Critical

F28

The DC component of the inverter current is abnormal.

7 Devices that report this code
F28The DC component of the inverter current is abnormal.Critical
Description

The DC component of the inverter current is abnormal.

Cause

The DC component of the inverter current is abnormal.

Recommended fix

Restart the unit, if the error persists, contact the repair center.

Source:Apollo-5KLP1G01-All-in-one-ESS-User-Guide.pdf · page 43
F28Single unit is installed to parallel system.Fault
Description

Fault: Single unit is installed to parallel system.

Cause

A single unit configuration was installed where parallel was expected.

Recommended fix

1. Please check if single unit is installed to parallel system. 2. if this error happens during parallel installation, please check wires connectiotn. if they are connected correctly, please funish parallel installation first, and then restart inverters. 3. if the problem remains, please contact your installer.

Source:felicitysolar IVEM 6048 Solar Inverter User Guide.pdf · page 38
F28Single unit is installed to parallel system.Fault
Description

Fault: Single unit is installed to parallel system.

Cause

A single unit is detected as installed in a parallel system.

Recommended fix

1. Please check if single unit is installed to parallel system. 2. if this error happens during parallel installation, please check wires connectiotn. if they are connected correctly, please funish parallel installation first, and then restart inverters. 3. if the problem remains, please contact your installer.

Source:IVEM8K-12K-II_compressed.pdf · page 44
F28Single unit is installed to parallel system.Fault
Description

Single unit is installed to parallel system.

Cause

Single unit configured into a parallel system, or wiring problem during parallel installation.

Recommended fix

1. Please check if single unit is installed to parallel system. 2. if this error happens during parallel installation, please check wires connection. if they are connected correctly, please funish parallel installation first, and then restart inverters. 3. if the problem remains, please contact your installer.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf · page 39
F28The DC component of the inverter current is abnormal.Fault
Description

Abnormal DC component detected in inverter current.

Recommended fix

Restart the unit, if the error persists, contact the repair center.

Source:T-REX-10KHP3G01-Inverter-User-Guide.pdf · page 28
F28The DC component of the inverter current is abnormal.Fault
Description

The DC component of the inverter current is abnormal.

Recommended fix

Restart the unit, if the error persists, contact the repair center.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf · page 28
F28Battery 1 relay short circuit fault.Fault
Description

Battery 1 relay not properly disconnected causing short circuit, shutdown and restart.

Source:T-REX-50KHP3G01-user-manual-.pdf · page 46

Compiled from official FelicityESS user manuals. Always consult your device manual and a qualified technician before performing repairs.