LUX-X-48100LG01-US
Batterie25 codesC01Battery overvoltage.Critique
Total battery pack voltage has exceeded the upper protection threshold.
Restart the unit, if the error persists, contact the repair center.
358-S010024-03LUX-X-48100LG01-User-manual_compressed.pdf · page 23C02Battery undervoltage.Critique
Total battery pack voltage has dropped below the lower protection threshold.
Restart the unit, if the error persists, contact the repair center.
358-S010024-03LUX-X-48100LG01-User-manual_compressed.pdf · page 23C03Cell overvoltage.Critique
An individual cell voltage has exceeded its upper protection threshold.
Restart the unit, if the error persists, contact the repair center.
358-S010024-03LUX-X-48100LG01-User-manual_compressed.pdf · page 23C04Cell undervoltage.Critique
An individual cell voltage has dropped below its lower protection threshold.
Restart the unit, if the error persists, contact the repair center.
358-S010024-03LUX-X-48100LG01-User-manual_compressed.pdf · page 23C05Charge overcurrent.Critique
Charging current has exceeded the protection limit.
Restart the unit, if the error persists, contact the repair center.
358-S010024-03LUX-X-48100LG01-User-manual_compressed.pdf · page 23C06Discharge overcurrent.Critique
Discharging current has exceeded the protection limit.
Restart the unit, if the error persists, contact the repair center.
358-S010024-03LUX-X-48100LG01-User-manual_compressed.pdf · page 23C07MOS overtemperature.Critique
MOSFET (power switch) temperature has exceeded the upper protection limit. Note: this code is listed twice in the manual's fault table.
1. The inner temperature is over the limitation. 2. Check whether the ambient temperature is too high.
Reduce ambient temperature and improve ventilation; if the error persists, return to repair center.
358-S010024-03LUX-X-48100LG01-User-manual_compressed.pdf · page 23C08MOS undertemperature.Critique
MOSFET (power switch) temperature is below the lower protection limit.
1. The internal temperature is lower than the limit range. 2. Check whether the ambient temperature is too low.
Raise ambient temperature above the operating minimum; if the error persists, return to repair center.
358-S010024-03LUX-X-48100LG01-User-manual_compressed.pdf · page 23C09Cell overtemperature.Critique
A battery cell temperature has exceeded the upper protection limit.
Restart the unit, if the error persists, contact the repair center.
358-S010024-03LUX-X-48100LG01-User-manual_compressed.pdf · page 23C10Cell undertemperature.Critique
A battery cell temperature has dropped below the lower protection limit.
Restart the unit, if the error persists, contact the repair center.
358-S010024-03LUX-X-48100LG01-User-manual_compressed.pdf · page 23C11Abnormal current sampling.Avertissement
Internal current sensor / sampling circuit returned an abnormal reading.
Restart the unit, if the error persists, contact the repair center.
358-S010024-03LUX-X-48100LG01-User-manual_compressed.pdf · page 23C12Abnormal output impedance.Avertissement
Detected abnormal output-side impedance (e.g. faulty contactor, bad connection or load anomaly).
Restart the unit, if the error persists, contact the repair center.
358-S010024-03LUX-X-48100LG01-User-manual_compressed.pdf · page 23C13Parallel failed.Avertissement
Parallel-mode handshake/operation between battery packs failed.
Either a single unit is wrongly configured for parallel operation, or wires are misconnected during parallel installation.
1. Please check if single unit is installed to parallel system. 2. if this error happens during parallel installation, please check wires connection. if they are connected correctly, please finish parallel installation first, and then restart the unit. 3. if the problem remains, please contact your installer.
358-S010024-03LUX-X-48100LG01-User-manual_compressed.pdf · page 23C14Output loss.Critique
Battery pack has lost its output (no DC output detected at the terminals).
Open circuit breaker, blown fuse or other output-path interruption.
1. Please check whether the circuit breaker is closed; 2. Please check whether the fuse is normal; 3. Restart the unit, if the error persists, contact the repair center.
358-S010024-03LUX-X-48100LG01-User-manual_compressed.pdf · page 23FAULT-LED-BMSTHBMS temperature high.Critique
FAULT mode signalled by RED LED ON with LED1 ON, LED2 ON, LED3 ON, LED4 OFF: BMS PCB / MOSFET temperature above safe limit.
Inner BMS temperature exceeds limitation; ambient too hot or excessive current.
Reduce ambient temperature, ensure clearance for heat dissipation, reduce current; allow to cool.
358-S010024-03LUX-X-48100LG01-User-manual_compressed.pdf · page 21FAULT-LED-BMSTLBMS temperature low.Critique
FAULT mode signalled by RED LED ON with LED1 OFF, LED2 OFF, LED3 OFF, LED4 ON: BMS PCB temperature below safe limit.
BMS internal temperature below operating range; ambient too cold.
Move battery to environment within operating temperature range (above 0 degC).
358-S010024-03LUX-X-48100LG01-User-manual_compressed.pdf · page 21FAULT-LED-BVHBattery voltage high.Critique
FAULT mode signalled by RED LED ON, GREEN LED OFF, with LED1 ON, LED2 OFF, LED3 OFF, LED4 OFF: total battery voltage above safe threshold.
Battery pack voltage above safe threshold.
Stop charging and check charger/inverter charge-voltage settings; allow voltage to recover.
358-S010024-03LUX-X-48100LG01-User-manual_compressed.pdf · page 21FAULT-LED-BVLBattery voltage low.Critique
FAULT mode signalled by RED LED ON with LED1 OFF, LED2 ON, LED3 OFF, LED4 OFF: total battery voltage below safe threshold.
Battery pack voltage below safe threshold (deeply discharged).
Recharge the battery promptly using AC or PV; do not leave the pack idle in low-power state.
358-S010024-03LUX-X-48100LG01-User-manual_compressed.pdf · page 21FAULT-LED-CCHCharging current high.Critique
FAULT mode signalled by RED LED ON with LED1 ON, LED2 OFF, LED3 ON, LED4 OFF: charging current above protection limit.
Charger / inverter requesting current above pack limit.
Reduce charge current setting on the inverter/charger to within the pack rating.
358-S010024-03LUX-X-48100LG01-User-manual_compressed.pdf · page 21FAULT-LED-CSACurrent sensor abnormal.Avertissement
FAULT mode signalled by RED LED ON with LED1 ON, LED2 ON, LED3 OFF, LED4 ON: internal current sensor reports abnormal reading.
Faulty current sampling circuit / sensor inside BMS.
Restart the unit; if the error persists, return to repair center.
358-S010024-03LUX-X-48100LG01-User-manual_compressed.pdf · page 21FAULT-LED-CTHCell temperature high.Critique
FAULT mode signalled by RED LED ON with LED1 ON, LED2 OFF, LED3 OFF, LED4 ON: a cell temperature is above safe limit.
Cell temperature exceeds protection threshold.
Stop charging/discharging, allow battery to cool; check ambient temperature and ventilation.
358-S010024-03LUX-X-48100LG01-User-manual_compressed.pdf · page 21FAULT-LED-CTLCell temperature low.Critique
FAULT mode signalled by RED LED ON with LED1 OFF, LED2 ON, LED3 OFF, LED4 ON: a cell temperature is below safe limit.
Cell temperature below operating range.
Warm the battery to above 0 degC before charging/discharging.
358-S010024-03LUX-X-48100LG01-User-manual_compressed.pdf · page 21FAULT-LED-CVHCell voltage high.Critique
FAULT mode signalled by RED LED ON with LED1 ON, LED2 ON, LED3 OFF, LED4 OFF: an individual cell voltage exceeds the safe upper limit.
One or more cells over-voltage; possible cell imbalance or charger overvoltage.
Stop charging; verify charger/inverter max charge voltage; allow BMS to balance and recover.
358-S010024-03LUX-X-48100LG01-User-manual_compressed.pdf · page 21FAULT-LED-CVLCell voltage low.Critique
FAULT mode signalled by RED LED ON with LED1 OFF, LED2 OFF, LED3 ON, LED4 OFF: an individual cell voltage is below the safe lower limit.
Cell undervoltage / over-discharge.
Recharge promptly; if cells fail to recover, return battery to repair center.
358-S010024-03LUX-X-48100LG01-User-manual_compressed.pdf · page 21FAULT-LED-DCHDischarging current high.Critique
FAULT mode signalled by RED LED ON with LED1 OFF, LED2 ON, LED3 ON, LED4 OFF: discharge current above protection limit.
Load / inverter draws current above pack limit; possible short circuit.
Reduce load; check for short-circuit on output; verify inverter sizing matches battery count.
358-S010024-03LUX-X-48100LG01-User-manual_compressed.pdf · page 21Compilé à partir des manuels utilisateur officiels FelicityESS. Consultez toujours le manuel de votre appareil et un technicien qualifié avant toute réparation.