LUX-E-48100LG04

Batterie12 codes
12 Défaut
FAULT (RED ON, LED1=OFF, LED2=OFF, LED3=OFF, LED4=ON)BMS TEMPERATURE LOW.Défaut
Cause

BMS internal temperature fell below the lower protection threshold.

Correction recommandée

Warm the installation environment (operating range Charge: 0°C–55°C, Discharge: -20°C–55°C). The fault will self-clear once temperature returns to range. if the fault persists, contact the local distributor.

Source:LUX-E-48100LG04-Lithium-Battery-User-Guide.pdf · page 12
FAULT (RED ON, LED1=OFF, LED2=OFF, LED3=ON, LED4=OFF)CELL VOLTAGE LOW.Défaut
Cause

An individual cell voltage fell below the lower cell protection threshold.

Correction recommandée

Recharge the battery promptly. The BMS will self-recover once cell voltage recovers. if the fault persists, contact the local distributor.

Source:LUX-E-48100LG04-Lithium-Battery-User-Guide.pdf · page 12
FAULT (RED ON, LED1=OFF, LED2=ON, LED3=OFF, LED4=OFF)BATTERY VOLTAGE LOW.Défaut
Cause

Total battery pack voltage fell below the BMS lower protection threshold (undervoltage protection).

Correction recommandée

Recharge the battery promptly (per section 10.1, the battery should be charged in time when undercharged or stored more than 3 months). The BMS will automatically return to normal once voltage recovers. if the fault persists, contact the local distributor.

Source:LUX-E-48100LG04-Lithium-Battery-User-Guide.pdf · page 12
FAULT (RED ON, LED1=OFF, LED2=ON, LED3=OFF, LED4=ON)CELL TEMPERATURE LOW.Défaut
Cause

An individual cell temperature fell below the lower protection threshold (charge: below 0°C; discharge: below -20°C).

Correction recommandée

Warm the environment until cells are within the operating range (Charge: 0°C–55°C, Discharge: -20°C–55°C). The fault will self-clear once temperature normalises. if the fault persists, contact the local distributor.

Source:LUX-E-48100LG04-Lithium-Battery-User-Guide.pdf · page 12
FAULT (RED ON, LED1=OFF, LED2=ON, LED3=ON, LED4=OFF)DISCHARGING CURRENT HIGH.Défaut
Cause

Discharging current exceeded the BMS overcurrent protection threshold.

Correction recommandée

Reduce load current; verify the load is within the recommended 50A and max-continuous 60A limits (peak 100A for 15s). The BMS will self-recover once current returns to normal. if the fault persists, contact the local distributor.

Source:LUX-E-48100LG04-Lithium-Battery-User-Guide.pdf · page 12
FAULT (RED ON, LED1=ON, LED2=OFF, LED3=OFF, LED4=OFF)BATTERY VOLTAGE HIGH.Défaut
Cause

Total battery pack voltage exceeded the BMS upper protection threshold (overvoltage protection).

Correction recommandée

Stop charging and allow voltage to drop. The BMS will automatically return to normal once the trigger condition is removed. if the fault persists, contact the local distributor.

Source:LUX-E-48100LG04-Lithium-Battery-User-Guide.pdf · page 12
FAULT (RED ON, LED1=ON, LED2=OFF, LED3=OFF, LED4=ON)CELL TEMPERATURE HIGH.Défaut
Cause

An individual cell temperature exceeded the upper protection threshold.

Correction recommandée

Stop charging/discharging and allow the cell to cool; check ambient temperature is within the operating range. The fault will self-clear once temperature normalises. if the fault persists, contact the local distributor.

Source:LUX-E-48100LG04-Lithium-Battery-User-Guide.pdf · page 12
FAULT (RED ON, LED1=ON, LED2=OFF, LED3=ON, LED4=OFF)CHARGING CURRENT HIGH.Défaut
Cause

Charging current exceeded the BMS overcurrent protection threshold.

Correction recommandée

Reduce charging current; verify charger/inverter is configured within the recommended 50A and max-continuous 60A limits (peak 100A for 15s). The BMS will self-recover once current returns to normal. if the fault persists, contact the local distributor.

Source:LUX-E-48100LG04-Lithium-Battery-User-Guide.pdf · page 12
FAULT (RED ON, LED1=ON, LED2=ON, LED3=OFF, LED4=OFF)CELL VOLTAGE HIGH.Défaut
Cause

An individual cell voltage exceeded the upper cell protection threshold.

Correction recommandée

Stop charging and allow the affected cell voltage to drop. The BMS will self-recover once the trigger condition is removed. if the fault persists, contact the local distributor.

Source:LUX-E-48100LG04-Lithium-Battery-User-Guide.pdf · page 12
FAULT (RED ON, LED1=ON, LED2=ON, LED3=OFF, LED4=ON)CURRENT SENSOR ABNORMAL.Défaut
Cause

BMS detected an abnormal reading from the current-sampling circuit / current sensor.

Correction recommandée

Restart the battery (turn breaker OFF then ON, press POWER for 1 second). if the fault persists, contact the local distributor (per section 10.2: when the LED does not light up or flash on power-up, consider contacting the local distributor).

Source:LUX-E-48100LG04-Lithium-Battery-User-Guide.pdf · page 12
FAULT (RED ON, LED1=ON, LED2=ON, LED3=ON, LED4=OFF)BMS TEMPERATURE HIGH.Défaut
Cause

BMS internal (MOSFET / control board) temperature exceeded the upper protection threshold.

Correction recommandée

Check the ambient temperature and cooling space around the unit (per section 8.3 ambient must be 0°C–45°C). Allow the BMS to cool. The fault will self-clear once temperature returns to range. if the fault persists, contact the local distributor.

Source:LUX-E-48100LG04-Lithium-Battery-User-Guide.pdf · page 12
LOW POWER (GREEN FLASH, RED OFF, all LEDs OFF)Low Power / Low SOC shutdown.Défaut
Cause

Battery state-of-charge is critically low and the system has entered low-power state with output disabled.

Correction recommandée

Recharge the battery. Per section 10.1, charge the battery in time if it is often under-charged or has been stored for more than 3 months. The system will return to normal once charging restores SOC.

Source:LUX-E-48100LG04-Lithium-Battery-User-Guide.pdf · page 12