F01
PV voltage is too high.
F01PV voltage is too high.Fault
PV input voltage exceeds the allowed maximum.
PV voltage is too high.
Reduce the number of PV modules in series.
Apollo-5KLP1G01-All-in-one-ESS-User-Guide.pdf · page 42F01Bus voltage is too high.Fault
Fault: Bus voltage is too high.
AC Surge or internal components failed.
Restart the unit, if the error persists, contact the repair center.
felicitysolar IVEM 6048 Solar Inverter User Guide.pdf · page 36F01Bus voltage is too high.Fault
Fault: Bus voltage is too high. Inverter cuts off output, fault LED solid on, ERROR icon shown on LCD.
AC Surge or internal components failed.
Restart the unit, if the error persists, contact the repair center.
IVEM8K-12K-II_compressed.pdf · page 42F01Bus voltage is too high.Fault
Bus voltage is too high.
AC Surge or internal components failed.
Restart the unit, if the error persists, contact the repair center.
FelicitySolar IVEM8048-LV Single Phase Hybrid Inverter User Guide.pdf · page 37F01PV voltage is too high.Fault
PV input voltage exceeds permitted range.
Too many PV modules connected in series.
Reduce the number of PV modules in series.
T-REX-10KHP3G01-Inverter-User-Guide.pdf · page 28F01PV voltage is too high.Fault
PV voltage is too high.
PV input voltage exceeds inverter limits (too many PV modules in series).
Reduce the number of PV modules in series.
T-REX-10KLP3G01-Inverter-User-Guide.pdf · page 27F01PV1 overvoltage fault.Fault
The voltage of the PV1 is too high, check the voltage of the string.
T-REX-50KHP3G01-user-manual-.pdf · page 45Compiled from official FelicityESS user manuals. Always consult your device manual and a qualified technician before performing repairs.