LPBF48200-H
Batterie13 codesC01Battery overvoltage.Défaut
Battery pack overall voltage above protection threshold (BMS protection).
Total battery voltage has exceeded the BMS upper voltage limit.
Restart the unit; if the error persists, contact the repair center.
Manual-LPBF48200-H.pdf · page 10C02Battery undervoltage.Défaut
Battery pack overall voltage below protection threshold (BMS protection).
Total battery voltage has fallen below the BMS lower voltage limit (over-discharge).
Restart the unit; if the error persists, contact the repair center.
Manual-LPBF48200-H.pdf · page 10C03Single cell overvoltage.Défaut
An individual cell voltage has exceeded the protection limit.
One cell voltage above safe upper threshold (cell imbalance or overcharge).
Restart the unit; if the error persists, contact the repair center.
Manual-LPBF48200-H.pdf · page 10C04Single cell undervoltage.Défaut
An individual cell voltage has dropped below the protection limit.
One cell voltage below safe lower threshold (cell imbalance or over-discharge).
Restart the unit; if the error persists, contact the repair center.
Manual-LPBF48200-H.pdf · page 10C05Battery charge overcurrent.Défaut
Charging current has exceeded the BMS protection limit.
Charging current above the maximum charge current rating (>120A on LPBF48200-H).
Restart the unit; if the error persists, contact the repair center.
Manual-LPBF48200-H.pdf · page 10C06Battery discharge overcurrent.Défaut
Discharge current has exceeded the BMS protection limit.
Discharge current above the maximum discharge rating (>120A on LPBF48200-H).
Restart the unit; if the error persists, contact the repair center.
Manual-LPBF48200-H.pdf · page 10C07MOS tube overtemperature.Défaut
MOSFET (power switch) temperature is above the operating limit.
Internal temperature is over the limitation; ambient temperature may be too high.
1. The inner temperature is over the limitation. 2. Check whether the ambient temperature is too high.
Manual-LPBF48200-H.pdf · page 10C08MOS tube undertemperature.Défaut
MOSFET (power switch) temperature is below the operating limit.
Internal temperature is lower than the limit range; ambient temperature may be too low.
1. The internal temperature is lower than the limit range. 2. Check whether the ambient temperature is too low.
Manual-LPBF48200-H.pdf · page 10C09Single cell overtemperature.Défaut
An individual cell temperature has exceeded the operating limit.
Cell temperature above safe upper threshold (likely high ambient temperature or excessive current).
Restart the unit; if the error persists, contact the repair center.
Manual-LPBF48200-H.pdf · page 10C10Single cell undertemperature.Défaut
An individual cell temperature is below the operating limit.
Cell temperature below safe lower threshold (likely cold ambient, charging blocked below 0 deg C).
Restart the unit; if the error persists, contact the repair center.
Manual-LPBF48200-H.pdf · page 10C11Abnormal current sampling.Défaut
BMS internal current measurement circuit fault.
Current sensor / sampling circuit malfunction (internal hardware fault).
Restart the unit; if the error persists, contact the repair center.
Manual-LPBF48200-H.pdf · page 10C12Abnormal output impedance.Défaut
Output impedance is outside expected range.
Loose terminal connection, internal MOS/wiring fault, or external short/open condition affecting impedance.
Restart the unit; if the error persists, contact the repair center.
Manual-LPBF48200-H.pdf · page 10C13Parallel failed.Défaut
Battery pack could not satisfy parallel-operation conditions (e.g. voltage difference between local and other packs >3V, or wiring issue).
Single unit configured as parallel slave, mis-wired parallel connection, or voltage mismatch (>3V) between paralleled packs.
1. Please check if single unit is installed to parallel system. 2. if this error happens during parallel installation, please check wires connection. if they are connected correctly, please finish parallel installation first, and then restart the unit. 3. if the problem remains, please contact your installer.
Manual-LPBF48200-H.pdf · page 10Compilé à partir des manuels utilisateur officiels FelicityESS. Consultez toujours le manuel de votre appareil et un technicien qualifié avant toute réparation.