One 180-580 V high-voltage battery input
The T-REX-10KHP3G01 carries a single battery input covering 180-580 V, taking Lead-Acid and Li-Ion banks over RS485 and CAN BMS communication.

InvertersModel T-REX-10KHP3G01
A three-phase hybrid inverter rated 10 kW, built around a single 180-580 V high-voltage battery input, 25 A of charge and discharge current, and 13 kW of recommended PV power on two MPPT trackers.
What sets the T-REX-10KHP3G01 apart from the other 5 models in the family: AC Output Line Voltage 400 V; AC Output Voltage 230 V; AC Rated Output Current 14.5 A; AC Wiring Mode 3L+N+PE; Backup Rated Output Power 10 kW; Battery Inputs 1; Battery Type Lead-Acid, Li-Ion; Battery Voltage Range 180-580 V.
In stock
The T-REX-10KHP3G01 carries a single battery input covering 180-580 V, taking Lead-Acid and Li-Ion banks over RS485 and CAN BMS communication.
Maximum charging current and maximum discharging current are both 25 A, AC charging is also 25 A, and maximum charge and discharge power is 10 kW.
Two MPPT trackers accept 15+15 A of PV input current from a 160 V start-up across a 200-850 V window, up to a 900 V maximum PV voltage and a 720 V nominal input.
Backup rated power is 10 kW at up to 30 A, three-phase on 3L+N+PE wiring at 230 V, with a 20 ms transfer time and THD held below 3%.
Maximum efficiency is 97.6%, European efficiency 97% and MPPT efficiency 99.9%, with a power factor above 0.99 adjustable from 0.8 leading to 0.8 lagging.
The wall-mounted IP65 chassis is naturally cooled, weighs 35.3 kg net and 39.7 kg gross, runs from -25 to 60 °C with derating above 45 °C, and parallels up to 10 units.
The Felicity Solar T-REX-10KHP3G01 is a 10 kW three-phase hybrid solar inverter built around a single 180-580 V high-voltage battery input. It charges and discharges that bank at up to 25 A for 10 kW of charge and discharge power, tracks solar on two MPPTs across 200-850 V, and converts at up to 97.6% maximum efficiency. Array sizing runs to 13 kW of recommended PV power at 15+15 A of input current, capped by a 900 V maximum PV voltage, from a 720 V nominal PV input and a 160 V start-up. On the grid side the T-REX-10KHP3G01 wires 3L+N+PE at 230 V per phase, accepts 184-264.5 V at up to 30 A, delivers up to 18 A, and hands over to a 10 kW backup circuit rated 30 A in 20 ms. The wall-mounted IP65 chassis is naturally cooled, weighs 35.3 kg net and 39.7 kg gross, ships in a 635 x 533 x 315 mm package and parallels up to 10 units. Certified to IEC 62109-1, IEC 62109-2 and IEC 62040-1. We are an authorised Felicity Solar distributor and supply it with a 2 Years warranty.
Specifications last updated 23 July 2026
| AC Output Line Voltage | 400 V |
|---|---|
| AC Output Voltage | 230 V |
| AC Rated Output Current | 14.5 A |
| AC Wiring Mode | 3L+N+PE |
| Backup Max Output Current | 30 A |
| Backup Rated Output Power | 10 kW |
| Battery Inputs | 1 |
| Battery Type | Lead-Acid, Li-Ion |
| Battery Voltage Range | 180-580 V |
| Charge Algorithm | Self-Adaption to BMS |
| European Efficiency | 97 % |
| Grid Frequency Range (50 Hz) | 45-55 Hz |
| Grid Frequency Range (60 Hz) | 55-65 Hz |
| Grid Regulation | VDE-AR-N 4105, G99/1, EN50549-1, CEI 0-21, AS 4777.2, NRS 097-2-1 |
| Ground Fault Current Monitoring | Yes |
| Input Voltage Range | 184-264.5 V |
| MPPT Efficiency | 99.9 % |
| MPPT Full-Load Voltage Range | 450-850 V |
| MPPT Trackers | 2 |
| MPPT Voltage Range | 200-850 V |
| Max AC Charge Current | 25 A |
| Max AC Input Current | 30 A |
| Max AC Output Power | 10 kW |
| Max AC Pass-Through Current | 30 A |
| Max Charge/Discharge Power | 10 kW |
| Max Charging Current | 25 A |
| Max Discharging Current | 25 A |
| Max Efficiency | 97.6 % |
|---|---|
| Max Output Current | 18 A |
| Max PV Input Current | 15+15 A |
| Max PV Voltage | 900 V |
| Max Recommended PV Power | 13 kW |
| Max Short-Circuit Current | 18+18 A |
| Nominal AC Input Line Voltage | 400 V |
| Nominal AC Input Voltage | 230 V |
| Nominal Input Frequency | 50/60 Hz |
| Output Frequency | 50/60 Hz |
| Output Short-Circuit Protection | Yes |
| Overload Protection | Yes |
| Overvoltage Category (AC) | III |
| Overvoltage Category (DC) | II |
| PV Working Voltage Range | 160-900 V |
| Phase | Three Phase |
| Power Factor | >0.99 |
| Power Factor Adjustment Range | 0.8 leading to 0.8 lagging |
| Protection | Output Over Current Protection, Output Over Power Protection, Output Shorted Protection, Anti-islanding Protection, GFCI Protection, Insulation Resistor Detection |
| Rated Apparent Output Power | 10 kVA |
| Rated Output Power | 10 kW |
| Rated PV Input Voltage | 720 V |
| Start-Up Voltage | 160 V |
| Strings per MPPT | 1 |
| Total Harmonic Distortion | <3 % |
| Transfer Time | 20 ms |
| BMS Communication | RS485, CAN |
|---|---|
| Communication Interface | RS232, RS485 |
| Display | LCD, LED |
| Gross Weight | 39.7 kg |
| Installation Style | Wall-Mounted |
| Monitoring Module | WiFi/GPRS |
| Net Weight | 35.3 kg |
|---|---|
| Package Dimensions | 635 x 533 x 315 mm |
| Parallel Capability | 10 |
| Safety Standard | IEC 62109-1, IEC 62109-2, IEC 62040-1 |
| Topology | Non-Isolated |
| Cooling | Nature |
|---|---|
| IP Rating | IP65 |
| Operating Altitude | 2000 m |
| Operating Temperature Range | -25 to 60 (>45 derating) °C |
| Relative Humidity | 0-100 % |
Looking up an error code on this FelicityESS T-REX-10KHP3G01? Browse the full list of codes for this device, with the cause and recommended fix for each.
View error codes for this device →180-580 V. The T-REX-10KHP3G01 has one battery input covering that high-voltage window and takes Lead-Acid and Li-Ion banks, with RS485 and CAN for BMS communication. Maximum charging current and maximum discharging current are both 25 A, AC charging is also 25 A, and maximum charge and discharge power is 10 kW.
13 kW is the maximum recommended PV power. Two MPPT trackers accept 15+15 A of PV input current from a 160 V start-up voltage across a 200-850 V tracking window, with a 720 V nominal PV input and a 900 V maximum PV voltage. MPPT efficiency is 99.9%, maximum efficiency 97.6% and European efficiency 97%.
20 ms is the transfer time. Backup rated power is 10 kW at up to 30 A, three-phase at 230 V on 3L+N+PE wiring, with THD below 3%, a power factor above 0.99, output over-current, over-power and short-circuit protection, anti-islanding protection, GFCI protection, insulation resistor detection and ground fault current monitoring.
35.3 kg net and 39.7 kg gross, shipping in a 635 x 533 x 315 mm package. The non-isolated chassis is wall-mounted, IP65-rated and naturally cooled, works from -25 to 60 °C with derating above 45 °C, in 0-100% relative humidity up to 2000 m of altitude, and carries an LCD and LED display with RS232 and RS485 interfaces. Up to 10 units can be paralleled.