Fault

F43

Parallel CAN COMM abnormality.

6 Devices that report this code
F43Parallel CAN COMM abnormality.Fault
Description

Parallel CAN communication abnormality.

Cause

Parallel CAN COMM abnormality.

Recommended fix

Test the parallel communication line, restart still have problems please contact the after-sales service.

Source:Apollo-5KLP1G01-All-in-one-ESS-User-Guide.pdf · page 44
F43Current feedback into the inverter is detected.Fault
Description

Fault: Current feedback into the inverter is detected.

Cause

Reverse-connected L/N cables or improper sharing-cable wiring in parallel/three-phase systems.

Recommended fix

1. Restart the inverter. 2. Check if L/N cables are not connected reversely in all inverters. 3. For parallel system in single phase, make sure the sharing cables are connected in all inverters. For supporting three-phase system, make sure the sharing cables are connected in the inverters in the same phase, and disconnected in the inverters in different phases. 4. if the problem remains, please contact your installer.

Source:felicitysolar IVEM 6048 Solar Inverter User Guide.pdf · page 38
F43Current feedback into the inverter is detected.Fault
Description

Fault: Current feedback into the inverter is detected.

Cause

Reverse current feedback detected at the inverter.

Recommended fix

1. Restart the inverter. 2. Check if L/N cables are not connected reversely in all inverters. 3. For parallel system in single phase, make sure the sharing cables are connected in all inverters. For supporting three-phase system, make sure the sharing cables are connected in the inverters in the same phase, and disconnected in the inverters in different phases. 4. if the problem remains, please contact your installer.

Source:IVEM8K-12K-II_compressed.pdf · page 45
F43Current feedback into the inverter is detected.Fault
Description

Current feedback into the inverter is detected.

Cause

Reverse-connected L/N cables, or sharing cables not connected/connected across phases in three-phase setup.

Recommended fix

1. Restart the inverter. 2. Check if L/N cables are not connected reversely in all inverters. 3. For parallel system in single phase, make sure the sharing cables are connected in all inverters. For supporting three-phase system, make sure the sharing cables are connected in the inverters in the same phase, and disconnected in the inverters in different phases. 4. if the problem remains, please contact your installer.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf · page 39
F43CAN data loss.Fault
Description

Loss of CAN bus communication data.

Recommended fix

Check if communication cables are connected well and restart the inverter. if the problem remains, please contact your installer.

Source:T-REX-10KHP3G01-Inverter-User-Guide.pdf · page 29
F43CAN data loss.Fault
Description

CAN data loss.

Cause

Communication cables not connected well.

Recommended fix

1. Check if communication cables are connected well and restart the inverter. 2. if the problem remains, please contact your installer.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf · page 29