What it means
Battery Over Temperature protection — Listed under 7.1 Battery System Features 'Battery Protection': protects against over-temperature at the battery side (working temp -10 to +50 C per spec).
Cause: Inverter internal temperature has exceeded the safe operating threshold. Causes include high ambient temperature, blocked cooling vents, failed cooling fan, or installation in direct sunlight.
How to fix it
- Power down the inverter and let it cool.
- Inspect cooling vents and fan inlets for dust, leaves, or insect nests — clean with compressed air.
- Confirm the inverter is installed in a shaded, ventilated location with the manufacturer's required clearances on all sides.
- If the fan does not spin on restart, fan replacement is required.
Source: felicity-5.1-kwh-user-manual.pdf, p.4