IVEM 6048

Onduleur49 codes
also coversIVEM6048
40 Défaut 9 Avertissement
F01Bus voltage is too high.Défaut
Description

Fault: Bus voltage is too high.

Cause

AC Surge or internal components failed.

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:felicitysolar IVEM 6048 Solar Inverter User Guide.pdf · page 36
F02Bus voltage is too low.Défaut
Description

Fault: Bus voltage is too low.

Cause

Internal components failed (inferred from similar fault classes).

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:felicitysolar IVEM 6048 Solar Inverter User Guide.pdf · page 36
F03Bus soft start fail.Défaut
Description

Fault: Bus soft start fail.

Cause

Internal components failed.

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:felicitysolar IVEM 6048 Solar Inverter User Guide.pdf · page 36
F04Inverter soft start fail.Défaut
Description

Fault: Inverter soft start fail.

Cause

Internal components failed.

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:felicitysolar IVEM 6048 Solar Inverter User Guide.pdf · page 36
F05Over current or surge detected by Software.Défaut
Description

Fault: Over current or surge detected by Software.

Cause

Software-detected overcurrent or surge condition.

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:felicitysolar IVEM 6048 Solar Inverter User Guide.pdf · page 36
F06Over current or surge detected by hardware.Défaut
Description

Fault: Over current or surge detected by hardware.

Cause

Hardware-detected overcurrent or surge condition.

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:felicitysolar IVEM 6048 Solar Inverter User Guide.pdf · page 36
F07Output voltage is too low.Défaut
Description

Fault: Output voltage is too low.

Cause

Connected load is too high or internal failure.

Correction recommandée

Reduce the connected load. Restart the unit, if the error persists, contact the repair center.

Source:felicitysolar IVEM 6048 Solar Inverter User Guide.pdf · page 37
F08Output voltage is too high.Défaut
Description

Fault: Output voltage is too high.

Cause

Internal failure causing high output voltage.

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:felicitysolar IVEM 6048 Solar Inverter User Guide.pdf · page 37
F09Output short circuited.Défaut
Description

Fault: Output short circuited.

Cause

Wiring issue or abnormal load causing a short circuit.

Correction recommandée

Check if wiring is connected well and remove abnormal load.

Source:felicitysolar IVEM 6048 Solar Inverter User Guide.pdf · page 37
F10Overload time out.Défaut
Description

Fault: Overload time out.

Cause

Sustained overload condition.

Correction recommandée

Reduce the connected load by switching off some equipment.

Source:felicitysolar IVEM 6048 Solar Inverter User Guide.pdf · page 37
F11Battery voltage is too high.Défaut
Description

Fault: Battery voltage is too high.

Cause

Battery spec/quantity does not meet inverter requirements.

Correction recommandée

Check if spec and quantity of batteries are meet requirements.

Source:felicitysolar IVEM 6048 Solar Inverter User Guide.pdf · page 37
F12Over current happen at DCDC circuit.Défaut
Description

Fault: Over current happen at DCDC circuit.

Cause

Overcurrent in the DC/DC stage.

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:felicitysolar IVEM 6048 Solar Inverter User Guide.pdf · page 37
F13PV voltage is too high.Défaut
Description

Fault: PV voltage is too high.

Cause

Too many PV modules connected in series.

Correction recommandée

Reduce the number of PV modules in series.

Source:felicitysolar IVEM 6048 Solar Inverter User Guide.pdf · page 37
F14Short circuited happen at PV port.Défaut
Description

Fault: Short circuited happen at PV port.

Cause

Wiring issue causing short at PV port.

Correction recommandée

Check if wiring is connected well.

Source:felicitysolar IVEM 6048 Solar Inverter User Guide.pdf · page 37
F15PV power is abnormal.Défaut
Description

Fault: PV power is abnormal.

Cause

PV power exceeds normal limits (too many PV modules).

Correction recommandée

Reduce the number of PV modules.

Source:felicitysolar IVEM 6048 Solar Inverter User Guide.pdf · page 37
F16Over current happen at PV port.Défaut
Description

Fault: Over current happen at PV port.

Cause

Overcurrent at the PV input.

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:felicitysolar IVEM 6048 Solar Inverter User Guide.pdf · page 37
F17Fan is locked.Défaut
Description

Fault: Fan is locked.

Cause

Fan wiring not connected well or fan failed.

Correction recommandée

Check if wiring is connected well. Replace the fan.

Source:felicitysolar IVEM 6048 Solar Inverter User Guide.pdf · page 37
F18Over temperature happen at PV circuit.Défaut
Description

Fault: Over temperature happen at PV circuit.

Cause

The temperature of internal PV converter component is over the limitation.

Correction recommandée

Check whether the air flow of the unit is blocked or whether the ambient temperature is too high.

Source:felicitysolar IVEM 6048 Solar Inverter User Guide.pdf · page 37
F19Over temperature happen at battery circuit.Défaut
Description

Fault: Over temperature happen at battery circuit.

Cause

The temperature of internal battery converter component is over the limitation.

Correction recommandée

Check whether the air flow of the unit is blocked or whether the ambient temperature is too high.

Source:felicitysolar IVEM 6048 Solar Inverter User Guide.pdf · page 37
F20Over temperature happen at inverter circuit.Défaut
Description

Fault: Over temperature happen at inverter circuit.

Cause

The temperature of internal inverter component is over the limitation.

Correction recommandée

Check whether the air flow of the unit is blocked or whether the ambient temperature is too high.

Source:felicitysolar IVEM 6048 Solar Inverter User Guide.pdf · page 37
F21The inner temperature over.Défaut
Description

Fault: The inner temperature over.

Cause

The inner temperature is over the limitation.

Correction recommandée

Check whether the air flow of the unit is blocked or whether the ambient temperature is too high.

Source:felicitysolar IVEM 6048 Solar Inverter User Guide.pdf · page 37
F22DCDC current sensor failed.Défaut
Description

Fault: DCDC current sensor failed.

Cause

DC/DC current sensor hardware failure.

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:felicitysolar IVEM 6048 Solar Inverter User Guide.pdf · page 37
F23No.2 DCDC current sensor failed.Défaut
Description

Fault: No.2 DCDC current sensor failed.

Cause

Second DC/DC current sensor hardware failure.

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:felicitysolar IVEM 6048 Solar Inverter User Guide.pdf · page 37
F24Inverter current sensor failed.Défaut
Description

Fault: Inverter current sensor failed.

Cause

Inverter current sensor hardware failure.

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:felicitysolar IVEM 6048 Solar Inverter User Guide.pdf · page 37
F25OP current sensor failed.Défaut
Description

Fault: OP current sensor failed.

Cause

Output current sensor hardware failure.

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:felicitysolar IVEM 6048 Solar Inverter User Guide.pdf · page 37
F26Sharing current sensor failed.Défaut
Description

Fault: Sharing current sensor failed.

Cause

Sharing current sensor hardware failure (parallel operation).

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:felicitysolar IVEM 6048 Solar Inverter User Guide.pdf · page 37
F27The AC input and output wires are inversely connected.Défaut
Description

Fault: The AC input and output wires are inversely connected.

Cause

AC input and output wires are reversed.

Correction recommandée

1. Please check AC input and output wires are connected correctly. 2. if this error happens during parallel installation, please check wires connection. if they are connected correctly, please funish parallel installation first, and then restart inverters. 3. if the problem remains, please contact your installer.

Source:felicitysolar IVEM 6048 Solar Inverter User Guide.pdf · page 38
F28Single unit is installed to parallel system.Défaut
Description

Fault: Single unit is installed to parallel system.

Cause

A single unit configuration was installed where parallel was expected.

Correction recommandée

1. Please check if single unit is installed to parallel system. 2. if this error happens during parallel installation, please check wires connectiotn. if they are connected correctly, please funish parallel installation first, and then restart inverters. 3. if the problem remains, please contact your installer.

Source:felicitysolar IVEM 6048 Solar Inverter User Guide.pdf · page 38
F29DC/DC soft start fail.Défaut
Description

Fault: DC/DC soft start fail.

Cause

Internal failure during DC/DC soft start.

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:felicitysolar IVEM 6048 Solar Inverter User Guide.pdf · page 38
F31Over temperature happen at convert H circuit.Défaut
Description

Fault: Over temperature happen at convert H circuit.

Cause

The temperature of internal convert H component is over the limitation.

Correction recommandée

Check whether the air flow of the unit is blocked or whether the ambient temperature is too high.

Source:felicitysolar IVEM 6048 Solar Inverter User Guide.pdf · page 38
F32Over temperature happen at LLC TX.Défaut
Description

Fault: Over temperature happen at LLC TX.

Cause

The temperature of internal DC/DC TX is over the limitation.

Correction recommandée

Check whether the air flow of the unit is blocked or whether the ambient temperature is too high.

Source:felicitysolar IVEM 6048 Solar Inverter User Guide.pdf · page 38
F33Over current happen at LLC circuit.Défaut
Description

Fault: Over current happen at LLC circuit.

Cause

Overcurrent in LLC resonant circuit.

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:felicitysolar IVEM 6048 Solar Inverter User Guide.pdf · page 38
F35Overvoltage occurs in BUS.Défaut
Description

Fault: Overvoltage occurs in BUS.

Cause

AC surge or PV surge or internal components failed.

Correction recommandée

Restart the unit, if the error persists, contact the repair center.

Source:felicitysolar IVEM 6048 Solar Inverter User Guide.pdf · page 38
F40CAN data loss.Défaut
Description

Fault: CAN data loss.

Cause

Communication cable connection issue between paralleled inverters.

Correction recommandée

1. Check if communication cables are connected well and restart the inverter. 2. if the problem remains, please contact your installer.

Source:felicitysolar IVEM 6048 Solar Inverter User Guide.pdf · page 38
F41Host data loss.Défaut
Description

Fault: Host data loss.

Cause

Communication cable connection issue between paralleled inverters.

Correction recommandée

1. Check if communication cables are connected well and restart the inverter. 2. if the problem remains, please contact your installer.

Source:felicitysolar IVEM 6048 Solar Inverter User Guide.pdf · page 38
F42Synchronization data loss.Défaut
Description

Fault: Synchronization data loss.

Cause

Communication cable connection issue between paralleled inverters.

Correction recommandée

1. Check if communication cables are connected well and restart the inverter. 2. if the problem remains, please contact your installer.

Source:felicitysolar IVEM 6048 Solar Inverter User Guide.pdf · page 38
F43Current feedback into the inverter is detected.Défaut
Description

Fault: Current feedback into the inverter is detected.

Cause

Reverse-connected L/N cables or improper sharing-cable wiring in parallel/three-phase systems.

Correction recommandée

1. Restart the inverter. 2. Check if L/N cables are not connected reversely in all inverters. 3. For parallel system in single phase, make sure the sharing cables are connected in all inverters. For supporting three-phase system, make sure the sharing cables are connected in the inverters in the same phase, and disconnected in the inverters in different phases. 4. if the problem remains, please contact your installer.

Source:felicitysolar IVEM 6048 Solar Inverter User Guide.pdf · page 38
F44The firmware version of each inverter is not the same.Défaut
Description

Fault: The firmware version of each inverter is not the same.

Cause

CPU/firmware versions differ between paralleled inverters.

Correction recommandée

1. Update all inverter firmware to the same version. 2. Check the version of each inverter via LCD setting and make sure the CPU versions are same. if not, please contact your installer to provide the firmware to update. 3. After updating, if the problem still remains, please contact your installer.

Source:felicitysolar IVEM 6048 Solar Inverter User Guide.pdf · page 38
F45The output current of each inverter is different.Défaut
Description

Fault: The output current of each inverter is different.

Cause

Sharing cables not connected well between paralleled inverters.

Correction recommandée

1. Check if sharing cables are connected well and restart the inverter. 2. if the problem remains, please contact your installer.

Source:felicitysolar IVEM 6048 Solar Inverter User Guide.pdf · page 39
F46AC output mode setting is different.Défaut
Description

Fault: AC output mode setting is different.

Cause

Inconsistent AC output mode (program 28) settings across paralleled inverters.

Correction recommandée

1. Switch off the inverter and check LCD setting program 28. 2. For parallel system in single phase, make sure no 3P1, 3P2 or 3P3 is set on program 28. For supporting three-phase system, make sure no "PAL" is set on program 28. 3. if the problem remains, please contact your installer.

Source:felicitysolar IVEM 6048 Solar Inverter User Guide.pdf · page 39
W01Fan is locked.Avertissement
Description

Warning: Fan is locked. Beep three times every second.

Cause

Fan wiring not connected well or fan failure.

Correction recommandée

Check if the Fan's wiring connected well. Replace the fan.

Source:felicitysolar IVEM 6048 Solar Inverter User Guide.pdf · page 36
W02Overload.Avertissement
Description

Warning: Overload. Beep twice every second.

Cause

Connected load exceeds the inverter capacity.

Correction recommandée

Reduce the loads.

Source:felicitysolar IVEM 6048 Solar Inverter User Guide.pdf · page 36
W03Low battery.Avertissement
Description

Warning: Low battery. Beep once every second.

Cause

The battery voltage is too low.

Correction recommandée

The battery voltage is too low, it should be charging.

Source:felicitysolar IVEM 6048 Solar Inverter User Guide.pdf · page 36
W50BMS firmware version is not matched.Avertissement
Description

Warning: BMS firmware version is not matched.

Cause

BMS firmware version mismatch.

Correction recommandée

Upgrade the firmware of BMS.

Source:felicitysolar IVEM 6048 Solar Inverter User Guide.pdf · page 36
W51BMS doesn't allow inverter to charge battery.Avertissement
Description

Warning: BMS doesn't allow inverter to charge battery.

Cause

BMS has prohibited charging.

Correction recommandée

Inverter will stop charging battery automatically.

Source:felicitysolar IVEM 6048 Solar Inverter User Guide.pdf · page 36
W52BMS doesn't allow inverter to discharge battery.Avertissement
Description

Warning: BMS doesn't allow inverter to discharge battery.

Cause

BMS has prohibited discharging.

Correction recommandée

Inverter will stop discharging battery automatically.

Source:felicitysolar IVEM 6048 Solar Inverter User Guide.pdf · page 36
W53BMS require inverter to charge battery.Avertissement
Description

Warning: BMS require inverter to charge battery.

Cause

BMS has requested charging.

Correction recommandée

Inverter will charge battery automatically.

Source:felicitysolar IVEM 6048 Solar Inverter User Guide.pdf · page 36
W54~65BMS detect something wrongs happened.Avertissement
Description

Warning: BMS detect something wrongs happened (range covering codes 54 through 65).

Cause

BMS has detected an internal abnormality.

Correction recommandée

If the code is keeping for long time, please contact with your installer.

Source:felicitysolar IVEM 6048 Solar Inverter User Guide.pdf · page 36
W80BMS communication fault.Avertissement
Description

Warning: BMS communication fault.

Cause

Communication line between BMS and inverter is not connected well.

Correction recommandée

Check if the communication line is connected well.

Source:felicitysolar IVEM 6048 Solar Inverter User Guide.pdf · page 36

Compilé à partir des manuels utilisateur officiels FelicityESS. Consultez toujours le manuel de votre appareil et un technicien qualifié avant toute réparation.