Output lossFault

Felicity battery error Output loss

Output loss

Faultthe battery enters fault protection and stops normal operation until the fault is cleared — how it is shown (LED pattern or display code) depends on the model.

LUX-X-48050LG01

BatteryFault

Also applies to:LUX-X-48050LCG01LUX-X-48050LMG01LUX-X-48050LG01M2LUX-X-48050LG01M3LUX-X-48050LG01M4

What it means

Output lossOutput power loss / no output.

Cause: No output from the battery pack — the circuit breaker may be open or the fuse may be blown.

How to fix it

  1. Please check whether the circuit breaker is closed
  2. Please check whether the fuse is normal
  3. Restart the unit, if the error persists, contact the repair center.

Source: LUX-X-48050LG01-low-voltage-battery-user-guide.pdf, p.17

Frequently asked questions

What does error Output loss mean on a Felicity battery?
Output loss means: Output loss. No output from the battery pack — the circuit breaker may be open or the fuse may be blown.
Is error Output loss a fault or a warning?
Output loss is a fault code: the battery enters protection and stops normal operation until it is cleared.
How do I clear or fix error Output loss?
1. Please check whether the circuit breaker is closed; 2.