Felicity Solar IVPS3524P1G1-LV

Felicity Solar Inverter Datasheet — IVPS3524P1G1-LV

A 2.8 kW single-phase inverter/charger built for 120 V supplies: 110-127 V output, an 80-140 V input window, 40 A three-stage charging on a 24 V bank, and up to eight units in parallel.

SKU: IVPS3524P1G1-LV | Last Updated: 2026-07-23

⚡Electrical Specifications

AC Output Voltage110-127 V
AC Wiring ModeL-N
Backup Rated Output Power2.8 kW
Battery Inputs1
Battery TypeAGM, Flooded, Li-Ion, Self-Defined
Battery Voltage Range21-31.5 V
Bulk Charging Voltage28.8 V
Charge AlgorithmThree-Stage: Boost CC, Boost CV, Float
Float Charging Voltage27.2 V
High DC Input Recovery Voltage31 V
High Frequency Disconnect65 Hz
High Frequency Reconnect63 Hz
High Line Disconnect Voltage140 V
High Line Reconnect Voltage135 V
Input Voltage Range80-140 V
Input Voltage Range (Appliance Mode)80-140 V
Input Voltage Range (UPS Mode)90-140 V
Input Voltage WaveformSinusoidal (utility or generator)
Line Mode Efficiency>95 %
Line Mode Output WaveformSame As Input Waveform
Low DC Shutdown (<50% Load)21.5 V
Low DC Shutdown (>50% Load)21 V
Low Frequency Disconnect40 Hz
Low Frequency Reconnect42 Hz
Low Line Disconnect (Appliance Mode)80 V
Low Line Disconnect (UPS Mode)90 V
Low Line Reconnect (Appliance Mode)85 V
Low Line Reconnect (UPS Mode)95 V
Low-Battery Recovery (<50% Load)23.5 V
Low-Battery Recovery (>50% Load)23 V
Max AC Charge Current40 A
Max AC Input Voltage140 V
Max AC Pass-Through Current50 A
Max Charging Current40 A
Max Charging Voltage31.5 V
Max Efficiency90 %
Motor Start CapableYes
Nominal AC Input Voltage110-120 V
Nominal DC Input Voltage24 V
Nominal Input Frequency50/60 Hz
Output Frequency50/60 Hz
Output Short-Circuit ProtectionYes
Output Voltage Regulation5 %
Output Voltage WaveformPure Sine Wave
Overload ProtectionOvercurrent Protector
Overload Trip Time (>105% Load)10 s
Overload Trip Time (>150% Load)5 s
Pass-Through Without BatteryNo
PhaseSingle Phase
ProtectionOver Charge Protection, Over Discharge Protection, Overload Protection, Output Short Circuit Protection, Over Temperature Protection
Rated Apparent Output Power3.5 kVA
Rated Output Power2.8 kW
Short-Circuit Protection (Line Mode)Overcurrent Protector
Start-Up Voltage23 V
Surge Rating2*rated (5s)
Transfer Time15 ms

🔧Mechanical Specifications

BMS CommunicationRS485
Communication InterfaceRS232, RS485
DisplayLCD, LED
Gross Weight30.8 kg
Net Weight27.7 kg
Package Dimensions552 x 508 x 290 mm
Parallel Capability8
TopologyLow-Frequency (transformer-based)

🌡️Environmental Specifications

CoolingIntelligent Air Cooling
IP RatingIP21
Operating Temperature Range0-40 °C
Storage Temperature-15 to 60 °C

📏Dimensions

Width
Height
Depth
Weight