Fault

T4

Hoher Lade-/Entladestrom verursacht Ausgangsabschaltung.

1 Devices that report this code

What does the T4 error code mean?

T4 on a Felicity unit indicates: Hoher Lade-/Entladestrom verursacht Ausgangsabschaltung.. It is a fault-severity event that can appear on 1 device in the Felicity catalog. The same code may have slightly different recommended fixes depending on the device — the per-device sections below show the exact wording from each device's official manual.

This is a fault-severity code

Fault codes stop normal operation but the unit may attempt to recover. Common causes are out-of-range conditions (voltage, current, temperature) that require checking inputs and outputs before restart.

What triggers this code

T4 is triggered when the unit's protection or monitoring logic detects the specific condition described above. The exact trigger depends on the device — see the per-device sections for the official manual entry for each.

T4Hoher Lade-/Entladestrom verursacht Ausgangsabschaltung.Fault
Description

High current charging and discharging causes output cutoff. Maintenance troubleshooting item (no LCD code).

Cause

The charging and discharging current set on the inverter is too high (Lade- und Entladestrom am Wechselrichter zu hoch).

Recommended fix

Set the charging and discharging current on the inverter according to the recommended values in the battery manual (60A x N, max 400A).

Source:Benutzerhandbuch - Felicity FLS48100SG2.pdf · page 27

Frequently asked about T4

What is the T4 error on Felicity?
T4 on a Felicity unit means: Hoher Lade-/Entladestrom verursacht Ausgangsabschaltung.. It can appear on 1 device in the Felicity catalog. The cause and recommended fix are listed for each device on this page.
Can I clear the T4 code myself?
It depends on the severity. Warning-level codes can usually be cleared by following the recommended fix. Fault and critical codes often require checking the source condition first; if the code returns immediately after restart, escalate to authorized service.
Is the T4 fix the same on every device?
The cause is consistent — it's the same protection logic. The exact fix wording can differ per device because each official manual addresses model-specific context (input ranges, parallel-config notes, firmware revisions). Use the per-device section that matches your unit.
Where does this information come from?
Every entry is sourced directly from the official Felicity user manual for the affected device. The "Source" line at the bottom of each device's section shows the manual filename and page number.

Compiled from official Felicity user manuals. Always consult your device manual and a qualified technician before performing repairs.