What it means
Reverse Polarity protection — Listed under 7.1 Battery System Features as part of the inverter-interface protection set: protects against reverse polarity connection of the inverter cables.
Cause: The inverter cables were connected with positive and negative swapped; reverse-polarity protection blocked the connection to prevent damage to the BMS and cells.
How to fix it
- Power down the inverter, wait 5 minutes for capacitors to discharge, then restart.
- If the fault recurs immediately or repeatedly, record the exact code and contact your installer or the manufacturer's service line.
Source: felicity-5.1-kwh-user-manual.pdf, p.4