Felicity Solar Charge Controllers SCCM4524/SCCM4548/SCCM6048/SCCM8048-III
The Felicity SCCM4524-III raises charge current to 45A on the same 12V/24V battery bank as the SCCM3024-III.
Models and prices
- SCCM4524-IIIAED 3,050incl. VAT
- SCCM4548-IIIAED 1,650incl. VAT
- SCCM6048-IIIAED 1,590incl. VAT
- SCCM8048-IIIAED 1,590incl. VAT
Technical Specifications
| Parameter | SCCM4524-III | SCCM4548-III | SCCM6048-III | SCCM8048-III |
|---|---|---|---|---|
| PV String Input Data | ||||
| PV Start-up Voltage | 20V | |||
| Electrical / AC Output Data | ||||
| Nominal System Voltage | 12-24 V | 12-48 V | 12-48 V | 12-48 V |
| Battery Data | ||||
| Temperature Compensation Coefficient | -5 mV/°C/cell (25°Cref.) | |||
| Additional Specifications | ||||
| Maximum Charge Current | 45 A | 45 A | 60 A | 80 A |
| MPPT Voltage Range | 18-80 V | 18-125 V | 18-125 V | 18-125 V |
| Maximum PV Input Voltage | 95 V | 145 V | 145 V | 145 V |
| Maximum PV Input Power | 625-1250 W | 625-2500 W | 825-3300 W | 1100-4400 W |
| Maximum Efficiency | 98% | |||
| Charging Algorithm | 3-Step | |||
| Supported Battery Types | AGM, Gel, Flooded, Lithium, User-Defined | |||
| Communication | RS485, CAN, MODBUS, Bluetooth, WiFi | |||
| Ingress Protection | IP20 | |||
| Surge Protection | 4500 W/port | |||
| Installation | Wall-Mounted | |||
| Net Weight | 1.5 kg | 3.3 kg | 3.3 kg | 3.5 kg |
| Performance & Electrical | ||||
| System Nominal Voltage | 12-24 V | 12-48 V | 12-48 V | 12-48 V |
| Max Charge Current | 45 A | 45 A | 60 A | 80 A |
| Max PV Input Power | 625-1250 W | 625-2500 W | 825-3300 W | 1100-4400 W |
| Max PV Input Voltage | 95 V | 145 V | 145 V | 145 V |
| Max Efficiency | 98% | |||
| Temperature Compensation Range | 0-50 °C | |||
| Protection Features | Solar high voltage disconnect, Solar high voltage reconnect, Battery high voltage disconnect, Battery high voltage reconnect, High temperature disconnect, High temperature reconnect | |||
| Operating Temperature | 0°C to +55 °C | |||
| Storage Temperature Range | -25 °C to +75 °C | |||
| Build & Interfaces | ||||
| Display | LCD | |||
| Communication Interface | RS485, CAN, MODBUS, Bluetooth, WiFi | |||
| Overall Dimensions | 221 x 151.4 x 80.5 mm | 276.4 x 184.4 x 100 mm | 276.4 x 184.4 x 100 mm | 289.4 x 198.4 x 103.6 mm |
| Weight | 1.5 kg | 3.3 kg | 3.3 kg | 3.5 kg |
| Gross Weight | 1.9 kg | 3.7 kg | 3.7 kg | 4 kg |
| Package Dimensions | 265 x 188 x 116 mm | 308 x 212 x 125 mm | 308 x 212 x 125 mm | 322 x 238 x 140 mm |
| Operating Conditions | ||||
| Relative Humidity | 0-90 (non-condensing)% | |||
| Operating Environment | ||||
| IP Rating | IP20 | |||
Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.
Availability & grid compliance in the UAE
| Market | UAE |
|---|---|
| Grid authority / regulator | DEWA, ADDC, SEWA |
| Quotation currency | AED |
| Support hours timezone | Asia/Dubai |
| Main cities | Dubai, Abu Dhabi, Sharjah, Ajman, Ras Al Khaimah |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in the UAE that rests with the local authorities (DEWA, ADDC, SEWA). Confirm the grid code, import requirements and any local certification with them, or with us, before you order.
Frequently Asked Questions
How many amps can the SCCM4524-III charge at?
45 A is its maximum charge current, into a 12-24 V bank that the controller detects automatically. Every figure here is from the manufacturer's data for the SCCM4524-III.
What is the biggest solar array the SCCM4524-III takes?
Maximum PV input voltage is 95 V and array power is rated 625-1250 W across the supported battery voltages. Tracking starts once the array reaches 20 V.
Which batteries does the SCCM4524-III work with?
AGM, Gel, Flooded, Lithium, User-Defined — all selectable on the SCCM4524-III's 12-24 V bank at up to 45 A, charged in 3-step stages with a temperature compensation of -5 mV/°C/cell (25 °C ref.).
How many amps can the SCCM4548-III charge at?
45 A is its maximum charge current, into a 12-48 V bank that the controller detects automatically. Every figure here is from the manufacturer's data for the SCCM4548-III.
What is the biggest solar array the SCCM4548-III takes?
Maximum PV input voltage is 145 V and array power is rated 625-2500 W across the supported battery voltages. Tracking starts once the array reaches 20 V.
Which batteries does the SCCM4548-III work with?
AGM, Gel, Flooded, Lithium, User-Defined — all selectable on the SCCM4548-III's 12-48 V bank at up to 45 A, charged in 3-step stages with a temperature compensation of -5 mV/°C/cell (25 °C ref.).
How many amps can the SCCM6048-III charge at?
60 A is its maximum charge current, into a 12-48 V bank that the controller detects automatically. Every figure here is from the manufacturer's data for the SCCM6048-III.
What is the biggest solar array the SCCM6048-III takes?
Maximum PV input voltage is 145 V and array power is rated 825-3300 W across the supported battery voltages. Tracking starts once the array reaches 20 V.
Which batteries does the SCCM6048-III work with?
AGM, Gel, Flooded, Lithium, User-Defined — all selectable on the SCCM6048-III's 12-48 V bank at up to 60 A, charged in 3-step stages with a temperature compensation of -5 mV/°C/cell (25 °C ref.).
How many amps can the SCCM8048-III charge at?
80 A is its maximum charge current, into a 12-48 V bank that the controller detects automatically. Every figure here is from the manufacturer's data for the SCCM8048-III.