UVP-DCHGFault

Felicity battery error UVP-DCHG

Low Voltage / Over-Discharge Protection in Discharging

Faultthe battery enters fault protection and stops normal operation until the fault is cleared — how it is shown (LED pattern or display code) depends on the model.

FLB48314TG1

BatteryFault

What it means

Low Voltage / Over-Discharge Protection in DischargingVoltage of any battery cell or total voltage falls below rated protection value during discharging. Over-discharging protection activated; battery stops supplying power externally.

Cause: The voltage of a cell or of the whole pack fell below the rated protection value during discharging — the battery was run down too deeply — so it stopped supplying power externally.

How to fix it

  1. Protection released once voltage of each cell returns to rated range.
  2. Recharge within 18 hours.

Source: Felicity-FLB48314TG1-Manual.pdf

Frequently asked questions

What does error UVP-DCHG mean on a Felicity battery?
UVP-DCHG means: Low Voltage / Over-Discharge Protection in Discharging. The voltage of a cell or of the whole pack fell below the rated protection value during discharging — the battery was run down too deeply — so it stopped supplying power externally.
Is error UVP-DCHG a fault or a warning?
UVP-DCHG is a fault code: the battery enters protection and stops normal operation until it is cleared.
How do I clear or fix error UVP-DCHG?
Protection released once voltage of each cell returns to rated range. Recharge within 18 hours.