LUX-X-48050LG01

Batterie27 codes
also coversLUX-X-48050LCG01LUX-X-48050LMG01LUX-X-48050LG01M2LUX-X-48050LG01M3LUX-X-48050LG01M4
27 Défaut
BATTERY VOLTAGE HIGHBATTERY VOLTAGE HIGHDéfaut
Description

Battery pack voltage above safe operating threshold (BMS protection flag).

Correction recommandée

BMS protection flag displayed on LCD information page. Restart unit; if persists, return to repair center.

Source:LUX-X-48050LG01-low-voltage-battery-user-guide.pdf · page 16
BATTERY VOLTAGE LOWBATTERY VOLTAGE LOWDéfaut
Description

Battery pack voltage below safe operating threshold (BMS protection flag).

Correction recommandée

BMS protection flag. Charge battery via mains or solar power as soon as possible to avoid over-discharge lockout.

Source:LUX-X-48050LG01-low-voltage-battery-user-guide.pdf · page 16
BMS TEMPERATURE HIGHBMS TEMPERATURE HIGHDéfaut
Description

BMS internal temperature above safe operating range.

Correction recommandée

BMS protection flag. Check ambient temperature, ensure ventilation, operate within 0-55 C charge / -20 to 55 C discharge.

Source:LUX-X-48050LG01-low-voltage-battery-user-guide.pdf · page 16
BMS TEMPERATURE LOWBMS TEMPERATURE LOWDéfaut
Description

BMS internal temperature below safe operating range.

Correction recommandée

BMS protection flag. Check ambient temperature is not too low.

Source:LUX-X-48050LG01-low-voltage-battery-user-guide.pdf · page 16
C01C01Défaut
Description

Battery overvoltage.

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:LUX-X-48050LG01-low-voltage-battery-user-guide.pdf · page 17
C02C02Défaut
Description

Battery undervoltage.

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:LUX-X-48050LG01-low-voltage-battery-user-guide.pdf · page 17
C03C03Défaut
Description

Cell overvoltage.

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:LUX-X-48050LG01-low-voltage-battery-user-guide.pdf · page 17
C04C04Défaut
Description

Cell undervoltage.

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:LUX-X-48050LG01-low-voltage-battery-user-guide.pdf · page 17
C05C05Défaut
Description

Charge overcurrent.

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:LUX-X-48050LG01-low-voltage-battery-user-guide.pdf · page 17
C06C06Défaut
Description

Discharge overcurrent.

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:LUX-X-48050LG01-low-voltage-battery-user-guide.pdf · page 17
C07C07Défaut
Description

MOS overtemperature.

Correction recommandée

1. The inner temperature is over the limitation. 2. Check whether the ambient temperature is too high.

Source:LUX-X-48050LG01-low-voltage-battery-user-guide.pdf · page 17
C08C08Défaut
Description

MOS undertemperature.

Correction recommandée

1. The internal temperature is lower than the limit range. 2. Check whether the ambient temperature is too low.

Source:LUX-X-48050LG01-low-voltage-battery-user-guide.pdf · page 17
C09C09Défaut
Description

Cell overtemperature.

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:LUX-X-48050LG01-low-voltage-battery-user-guide.pdf · page 17
C10C10Défaut
Description

Cell undertemperature.

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:LUX-X-48050LG01-low-voltage-battery-user-guide.pdf · page 17
C11C11Défaut
Description

Abnormal current sampling.

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:LUX-X-48050LG01-low-voltage-battery-user-guide.pdf · page 17
C12C12Défaut
Description

Abnormal output impedance.

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:LUX-X-48050LG01-low-voltage-battery-user-guide.pdf · page 17
CELL TEMPERATURE HIGHCELL TEMPERATURE HIGHDéfaut
Description

Battery cell temperature above safe operating range.

Correction recommandée

BMS protection flag. Check ambient temperature, ensure ventilation.

Source:LUX-X-48050LG01-low-voltage-battery-user-guide.pdf · page 16
CELL TEMPERATURE LOWCELL TEMPERATURE LOWDéfaut
Description

Battery cell temperature below safe operating range.

Correction recommandée

BMS protection flag. Check ambient temperature; do not charge below 0 C.

Source:LUX-X-48050LG01-low-voltage-battery-user-guide.pdf · page 16
CELL VOLTAGE HIGHCELL VOLTAGE HIGHDéfaut
Description

Individual cell voltage above safe limit (BMS protection flag).

Correction recommandée

BMS protection flag. Restart unit; if persists, return to repair center.

Source:LUX-X-48050LG01-low-voltage-battery-user-guide.pdf · page 16
CELL VOLTAGE LOWCELL VOLTAGE LOWDéfaut
Description

Individual cell voltage below safe limit (BMS protection flag).

Correction recommandée

BMS protection flag. Charge battery as soon as possible.

Source:LUX-X-48050LG01-low-voltage-battery-user-guide.pdf · page 16
CHARGING CURRENT HIGHCHARGING CURRENT HIGHDéfaut
Description

Charging current exceeds maximum allowable value (BMS protection flag).

Correction recommandée

BMS protection flag. Verify charge current within rated limits (Recommend 25A/40A; Max continuous 50A/80A; Peak 100A/200A/300A).

Source:LUX-X-48050LG01-low-voltage-battery-user-guide.pdf · page 16
CURRENT SENSOR ABNORMALCURRENT SENSOR ABNORMALDéfaut
Description

Current sensor reading is abnormal / sampling failure.

Correction recommandée

BMS protection flag. Restart unit; if persists, return to repair center.

Source:LUX-X-48050LG01-low-voltage-battery-user-guide.pdf · page 16
DISCHARGING CURRENT HIGHDISCHARGING CURRENT HIGHDéfaut
Description

Discharging current exceeds maximum allowable value (BMS protection flag).

Correction recommandée

BMS protection flag. Verify load current within rated limits.

Source:LUX-X-48050LG01-low-voltage-battery-user-guide.pdf · page 16
LOW POWERLOW POWERDéfaut
Description

Battery in low-power state, output disabled (SOC LEDs OFF).

Correction recommandée

Charge the battery as soon as possible when main power or solar energy is available. Note: Over-discharged pack may not be reactivated by AC/PV cable and may require special charging activation.

Source:LUX-X-48050LG01-low-voltage-battery-user-guide.pdf · page 15
Output lossOutput lossDéfaut
Description

Output power loss / no output.

Correction recommandée

1. Please check whether the circuit breaker is closed; 2. Please check whether the fuse is normal; 3. Restart the unit, if the error persists, contact the repair center.

Source:LUX-X-48050LG01-low-voltage-battery-user-guide.pdf · page 17
Parallel failedParallel failedDéfaut
Description

Parallel connection failure between battery units.

Correction recommandée

1. Please check if single unit is installed to parallel system. 2. if this error happens during parallel installation, please check wires connection. if they are connected correctly, please finish parallel installation first, and then restart the unit. 3. if the problem remains, please contact your installer.

Source:LUX-X-48050LG01-low-voltage-battery-user-guide.pdf · page 17
SOC < 10%SOC < 10%Défaut
Description

Low state of charge warning - LED1 flashing (default).

Correction recommandée

Charge the battery as soon as possible. The battery should be fully charged at least once per month for accurate SOC calculation.

Source:LUX-X-48050LG01-low-voltage-battery-user-guide.pdf · page 15

Compilé à partir des manuels utilisateur officiels FelicityESS. Consultez toujours le manuel de votre appareil et un technicien qualifié avant toute réparation.