Felicity Solar Off-Grid Inverters 4 kW IVPS5048
A 48 V off-grid inverter-charger rated 4 kW real and 5 kVA apparent, with a 50 A charger and a pure sine wave 220 V output at 50/60 Hz.
Models and prices
- IVPS5048AED 1,321incl. VAT
Technical Specifications
| Parameter | IVPS5048 |
|---|---|
| Performance & Electrical | |
| AC Output Voltage | 220 V |
| AC Wiring Mode | L+N+PE |
| Backup Rated Output Power | 4 kW |
| Battery Inputs | 1 |
| Battery Type | AGM, Flooded, Li-Ion, Self-Defined |
| Battery Voltage Range | 42-63 V |
| Bulk Charging Voltage | 57.6 V |
| Charge Algorithm | Three-Stage: Boost CC, Boost CV, Float |
| Float Charging Voltage | 54.4 V |
| High DC Input Recovery Voltage | 62 V |
| High Frequency Disconnect | 65 Hz |
| High Frequency Reconnect | 63 Hz |
| High Line Disconnect Voltage | 280 V |
| High Line Reconnect Voltage | 270 V |
| Input Voltage Range | 90-280 V |
| Input Voltage Range (Appliance Mode) | 90-280 V |
| Input Voltage Range (UPS Mode) | 170-280 V |
| Input Voltage Waveform | Sinusoidal (utility or generator) |
| Line Mode Efficiency | >95% |
| Line Mode Output Waveform | Same As Input Waveform |
| Low DC Shutdown (>50% Load) | 42 V |
| Low Frequency Disconnect | 40 Hz |
| Low Frequency Reconnect | 42 Hz |
| Low Line Disconnect (Appliance Mode) | 90 V |
| Low Line Disconnect (UPS Mode) | 170 V |
| Low Line Reconnect (Appliance Mode) | 100 V |
| Low Line Reconnect (UPS Mode) | 180 V |
| Low-Battery Recovery (>50% Load) | 46 V |
| Max AC Charge Current | 50 A |
| Max AC Input Voltage | 280 V |
| Max AC Pass-Through Current | 63 A |
| Max Charging Current | 50 A |
| Max Charging Voltage | 61.0 V |
| Max Efficiency | 90% |
| Motor Start Capable | Yes |
| Nominal AC Input Voltage | 220 V |
| Nominal DC Input Voltage | 48 V |
| Nominal Input Frequency | 50/60 Hz |
| Output Frequency | 50/60 Hz |
| Output Short-Circuit Protection | Yes |
| Output Voltage Regulation | 5% |
| Output Voltage Waveform | Pure Sine Wave |
| Overload Protection | Air Switch Protection |
| Overload Trip Time (>105% Load) | 10 s |
| Overload Trip Time (>150% Load) | 5 s |
| Pass-Through Without Battery | No |
| Phase | Single Phase |
| Protection | Over Charge Protection, Over Discharge Protection, Overload Protection, Output Short Circuit Protection, Over Temperature Protection |
| Rated Apparent Output Power | 5 kVA |
| Rated Output Power | 4 kW |
| Short-Circuit Protection (Line Mode) | Air Switch Protection |
| Start-Up Voltage | 46 V |
| Surge Rating | 2*rated (5s) |
| Transfer Time | 15 ms |
| Build & Interfaces | |
| BMS Communication | RS485 |
| Communication Interface | RS232 |
| Display | LCD, LED |
| Gross Weight | 32.5 kg |
| Net Weight | 29.1 kg |
| Package Dimensions | 607 x 540 x 290 mm |
| Parallel Capability | 6 |
| Topology | Low-Frequency (transformer-based) |
| Operating Environment | |
| Cooling | Intelligent Air Cooling |
| IP Rating | IP21 |
| Operating Temperature Range | 0-40 °C |
| Storage Temperature | -15 to 60 °C |
Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.
Availability & grid compliance in the UAE
| Market | UAE |
|---|---|
| Grid authority / regulator | DEWA, ADDC, SEWA |
| Quotation currency | AED |
| Support hours timezone | Asia/Dubai |
| Main cities | Dubai, Abu Dhabi, Sharjah, Ajman, Ras Al Khaimah |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in the UAE that rests with the local authorities (DEWA, ADDC, SEWA). Confirm the grid code, import requirements and any local certification with them, or with us, before you order.
Key Features & Technical Highlights
- 4 kW real / 5 kVA apparent single-phase output at 220 V, 50/60 Hz, L+N+PE wiring
- 48 V nominal battery input, operating across 42-63 V with start-up at 46 V
- 50 A maximum charging current on a three-stage algorithm: 57.6 V bulk, 54.4 V float
- Low-frequency design surges to twice rated power for 5 seconds and is motor-start capable
- Wide AC input: 90-280 V in appliance mode, 170-280 V in UPS mode, 63 A pass-through
- Up to 6 units in parallel; IP21 enclosure, 494 x 420 x 195 mm, 29.1 kg net
Frequently Asked Questions
What is the rated output of the Felicity Solar IVPS5048?
It is rated 4 kW of real power and 5 kVA apparent power, single phase, with a pure sine wave 220 V output at 50/60 Hz. The low-frequency design also carries twice its rated power for 5 seconds and is motor-start capable.
What battery bank does the IVPS5048 need?
A 48 V nominal bank. It works across 42-63 V, starts up at 46 V and shuts down at 43 V below half load or 42 V above it. It charges AGM, flooded, lithium-ion and self-defined batteries at up to 50 A, with RS485 BMS communication.
Can the IVPS5048 run from a generator?
Yes. It accepts a sinusoidal utility or generator input at 90-280 V in appliance mode, or 170-280 V in UPS mode, and passes through up to 63 A. A battery must be connected, because the unit does not pass power through without one.
How big is the IVPS5048 and can units be paralleled?
The unit measures 494 x 420 x 195 mm and weighs 29.1 kg net, 32.5 kg gross in a 607 x 540 x 290 mm carton. It is IP21 rated with intelligent air cooling for 0 to 40 degrees C, and up to 6 units can be connected in parallel.