Felicity Solar Inverter Datasheet — IVGM5KLP2G1
Single-phase 5 kW hybrid inverter with a 5.5 kW AC ceiling, 120 A of charge and discharge on a 40-60 V bank, and 13+13 A across two MPP trackers.
SKU: IVGM5KLP2G1 | Last Updated: 2026-08-07
⚡Electrical Specifications
| AC Output Voltage | 220-230 V |
| AC Rated Output Current | 20.8 A |
| AC Wiring Mode | L+N+PE |
| Backup Rated Output Power | 5 kW |
| Battery Inputs | 1 |
| Battery Type | Lead-Acid, Li-Ion |
| Battery Voltage Range | 40-60 V |
| Charge Algorithm | Self-Adaption to BMS |
| European Efficiency | 97 % |
| Grid Frequency Range (50 Hz) | 45-55 Hz |
| Grid Frequency Range (60 Hz) | 55-65 Hz |
| Grid Regulation | CEI 0-21, G99, VDE 4105, EN 50549-1, NRS 097-2-1, C10/11, NTS & UNE217001 & UNE217002, PORTARIA N° 140 & 515 |
| Ground Fault Current Monitoring | Yes |
| MPPT Efficiency | 99.9 % |
| MPPT Full-Load Voltage Range | 290-425 V |
| MPPT Trackers | 2 |
| MPPT Voltage Range | 120-425 V |
| Max AC Input Current | 40 A |
| Max AC Output Power | 5.5 kW |
| Max AC Pass-Through Current | 40 A |
| Max Charge/Discharge Power | 5 kW |
| Max Charging Current | 120 A |
| Max Discharging Current | 120 A |
| Max Efficiency | 97.6 % |
| Max Output Current | 22.9 A |
| Max PV Input Current | 13+13 A |
| Max PV Voltage | 500 V |
| Max Recommended PV Power | 7.5 kW |
| Max Short-Circuit Current | 17+17 A |
| Nominal AC Input Voltage | 220-230 V |
| Nominal Input Frequency | 50/60 Hz |
| Output Frequency | 50/60 Hz |
| Output Short-Circuit Protection | Yes |
| Overload Protection | Yes |
| PV Working Voltage Range | 90-500 V |
| Phase | Single Phase |
| Power Factor | >0.99 |
| Power Factor Adjustment Range | 0.8 leading to 0.8 lagging |
| Protection | Output Over Current Protection, Output Over Power Protection, Output Short-Circuit Protection, Anti-islanding Protection, GFCI Protection, Insulation Resistor Detection |
| Rated Apparent Output Power | 5 kVA |
| Rated Output Power | 5 kW |
| Rated PV Input Voltage | 380 V |
| Start-Up Voltage | 100 V |
| Strings per MPPT | 1+1 |
| Surge Rating | 2*rated (10s) |
| Total Harmonic Distortion | <3 % |
| Transfer Time | 10 ms |
🔧Mechanical Specifications
| BMS Communication | RS485, CAN |
| Communication Interface | RS232, RS485 |
| Display | LCD, LED |
| Gross Weight | 40.5 kg |
| Installation Style | Wall-Mounted |
| Monitoring Module | WiFi/GPRS |
| Net Weight | 33.5 kg |
| Package Dimensions | 787 x 547 x 358 mm |
| Parallel Capability | 6 |
| Safety Standard | IEC 62109-1, IEC 62109-2 |
| Topology | Isolated (transformer-based) |
🌡️Environmental Specifications
| Cooling | Smart Cooling |
| IP Rating | IP65 |
| Noise Level | <35 dB |
| Operating Altitude | 2000 m |
| Operating Temperature Range | -25 to 60 (>45 derating) °C |
| Relative Humidity | 0-95 (non-condensing) % |
📏Dimensions
Width
Height
Depth
Weight
✅Certifications
IEC 62109-1IEC 62109-2