Critical

F25

Hardware detect over current at inverter port.

7 Devices that report this code

What does the F25 error code mean?

F25 on a Felicity unit indicates: Hardware detect over current at inverter port.. It is a critical-severity event that can appear on 7 different devices in the Felicity catalog. The same code may have slightly different recommended fixes depending on the device — the per-device sections below show the exact wording from each device's official manual.

This is a critical-severity code

Critical codes trip the unit offline immediately. They typically indicate hardware failure (short-circuit, IGBT, BMS) or an unsafe operating condition. Do not bypass the fault — note the code and contact authorized service.

What triggers this code

F25 is triggered when the unit's protection or monitoring logic detects the specific condition described above. The exact trigger depends on the device — see the per-device sections for the official manual entry for each.

F25Hardware detect over current at inverter port.Critical
Description

Hardware detected over current at inverter port.

Cause

Hardware detect over current at inverter port.

Recommended fix

Restart the unit, if the error persists, contact the repair center.

Source:Apollo-5KLP1G01-All-in-one-ESS-User-Guide.pdf · page 43
F25OP current sensor failed.Fault
Description

Fault: OP current sensor failed.

Cause

Output current sensor hardware failure.

Recommended fix

Restart the unit, if the error persists, contact the repair center.

Source:felicitysolar IVEM 6048 Solar Inverter User Guide.pdf · page 37
F25OP current sensor failed.Fault
Description

Fault: OP current sensor failed.

Cause

Output current sensor failure.

Recommended fix

Restart the unit, if the error persists, contact the repair center.

Source:IVEM8K-12K-II_compressed.pdf · page 44
F25OP current sensor failed.Fault
Description

OP current sensor failed.

Recommended fix

Restart the unit, if the error persists, contact the repair center.

Source:FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf · page 38
F25Hardware detect over current at inverter port.Critical
Description

Hardware-level over current detection at inverter port.

Recommended fix

Restart the unit, if the error persists, contact the repair center.

Source:T-REX-10KHP3G01-Inverter-User-Guide.pdf · page 28
F25Hardware detect over current at inverter port.Fault
Description

Hardware detect over current at inverter port.

Recommended fix

Restart the unit, if the error persists, contact the repair center.

Source:T-REX-10KLP3G01-Inverter-User-Guide.pdf · page 28
F25Battery 2 reverse connection fault.Fault
Description

Battery 2 positive and negative poles is reversed, check the battery wiring.

Source:T-REX-50KHP3G01-user-manual-.pdf · page 46

Frequently asked about F25

What is the F25 error on Felicity?
F25 on a Felicity unit means: Hardware detect over current at inverter port.. It can appear on 7 different devices in the Felicity catalog. The cause and recommended fix are listed for each device on this page.
Can I clear the F25 code myself?
It depends on the severity. Warning-level codes can usually be cleared by following the recommended fix. Fault and critical codes often require checking the source condition first; if the code returns immediately after restart, escalate to authorized service.
Is the F25 fix the same on every device?
The cause is consistent — it's the same protection logic. The exact fix wording can differ per device because each official manual addresses model-specific context (input ranges, parallel-config notes, firmware revisions). Use the per-device section that matches your unit.
Where does this information come from?
Every entry is sourced directly from the official Felicity user manual for the affected device. The "Source" line at the bottom of each device's section shows the manual filename and page number.

Compiled from official Felicity user manuals. Always consult your device manual and a qualified technician before performing repairs.