1000 Ah nominal capacity
Rated at the 10-hour rate to 1.8 V per cell at 25 °C.

Solar Battery and Lithium Battery StorageModel OPZV-1000AH-2V
One 2 V tubular-plate gel cell holding 1000 Ah — 2 kWh in a 77 kg block, with 0.45 mΩ internal resistance and up to 200 A of charge current.
In stock
Rated at the 10-hour rate to 1.8 V per cell at 25 °C.
One cell per unit at 2 V nominal voltage.
Maximum discharge current reaches 3800 A.
Float 2.25-2.3 V, maximum charging voltage 2.4 V, cycle service 2.37-2.4 V.
A.B.S. (UL94-HB) container, UL94-V0 optional, thread insert & bolt (F10-M8) terminals.
Charging 0-50 °C, storage -20 to 60 °C, self-discharge under 2% per month.
The Felicity Solar FL-OPzV-1000AH-2V is a single-cell 2 V OPzV battery rated 1000 Ah, or 2 kWh, at the 10-hour rate to 1.8 V per cell at 25 °C. Its internal resistance is 0.45 mΩ, it accepts up to 200 A of charging current, its maximum discharge current is 3800 A, and the cell weighs 77 kg. Construction is tubular-plate, gel-electrolyte VRLA in an A.B.S. (UL94-HB) container, with UL94-V0 optional, terminated on thread insert & bolt hardware (F10-M8). The cell measures 233 × 210 × 681 mm (width × height × depth). Float charging runs at 2.25-2.3 V, maximum charging voltage is 2.4 V and cycle service voltage 2.37-2.4 V, while discharge cuts off between 1.6 V and 1.9 V. Self-discharge stays under 2% per month. Charging is rated 0-50 °C, discharging -40 to 70 °C and storage -20 to 60 °C, with 20-30 °C optimal. We are an authorised Felicity Solar distributor and supply the OPZV-1000AH-2V from our own stock; warranty is 2 Years.
Specifications last updated 23 March 2026
| Battery Type | Gel, Tubular Plate, VRLA |
|---|---|
| Cut-Off Voltage | 1.6-1.9 V |
| Cycle Service Voltage | 2.37-2.4 V |
| Float Charging Voltage | 2.25-2.3 V |
| Internal Resistance | 0.45 mΩ |
| Max Charging Current | 200 A |
| Max Charging Voltage | 2.4 V |
| Max Discharge Current | 3800 A |
|---|---|
| Nominal Capacity | 1000 Ah |
| Nominal Energy | 2 kWh |
| Nominal Voltage | 2 V |
| Voltage per Unit | 2 V |
| Self-Discharge per Month | <2 %/month |
| Capacity Rating Basis | 10hr-rate to 1.8V per cell @25°C |
|---|---|
| Cells per Unit | 1 |
| Container Material | A.B.S. (UL94-HB), and UL94-V0 is optional |
| Terminal Type | Thread insert & Bolt (F10-M8) |
| Charging Temperature Range | 0-50 °C |
|---|---|
| Discharging Temperature Range | -40 to 70 °C |
| Optimal Operating Temperature | 20-30 °C |
| Storage Temperature Range | -20 to 60 °C |
1000 Ah, which is 2 kWh at the 2 V nominal voltage, rated at the 10-hour rate to 1.8 V per cell at 25 °C. The unit is a single cell, and self-discharge stays under 2% per month.
200 A is the maximum charging current. Float charging voltage is 2.25-2.3 V, maximum charging voltage is 2.4 V and cycle service voltage is 2.37-2.4 V. Charging is rated from 0 to 50 °C.
77 kg per cell, measuring 233 × 210 × 681 mm (width × height × depth). The container is A.B.S. (UL94-HB) with UL94-V0 optional, and the terminals are thread insert & bolt (F10-M8).
3800 A is the maximum discharge current, with internal resistance of 0.45 mΩ and a cut-off voltage of 1.6-1.9 V. Discharging is rated -40 to 70 °C, storage -20 to 60 °C, and 20-30 °C is optimal.