Felicity Solar Hybrid Inverters 125 kW IVGM125KHP3G1
Ten MPPT trackers feed the IVGM125KHP3G1 with 250 kW of array, which it turns into 125 kW of three-phase output, 137 kVA at its apparent-power ceiling and 198.6 A of current, drawn against a 160-950 V LFP bank on two inputs.
Models and prices
- IVGM125KHP3G1AED 1,680incl. VAT
Technical Specifications
| Parameter | IVGM125KHP3G1 |
|---|---|
| Performance & Electrical | |
| AC Output Line Voltage | 380-400 V |
| AC Output Voltage | 220-230 V |
| AC Rated Output Current | 181.2 A |
| AC Wiring Mode | 3L+N+PE |
| Backup Rated Output Power | 125 kW |
| Battery Inputs | 2 |
| Battery Type | LFP |
| Battery Voltage Range | 160-950 V |
| Charge Algorithm | Self-Adaption to BMS |
| Grid Frequency Range (50 Hz) | 45-55 Hz |
| Grid Frequency Range (60 Hz) | 55-65 Hz |
| Grid Regulation | IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4110 |
| Ground Fault Current Monitoring | Yes |
| Input Voltage Range | 184-264.5 V |
| MPPT Full-Load Voltage Range | 555-950 V |
| MPPT Trackers | 10 |
| MPPT Voltage Range | 150-950 V |
| Max AC Input Current | 198.6 A |
| Max AC Pass-Through Current | 270 A |
| Max Apparent Power | 137 kVA |
| Max Charging Current | 120+120 A |
| Max Discharging Current | 120+120 A |
| Max Efficiency | 97.6% |
| Max Output Current | 198.6 A |
| Max Output Overcurrent Protection | 270 A |
| Max PV Input Current | 45+45+45+45+45+45+45+45+45+45 A |
| Max PV Input Power | 250 kW |
| Max PV Voltage | 1000 V |
| Max Short-Circuit Current | 68+68+68+68+68+68+68+68+68+68 A |
| Nominal AC Input Line Voltage | 380-400 V |
| Nominal AC Input Voltage | 220-230 V |
| Nominal Input Frequency | 50/60 Hz |
| Output Frequency | 50/60 Hz |
| Output Short-Circuit Protection | Yes |
| Overload Protection | Yes |
| Overvoltage Category (AC) | III |
| Overvoltage Category (DC) | II |
| Phase | Three Phase |
| Power Factor Adjustment Range | 0.8 leading to 0.8 lagging |
| Protection | PV Input Lightning Protection, PV String Input Reverse Polarity Protection, Battery Input Lightning Protection, Battery Input Reverse Polarity Protection, DC Component Detection, Insulation Resistor Detection, Residual Current Monitoring Unit, Arc Fault Monitoring (optional), Output Over Current Protection, Output Shorted Protection, Output Over Voltage Protection, Remaining Current (RCD) Monitoring, Overheat Protection, Anti-islanding Protection, AC Output Lightning Protection |
| Rated Apparent Output Power | 125 kVA |
| Rated Output Power | 125 kW |
| Rated PV Input Voltage | 600 V |
| Start-Up Voltage | 180 V |
| Strings per MPPT | 2 |
| Surge Protection Level (AC) | III |
| Surge Protection Level (DC) | III |
| Surge Rating | 1.5*rated (10s) |
| Total Harmonic Distortion | <3% |
| Transfer Time | 0 ms |
| Build & Interfaces | |
| BMS Communication | RS485, CAN |
| Communication Interface | RS232, RS485 |
| Display | LCD, LED |
| Gross Weight | 198 kg |
| Installation Style | Wall-Mounted |
| Monitoring Module | WiFi/Bluetooth/4G/LAN (optional) |
| Net Weight | 155.5 kg |
| Package Dimensions | 1410 x 960 x 646 mm |
| Parallel Capability | 12 |
| Safety Standard | IEC/EN 62109-1, IEC/EN 62109-2 |
| Topology | Non-Isolated |
| Operating Environment | |
| Cooling | Smart Cooling |
| IP Rating | IP66 |
| Operating Altitude | 4000 m |
| Operating Temperature Range | -40 to 60 (>45 derating) °C |
| Relative Humidity | 0-100 (non-condensing)% |
Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.
Availability & grid compliance in the UAE
| Market | UAE |
|---|---|
| Grid authority / regulator | DEWA, ADDC, SEWA |
| Quotation currency | AED |
| Support hours timezone | Asia/Dubai |
| Main cities | Dubai, Abu Dhabi, Sharjah, Ajman, Ras Al Khaimah |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in the UAE that rests with the local authorities (DEWA, ADDC, SEWA). Confirm the grid code, import requirements and any local certification with them, or with us, before you order.
Key Features & Technical Highlights
- 125 kW rated output and 137 kVA of maximum apparent power: Rated output power is 125 kW and rated apparent output power 125 kVA, rising to 137 kVA at maximum, with a 125 kW backup output that transfers in 0 ms and surge capacity of 1.5 times rated power for 10 seconds.
- 250 kW of PV input across 10 MPPT trackers: Maximum PV input power is 250 kW over 10 MPPT trackers carrying two strings each, 45 A of input current and 68 A of short-circuit current per tracker, up to a 1000 V maximum PV voltage, tracking 150-950 V from a 180 V start-up and 555-950 V at full load.
- Two battery inputs moving 120+120 A across 160-950 V: Two battery inputs charge and discharge LFP packs at 120+120 A anywhere between 160 V and 950 V, with a charge algorithm that self-adapts to the BMS over RS485 and CAN.
- 3L+N+PE output rated 181.2 A and 198.6 A at maximum: AC wiring is 3L+N+PE at 380-400 V line to line and 220-230 V per phase, rated 181.2 A, maximum 198.6 A in and out, protected at 270 A with 270 A of pass-through, THD below 3% and a power factor adjustable from 0.8 leading to 0.8 lagging.
- 97.6% maximum efficiency with overvoltage category III: Maximum efficiency is 97.6%; the non-isolated design carries overvoltage category III on the AC side and II on the DC side, surge protection level III on both, ground fault current monitoring, and certification to IEC 62109-1, EN 62109-1, IEC 62109-2 and EN 62109-2.
- 1271 x 810 x 364 mm IP66 cabinet, 155.5 kg net, 12 in parallel: The smart-cooled, wall-mounted IP66 cabinet measures 1271 x 810 x 364 mm and weighs 155.5 kg net and 198 kg gross in a 1410 x 960 x 646 mm carton, works from -40 to 60 °C with derating above 45 °C, to 4000 m and 0-100% non-condensing humidity, and parallels up to 12 units. Warranty: 2 Years.
Frequently Asked Questions
How much solar can the IVGM125KHP3G1 take?
250 kW is the maximum PV input power, spread over 10 MPPT trackers with two strings each. Every tracker takes 45 A of input current and 68 A of short-circuit current, tracks from 150 V to 950 V after a 180 V start-up and narrows to 555-950 V at full load, around a 600 V rated PV input voltage and a 1000 V maximum PV voltage.
What battery does the IVGM125KHP3G1 work with?
LFP packs between 160 V and 950 V, on two battery inputs that charge and discharge at 120+120 A. The charge algorithm self-adapts to the BMS over RS485 and CAN, and the 125 kW backup output takes over in 0 ms.
What does the IVGM125KHP3G1 deliver on the AC side?
125 kW rated output power and 125 kVA rated apparent output power, three phase, rising to 137 kVA at maximum. Rated output current is 181.2 A and both maximum AC input current and maximum output current are 198.6 A, behind 270 A of output overcurrent protection and 270 A of pass-through, at 380-400 V line to line and 220-230 V per phase on 3L+N+PE wiring, 50/60 Hz across 45-55 Hz and 55-65 Hz windows, with THD under 3%. Grid settings cover IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99 and VDE-AR-N 4110.
Where can the IVGM125KHP3G1 be installed and what warranty does it carry?
The IP66 wall-mounted cabinet runs from -40 to 60 °C with derating above 45 °C, to 4000 m of altitude and 0-100% non-condensing humidity. It measures 1271 x 810 x 364 mm, weighs 155.5 kg net and 198 kg gross, is monitored by optional WiFi, Bluetooth, 4G or LAN behind an LCD and LED panel, parallels to 12 units, and carries a 2 Years warranty.