Felicity Solar IVGM100KHP3G1 Hybrid Inverter

Felicity Solar Inverter Datasheet — IVGM100KHP3G1

A three-phase hybrid inverter rated 100kW and 100kVA, the IVGM100KHP3G1 peaks at 110kVA and harvests up to 200kW of PV through 8 MPPT trackers.

SKU: IVGM100KHP3G1 | Last Updated: 2026-08-17

⚡Electrical Specifications

AC Output Line Voltage380-400 V
AC Output Voltage220-230 V
AC Rated Output Current145 A
AC Wiring Mode3L+N+PE
Backup Rated Output Power100 kW
Battery Inputs2
Battery TypeLFP
Battery Voltage Range160-1000 V
Charge AlgorithmSelf-Adaption to BMS
Grid Frequency Range (50 Hz)45-55 Hz
Grid Frequency Range (60 Hz)55-65 Hz
Grid RegulationIEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4110
Ground Fault Current MonitoringYes
Input Voltage Range184-264.5 V
MPPT Full-Load Voltage Range444-850 V
MPPT Trackers8
MPPT Voltage Range150-850 V
Max AC Input Current159.4 A
Max AC Pass-Through Current270 A
Max Apparent Power110 kVA
Max Charging Current120+120 A
Max Discharging Current120+120 A
Max Efficiency97.6 %
Max Output Current159.4 A
Max Output Overcurrent Protection270 A
Max PV Input Current45+45+45+45+45+45+45+45 A
Max PV Input Power200 kW
Max PV Voltage1000 V
Max Short-Circuit Current68+68+68+68+68+68+68+68 A
Nominal AC Input Line Voltage380-400 V
Nominal AC Input Voltage220-230 V
Nominal Input Frequency50/60 Hz
Output Frequency50/60 Hz
Output Short-Circuit ProtectionYes
Overload ProtectionYes
Overvoltage Category (AC)III
Overvoltage Category (DC)II
PhaseThree Phase
Power Factor Adjustment Range0.8 leading to 0.8 lagging
ProtectionPV Input Lightning Protection, PV String Input Reverse Polarity Protection, Battery Input Lightning Protection, Battery Input Reverse Polarity Protection, DC Component Detection, Insulation Resistor Detection, Residual Current Monitoring Unit, Arc Fault Monitoring (optional), Output Over Current Protection, Output Shorted Protection, Output Over Voltage Protection, Remaining Current (RCD) Monitoring, Overheat Protection, Anti-islanding Protection, AC Output Lightning Protection
Rated Apparent Output Power100 kVA
Rated Output Power100 kW
Rated PV Input Voltage600 V
Start-Up Voltage180 V
Strings per MPPT2
Surge Protection Level (AC)III
Surge Protection Level (DC)III
Surge Rating1.5*rated (10s)
Total Harmonic Distortion<3 %
Transfer Time0 ms

🔧Mechanical Specifications

BMS CommunicationRS485, CAN
Communication InterfaceRS232, RS485
DisplayLCD, LED
Gross Weight200 kg
Installation StyleWall-Mounted
Monitoring ModuleWiFi/Bluetooth/4G/LAN
Net Weight156 kg
Package Dimensions1410 x 960 x 646 mm
Parallel Capability12
Safety StandardIEC/EN 62109-1, IEC/EN 62109-2
TopologyNon-Isolated

🌡️Environmental Specifications

CoolingSmart Cooling
IP RatingIP66
Operating Altitude4000 m
Operating Temperature Range-40 to 60 (>45 derating) °C
Relative Humidity0-100 (non-condensing) %

📏Dimensions

Width
Height
Depth
Weight

✅Certifications

IEC 62109-1EN 62109-1IEC 62109-2EN 62109-2