Felicity Solar FLA12300PG2 3.75kWh Battery
A 3.75 kWh block whose continuous and maximum charge and discharge power are the same 1875 W, ending its discharge at a 12 V cut-off under an LED readout.
- Energy: 3.75kWh RUN LED: Indicates normal battery operating status(remains on during Dallery
- Operating Voltage: 11.2-14,4V Series Mode Warnings
In stock
Felicity Solar FLA12300PG2 3.75kWh Battery features
About the Felicity Solar FLA12300PG2 3.75kWh Battery
The Felicity Solar FLA12300PG2 is a 3.75 kWh battery block rated at 1875 W of charge and discharge power, quoted both as the continuous figure and as the maximum, so the rate it runs at all day is also its ceiling. Discharge ends at a 12 V cut-off, and an LED display reports the state of the pack. That single power figure makes the FLA12300PG2 straightforward to size against an inverter: there is no lower continuous allowance hiding behind a higher short-term peak, which is the usual trap when a battery quotes two numbers for the same job. The 3.75 kWh of nominal energy sits behind that same 1875 W rating, so the design question is one calculation rather than two. The LED indicator keeps commissioning simple, with no app or dongle needed to read the block during installation, and the 12 V cut-off gives the installer a single, plainly stated floor for the discharge. The FLA12300PG2 is covered by a 5 Years warranty. We are an authorised Felicity Solar distributor and supply the FLA12300PG2 from our own stock.
Specifications last updated 17 August 2026
Felicity Solar FLA12300PG2 3.75kWh Battery full specifications
Electrical
| Energy | 3.75kWh RUN LED: Indicates normal battery operating status(remains on during Dallery |
|---|---|
| Operating Voltage | 11.2-14,4V Series Mode Warnings |
| Communication | Used for |
| Max.Charge/Discharge Power | 1875W |
| Protection Level | IP21 Paralel Warnings Mode Diagram |
| Cycle Life | 26,000 Cycles Shown in 3,4 Connection for Parallel Mode User manual User manual |
| Protection | 4. OPERATION Main Circuit |
| RS485 cable | Battery |
| Max. Charging Voltage | 14.4V Trigger-GND C02 |
| Floating Charging Voltage | 14,4V Battery undervoltage 1. Assemble battery ring |
| Max. Charging Current | 150A |
| Cut-off Voltage | 12V |
| RS485 | C04 Cell undervoltage COO |
Mechanical
| Display | LED |
|---|---|
| Gross Weight | C05 |
| Product Dimension | 379x241x286mm |
| Package Dimension | 438x300x344mm |
Related Products

Felicity Solar FLA12300 12.8V 3.75kWh LiFePO4 Battery
- Nominal Energy:3.75 kWh
- Nominal Capacity:300 Ah

Felicity Solar LPBF12300 12.8V 3.75kWh LiFePO4 Battery
- Nominal Energy:3.75 kWh
- Nominal Capacity:300 Ah

Felicity Solar FLA12280-EU 12.8V 3.6kWh Battery
- Energy:3.6kWh LiFePO4: Higher safe performance and longer
- Nominal Voltage:12.8V

Felicity Solar FLA24200 25.6V 5kWh LiFePO4 Battery
- Nominal Energy:5 kWh
- Nominal Capacity:200 Ah

Felicity Solar FLA24200WG2 25.6V 5kWh LiFePO4 Battery
- Depth of Discharge (DOD):β₯95%
- Cycle Life:β₯6,000 Cycles

Felicity Solar LPBF24200-M 25.6V 5kWh LiFePO4 Battery
- Battery Type:LiFePO4
- Nominal Energy:5kWh

Felicity Solar LPBF48100-M 51.2V 5kWh LiFePO4 Battery
- Nominal Energy:5kWh
- Nominal Voltage:51.2V

Felicity Solar FLA48100 51.2V 5.12kWh LiFePO4 Battery
- Nominal Energy:5.12 kWh
- Nominal Capacity:100 Ah
Related Articles
How to Run a Whole House on Solar in Khartoum
An off-grid house is sized by surge, battery energy and charge current - and the surge row is the one that starts your fridge and your pump. Here are the published figures across the Felicity inverters and batteries, with the arithmetic to use them.
Read: How to Run a Whole House on Solar in Khartoum βHow to Maintain Solar Batteries for Maximum Lifespan
Extend your off-grid battery life with proper maintenance. Covers LiFePO4, gel, and lead-acid battery care, temperature management, and charge settings.
Read: How to Maintain Solar Batteries for Maximum Lifespan βHow to Protect Your Off-Grid Batteries from Overcharging
Overcharging destroys batteries fast. Learn how to set correct charge voltages, use temperature compensation, and configure your Felicity IVPS to prevent damage.
Read: How to Protect Your Off-Grid Batteries from Overcharging β