LPBF48200-H

Batterie13 codes
also coversLPBF48100-H
13 Défaut
C01Battery overvoltage.Défaut
Description

Battery pack overall voltage above protection threshold (BMS protection).

Cause

Total battery voltage has exceeded the BMS upper voltage limit.

Correction recommandée

Restart the unit; if the error persists, contact the repair center.

Source:Manual-LPBF48200-H.pdf · page 10
C02Battery undervoltage.Défaut
Description

Battery pack overall voltage below protection threshold (BMS protection).

Cause

Total battery voltage has fallen below the BMS lower voltage limit (over-discharge).

Correction recommandée

Restart the unit; if the error persists, contact the repair center.

Source:Manual-LPBF48200-H.pdf · page 10
C03Single cell overvoltage.Défaut
Description

An individual cell voltage has exceeded the protection limit.

Cause

One cell voltage above safe upper threshold (cell imbalance or overcharge).

Correction recommandée

Restart the unit; if the error persists, contact the repair center.

Source:Manual-LPBF48200-H.pdf · page 10
C04Single cell undervoltage.Défaut
Description

An individual cell voltage has dropped below the protection limit.

Cause

One cell voltage below safe lower threshold (cell imbalance or over-discharge).

Correction recommandée

Restart the unit; if the error persists, contact the repair center.

Source:Manual-LPBF48200-H.pdf · page 10
C05Battery charge overcurrent.Défaut
Description

Charging current has exceeded the BMS protection limit.

Cause

Charging current above the maximum charge current rating (>120A on LPBF48200-H).

Correction recommandée

Restart the unit; if the error persists, contact the repair center.

Source:Manual-LPBF48200-H.pdf · page 10
C06Battery discharge overcurrent.Défaut
Description

Discharge current has exceeded the BMS protection limit.

Cause

Discharge current above the maximum discharge rating (>120A on LPBF48200-H).

Correction recommandée

Restart the unit; if the error persists, contact the repair center.

Source:Manual-LPBF48200-H.pdf · page 10
C07MOS tube overtemperature.Défaut
Description

MOSFET (power switch) temperature is above the operating limit.

Cause

Internal temperature is over the limitation; ambient temperature may be too high.

Correction recommandée

1. The inner temperature is over the limitation. 2. Check whether the ambient temperature is too high.

Source:Manual-LPBF48200-H.pdf · page 10
C08MOS tube undertemperature.Défaut
Description

MOSFET (power switch) temperature is below the operating limit.

Cause

Internal temperature is lower than the limit range; ambient temperature may be too low.

Correction recommandée

1. The internal temperature is lower than the limit range. 2. Check whether the ambient temperature is too low.

Source:Manual-LPBF48200-H.pdf · page 10
C09Single cell overtemperature.Défaut
Description

An individual cell temperature has exceeded the operating limit.

Cause

Cell temperature above safe upper threshold (likely high ambient temperature or excessive current).

Correction recommandée

Restart the unit; if the error persists, contact the repair center.

Source:Manual-LPBF48200-H.pdf · page 10
C10Single cell undertemperature.Défaut
Description

An individual cell temperature is below the operating limit.

Cause

Cell temperature below safe lower threshold (likely cold ambient, charging blocked below 0 deg C).

Correction recommandée

Restart the unit; if the error persists, contact the repair center.

Source:Manual-LPBF48200-H.pdf · page 10
C11Abnormal current sampling.Défaut
Description

BMS internal current measurement circuit fault.

Cause

Current sensor / sampling circuit malfunction (internal hardware fault).

Correction recommandée

Restart the unit; if the error persists, contact the repair center.

Source:Manual-LPBF48200-H.pdf · page 10
C12Abnormal output impedance.Défaut
Description

Output impedance is outside expected range.

Cause

Loose terminal connection, internal MOS/wiring fault, or external short/open condition affecting impedance.

Correction recommandée

Restart the unit; if the error persists, contact the repair center.

Source:Manual-LPBF48200-H.pdf · page 10
C13Parallel failed.Défaut
Description

Battery pack could not satisfy parallel-operation conditions (e.g. voltage difference between local and other packs >3V, or wiring issue).

Cause

Single unit configured as parallel slave, mis-wired parallel connection, or voltage mismatch (>3V) between paralleled packs.

Correction recommandée

1. Please check if single unit is installed to parallel system. 2. if this error happens during parallel installation, please check wires connection. if they are connected correctly, please finish parallel installation first, and then restart the unit. 3. if the problem remains, please contact your installer.

Source:Manual-LPBF48200-H.pdf · page 10

Compilé à partir des manuels utilisateur officiels FelicityESS. Consultez toujours le manuel de votre appareil et un technicien qualifié avant toute réparation.