Felicity Solar Inverter Datasheet — IVAM6048P1G1
The Felicity Solar IVAM6048P1G1 is a 6 kW single-phase off-grid solar inverter built around a 48 V battery bank, taking up to 9.6 kW of PV across two MPPT trackers. It peaks at 97.6% efficiency and charges or discharges at up to 135 A.
SKU: IVAM6048P1G1 | Last Updated: 2026-03-23
⚡Electrical Specifications
| AC Output Voltage | 230 V |
| AC Wiring Mode | L+N+PE |
| Backup Rated Output Power | 6 kW |
| Battery Inputs | 1 |
| Battery Type | Lead-Acid, Li-Ion |
| Battery Voltage Range | 40-60 V |
| Charge Algorithm | Self-Adaption to BMS |
| DC Switch | Yes |
| European Efficiency | 96.5 % |
| Ground Fault Current Monitoring | Yes |
| MPPT Efficiency | >99 % |
| MPPT Full-Load Voltage Range | 300-425 V |
| MPPT Trackers | 2 |
| MPPT Voltage Range | 90-425 V |
| Max AC Output Power | 6 kW |
| Max AC Pass-Through Current | 35 A |
| Max Charge/Discharge Power | 6 kW |
| Max Charging Current | 135 A |
| Max Discharging Current | 135 A |
| Max Efficiency | 97.6 % |
| Max Output Current | 26.1 A |
| Max PV Access Power | 12 kW |
| Max PV Input Current | 20+20 A |
| Max PV Input Power | 9.6 kW |
| Max PV Voltage | 500 V |
| Max Short-Circuit Current | 27+27 A |
| Nominal AC Input Voltage | 230 V |
| Nominal DC Input Voltage | 48 V |
| Nominal Input Frequency | 50/60 Hz |
| Output Frequency | 50/60 Hz |
| Output Short-Circuit Protection | Yes |
| Output Voltage Waveform | Pure Sine Wave |
| Overload Protection | Yes |
| Overvoltage Category (AC) | III |
| Overvoltage Category (DC) | II |
| PV Working Voltage Range | 90-500 V |
| Phase | Single Phase |
| Protection | DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, Thermal Protection, DC Terminal Insulation Impedance Monitoring, DC Component Monitoring, Ground Fault Current Monitoring, Arc Fault Circuit Interrupter (optional), Power Network Monitoring, Earth Fault Detection, DC Input Switch, Overvoltage Load Drop Protection |
| Rated Apparent Output Power | 6 kVA |
| Rated Output Power | 6 kW |
| Rated PV Input Voltage | 370 V |
| Start-Up Voltage | 120 V |
| Strings per MPPT | 2+2 |
| Surge Protection Level (AC) | II |
| Surge Protection Level (DC) | II |
| Surge Rating | 2*rated (10s) |
| Total Harmonic Distortion | <3 % |
🔧Mechanical Specifications
| BMS Communication | RS485, CAN |
| Communication Interface | RS485, CAN |
| Display | LCD, LED |
| Gross Weight | 15.4 kg |
| Monitoring Module | WiFi/LAN (optional) |
| Net Weight | 13.5 kg |
| Package Dimensions | 412 x 532 x 270 mm |
| Parallel Capability | 6 |
| Safety Standard | IEC/EN 62109-1, IEC/EN 62109-2 |
| Topology | Non-Isolated |
🌡️Environmental Specifications
| Cooling | Intelligent Air Cooling |
| IP Rating | IP65 |
| Noise Level | <55 dB |
| Operating Altitude | 3000 m |
| Operating Temperature Range | -40 to 60 (>45 derating) °C |
| Relative Humidity | 0-100 % |
📏Dimensions
Width
Height
Depth
Weight
✅Certifications
IEC 62109-1EN 62109-1IEC 62109-2EN 62109-2