Built-in smart BMS, Fuse as the protection elements.

Correction recommandée

1. Please check whether the circuit breaker is closed. 2. Please check whether the fuse is normal. 3. Restart the unit, if the error persists, contact the repair center.

Source:358-010291-07.pdf · page 9
C14Output loss.Défaut
Cause

No output from the battery pack. Possible causes: circuit breaker open, or fuse blown.

Correction recommandée

1. Please check whether the circuit breaker is closed. 2. Please check whether the fuse is normal. 3. Restart the unit. if the error persists, contact the repair center.

Source:LUX-E-48100LG03-Lithium-Battery-User-Guide.pdf · page 13
C14C14Défaut
Correction recommandée

1. Please check whether the circuit breaker is closed. 2. Please check whether the fuse is normal. 3. Restart the unit. if the error persists, contact the repair center.

Source:LUX-E-48200LG03-Lithium-Battery-User-Guide.pdf · page 13
C14C14Défaut
Cause

Circuit breaker may be open or fuse may be blown.

Correction recommandée

1. Please check whether the circuit breaker is closed; 2. Please check whether the fuse is normal; 3. Restart the unit. if the error persists, contact the repair center.

Source:LUX-E-48230.250LG03-Lithium-Battery-User-Guide.pdf
C14Output loss.Critique
Description

Battery pack has lost its output (no DC output detected at the terminals).

Cause

Open circuit breaker, blown fuse or other output-path interruption.

Correction recommandée

1. Please check whether the circuit breaker is closed; 2. Please check whether the fuse is normal; 3. Restart the unit. if the error persists, contact the repair center.

Source:LUX-X-48100LG01-Litium-Battery-User-Guide.pdf · page 17
C14Output loss.Critique
Description

Battery pack has lost its output (no DC output detected at the terminals).

Cause

Open circuit breaker, blown fuse or other output-path interruption.

Correction recommandée

1. Please check whether the circuit breaker is closed; 2. Please check whether the fuse is normal; 3. Restart the unit, if the error persists, contact the repair center.

Source:358-S010024-03LUX-X-48100LG01-User-manual_compressed.pdf · page 23
C14Output loss.Défaut
Cause

No output from the battery pack. Possible causes: circuit breaker open, or fuse blown.

Correction recommandée

1. Please check whether the circuit breaker is closed. 2. Please check whether the fuse is normal. 3. Restart the unit. if the error persists, contact the repair center.

Source:LUX-Y-4828048300LG01-Lithium-Battery-User-Guide.pdf · page 8

Compilé à partir des manuels utilisateur officiels FelicityESS. Consultez toujours le manuel de votre appareil et un technicien qualifié avant toute réparation.