Felicity Solar T-REX-40KHP3G01

InvertersModel T-REX-40KHP3G01

Felicity Solar T-REX-40KHP3G01 40kW Three-Phase Hybrid Solar Inverter

A 40 kW three-phase hybrid inverter that accepts 52 kW of PV across four MPPT trackers at 36+36+36+36 A, backs up 40 kW, and guards a 63.8 A output behind 192 A of overcurrent protection.

  • Rated Output Power: 40 kW
  • Max Efficiency: 97.6 %
  • Max PV Input Power: 52 kW
  • Battery Voltage Range: 160-800 V

Models in the T-REX-10KHP3G01 – T-REX-50KHP3G01 family

What sets the T-REX-40KHP3G01 apart from the other 5 models in the family: AC Output Line Voltage 380-400 V; AC Output Voltage 220-230 V; AC Rated Output Current 58 A; AC Wiring Mode 3L+N+PE; Backup Rated Output Power 40 kW; Battery Inputs 2; Battery Type LFP; Battery Voltage Range 160-800 V.

AED 13,750incl. VAT

In stock

  • Delivered within 3 business days, door to door, to every market we serve.
  • Dispatched the same business day for an order placed before 21:00 (Dubai time), or the next business day after.
  • Delivery charge: free
  • 2-year warranty

Felicity Solar T-REX-40KHP3G01 40kW Three-Phase Hybrid Solar Inverter features

  • 52 kW of PV into a 40 kW inverter

    Maximum PV input power is 52 kW on a 40 kW rated inverter, spread over four MPPT trackers that each accept 36 A for 36+36+36+36 A of PV input current, up to a 1000 V maximum PV voltage.

  • Four MPPTs tracking 200-850 V from a 250 V start-up

    The four MPPT trackers open at a 250 V start-up voltage and run from 200 to 850 V around a 600 V rated PV input, from a 150 V minimum DC input voltage, at 99.9% MPPT efficiency.

  • 44 kW maximum AC output at 63.8 A

    Rated output is 40 kW and 40 kVA, peaking at 44 kW and 63.8 A on three-phase 220-230 V 3L+N+PE wiring at 50/60 Hz, with 1.5 times rated power for 10 s of surge and under 3% total harmonic distortion.

  • 40 kW of backup on a 160-800 V LFP bank

    Backup rated power is 40 kW, drawn from two battery inputs carrying an LFP bank across 160-800 V at 50+50 A of maximum charging and 50+50 A of maximum discharging current, with BMS communication over RS485 and CAN.

  • 192 A output overcurrent protection, 10 ms transfer

    Output overcurrent protection is rated 192 A and backup takes over in 10 ms, behind anti-islanding protection, a residual current monitoring unit, insulation resistor detection, PV and battery reverse polarity protection and surge protection level II.

  • 85.6 kg IP65 chassis, 12 units in parallel

    The wall-mounted IP65 chassis weighs 85.6 kg net and 102.3 kg gross, works from -25 to 60 °C with derating above 50 °C and up to 3000 m with derating above 2000 m, and parallels up to 12 units. Supplied with a 2 Years warranty.

About the Felicity Solar T-REX-40KHP3G01 40kW Three-Phase Hybrid Solar Inverter

The Felicity Solar T-REX-40KHP3G01 is a three-phase hybrid solar inverter rated 40 kW and 40 kVA, accepting up to 52 kW of PV across four MPPT trackers, delivering 44 kW of maximum AC output and 40 kW of backup power, with a maximum output current of 63.8 A at 97.6% peak efficiency. Each tracker takes 36 A, tracks from 200 to 850 V after a 250 V start-up around a 600 V rated PV input, and works from a 150 V minimum DC input up to 1000 V. Two battery inputs carry an LFP bank across 160-800 V at 50+50 A of charge and discharge, talking to the BMS over RS485 and CAN. Output is 220-230 V per phase on 3L+N+PE wiring at 50/60 Hz, under 3% THD, with a 10 ms transfer time and 1.5 times rated power for 10 s. European efficiency is 97% and MPPT efficiency 99.9%. The wall-mounted IP65 chassis weighs 85.6 kg net, runs from -25 to 60 °C and parallels up to 12 units. We are an authorised Felicity Solar distributor and supply it with a 2 Years warranty.

Specifications last updated 23 July 2026

Felicity Solar T-REX-40KHP3G01 40kW Three-Phase Hybrid Solar Inverter full specifications

Electrical(51)

AC Output Line Voltage380-400 V
AC Output Voltage220-230 V
AC Rated Output Current58 A
AC Wiring Mode3L+N+PE
Backup Rated Output Power40 kW
Battery Inputs2
Battery TypeLFP
Battery Voltage Range160-800 V
Charge AlgorithmSelf-Adaption to BMS
European Efficiency97 %
Grid Frequency Range (50 Hz)45-55 Hz
Grid Frequency Range (60 Hz)55-65 Hz
Grid RegulationNTS & UNE217001 & UNE217002, CEI 0-21, NRS 097-2-1, NC RFG (Poland), VDE 4105, G99, EN 50549-1, EN 50549-1+Netherlands
Ground Fault Current MonitoringYes
Input Voltage Range184-264.5 V
MPPT Efficiency99.9 %
MPPT Full-Load Voltage Range360-850 V
MPPT Trackers4
MPPT Voltage Range200-850 V
Max AC Output Power44 kW
Max AC Pass-Through Current200 A
Max Charging Current50+50 A
Max Discharging Current50+50 A
Max Efficiency97.6 %
Max Output Current63.8 A
Max Output Overcurrent Protection192 A
Max PV Input Current36+36+36+36 A
Max PV Input Power52 kW
Max PV Voltage1000 V
Max Short-Circuit Current55+55+55+55 A
Min DC Input Voltage150 V
Nominal AC Input Line Voltage380-400 V
Nominal AC Input Voltage220-230 V
Nominal Input Frequency50/60 Hz
Output Frequency50/60 Hz
Output Short-Circuit ProtectionYes
Overload ProtectionYes
Overvoltage Category (AC)III
Overvoltage Category (DC)II
PhaseThree Phase
Power Factor Adjustment Range0.8 leading to 0.8 lagging
ProtectionPV Input Lightning Protection, PV String Input Reverse Polarity Protection, Battery Input Lightning Protection, AC Output Lightning Protection, Battery Input Reverse Polarity Protection, Insulation Resistor Detection, Residual Current Monitoring Unit, Output Over Current Protection, Output Short-Circuit Protection, Output Over Voltage Protection, Anti-islanding Protection
Rated Apparent Output Power40 kVA
Rated Output Power40 kW
Rated PV Input Voltage600 V
Start-Up Voltage250 V
Strings per MPPT2
Surge Protection Level (AC)II
Surge Rating1.5*rated (10s)
Total Harmonic Distortion<3 %
Transfer Time10 ms

Mechanical(11)

BMS CommunicationRS485, CAN
Communication InterfaceRS232, RS485
DisplayLCD Touch Screen
Gross Weight102.3 kg
Installation StyleWall-Mounted
Monitoring ModuleWiFi/GPRS
Net Weight85.6 kg
Package Dimensions1114 x 774 x 469 mm
Parallel Capability12
Safety StandardEN 62477-1, IEC 62109-1, IEC 62109-2
TopologyNon-Isolated

Environmental(5)

CoolingSmart Cooling
IP RatingIP65
Operating Altitude3000 (>2000 derating) m
Operating Temperature Range-25 to 60 (>50 derating) °C
Relative Humidity0-95 (non-condensing) %

Certifications(3)

  • EN 62477-1
  • IEC 62109-1
  • IEC 62109-2

Downloads & support

Frequently Asked Questions

How much solar can the T-REX-40KHP3G01 take?

52 kW is the maximum PV input power, spread over four MPPT trackers that take 36+36+36+36 A of PV input current. Tracking runs from 200 to 850 V after a 250 V start-up voltage, around a 600 V rated PV input, from a 150 V minimum DC input voltage up to a 1000 V maximum PV voltage, at 99.9% MPPT efficiency.

What does the T-REX-40KHP3G01 deliver on the AC side?

40 kW rated output power and 40 kVA of apparent power, rising to 44 kW of maximum AC output at 63.8 A of maximum output current, three-phase at 220-230 V on 3L+N+PE wiring. It runs at 50/60 Hz from a 184-264.5 V input range, holds total harmonic distortion under 3%, adjusts power factor from 0.8 leading to 0.8 lagging, surges to 1.5 times rated power for 10 s and peaks at 97.6% efficiency, with 97% European efficiency. Grid settings cover NTS, UNE217001, UNE217002, CEI 0-21, NRS 097-2-1, NC RFG (Poland), VDE 4105, G99 and EN 50549-1.

What battery does the T-REX-40KHP3G01 work with?

160-800 V is the battery voltage range, carried on two battery inputs for LFP batteries at 50+50 A of maximum charging current and 50+50 A of maximum discharging current, backing up 40 kW. BMS communication runs over RS485 and CAN, the unit itself is reached over RS232 and RS485, and an LCD touch screen plus a WiFi or GPRS monitoring module report the bank. Transfer to backup takes 10 ms.

Where can the T-REX-40KHP3G01 be installed?

IP65 is the enclosure rating, so the wall-mounted chassis works outdoors from -25 to 60 °C with derating above 50 °C, in 0-95% non-condensing humidity and up to 3000 m of altitude with derating above 2000 m, under smart cooling. It weighs 85.6 kg net and 102.3 kg gross and ships in a 1114 x 774 x 469 mm package. The non-isolated unit carries overvoltage category III, surge protection level II, ground fault current monitoring and certification to EN 62477-1, IEC 62109-1 and IEC 62109-2, and up to 12 units can be paralleled. We are an authorised Felicity Solar distributor and supply it with a 2 Years warranty.

Customer reviews