Felicity Solar Hybrid Inverters 5-10 kW IVGM10KLP3/IVGM5KLP2/IVGM6KLP2/IVGM7K6LP2/IVGM8KLP2G1
The Felicity Solar IVGM10KLP3G1 is a 10 kW three-phase hybrid solar inverter rated 10 kVA at 380-400 V, with 97.6% peak efficiency and 15 kW of PV input. Two MPPT trackers and a 40-60 V battery port charging at up to 210 A make it a full grid-tied, off-grid and UPS solution.
Models and prices
- IVGM10KLP3G1AED 5,500incl. VAT
- IVGM5KLP2G1AED 2,300incl. VAT
- IVGM6KLP2G1AED 2,750incl. VAT
- IVGM7K6LP2G1AED 3,490incl. VAT
- IVGM8KLP2G1AED 3,670incl. VAT
Technical Specifications
| Parameter | IVGM10KLP3G1 | IVGM5KLP2G1 | IVGM6KLP2G1 | IVGM7K6LP2G1 | IVGM8KLP2G1 |
|---|---|---|---|---|---|
| Performance & Electrical | |||||
| AC Output Line Voltage | 380-400 V | ||||
| AC Output Voltage | 220-230 V | ||||
| AC Rated Output Current | 14.5 A | 20.8 A | 25 A | 31.7 A | 33.3 A |
| AC Wiring Mode | 3L+N+PE | L+N+PE | L+N+PE | L+N+PE | L+N+PE |
| Backup Rated Output Power | 10 kW | 5 kW | 6 kW | 7.6 kW | 8 kW |
| Battery Inputs | 2 | 1 | 1 | 1 | 1 |
| Battery Type | Lead-Acid, Li-Ion | ||||
| Battery Voltage Range | 40-60 V | ||||
| Charge Algorithm | Self-Adaption to BMS | ||||
| DC Switch | Yes | ||||
| Grid Frequency Range (50 Hz) | 45-55 Hz | ||||
| Grid Frequency Range (60 Hz) | 55-65 Hz | ||||
| Grid Regulation | NRS 097-2-1, VDE4105, EN50549-1, AS 4777.2, GB/T 34120, GB/T 34133, GB/T 34129 | CEI 0-21, G99, VDE 4105, EN 50549-1, NRS 097-2-1, C10/11, NTS & UNE217001 & UNE217002, PORTARIA N° 140 & 515 | VDE 4105, CEI 0-21, G99, NRS 097-2-1, EN 50549-1, EN 50549-10, NC RFG (Poland), EN 50549-1/-10+Netherlands, PPDS, NTS & UNE217001 & UNE217002, UL1741 (in progress) | VDE 4105, CEI 0-21, G99, NRS 097-2-1, EN 50549-1, EN 50549-10, NC RFG (Poland), EN 50549-1/-10+Netherlands, PPDS, NTS & UNE217001 & UNE217002, UL1741 (in progress) | VDE 4105, CEI 0-21, G99, NRS 097-2-1, EN 50549-1, EN 50549-10, NC RFG (Poland), EN 50549-1/-10+Netherlands, PPDS, NTS & UNE217001 & UNE217002, UL1741 (in progress) |
| Ground Fault Current Monitoring | Yes | ||||
| Input Voltage Range | 184-264.5 V | ||||
| MPPT Efficiency | 99.9% | ||||
| MPPT Full-Load Voltage Range | 289-800 V | 290-425 V | 230-425 V | 230-425 V | 230-425 V |
| MPPT Trackers | 2 | ||||
| MPPT Voltage Range | 160-650 V | 120-425 V | 120-425 V | 120-425 V | 120-425 V |
| Max AC Input Current | 16 A | 40 A | 40 A | — | — |
| Max AC Pass-Through Current | 70 A | 40 A | 40 A | 50 A | 50 A |
| Max Apparent Power | 11 kVA | ||||
| Max Charging Current | 210 A | 120 A | 135 A | 190 A | 190 A |
| Max Discharging Current | 210 A | 120 A | 135 A | 190 A | 190 A |
| Max Efficiency | 97.6% | ||||
| Max Output Current | 16 A | 22.9 A | 27.5 A | 34.8 A | 36.7 A |
| Max Output Overcurrent Protection | 65 A | ||||
| Max PV Input Current | 26+26 A | 13+13 A | 26+13 A | 26+26 A | 26+26 A |
| Max PV Input Power | 15 kW | ||||
| Max PV Voltage | 800 V | 500 V | 500 V | 500 V | 500 V |
| Max Short-Circuit Current | 39+39 A | 17+17 A | 44+17 A | 44+44 A | 44+44 A |
| Nominal AC Input Line Voltage | 380-400 V | ||||
| Nominal AC Input Voltage | 220-230 V | ||||
| Nominal Input Frequency | 50/60 Hz | ||||
| Output Frequency | 50/60 Hz | ||||
| Output Short-Circuit Protection | Yes | ||||
| Overload Protection | Yes | ||||
| Pass-Through Without Battery | Yes | ||||
| Phase | Three Phase | Single Phase | Single Phase | Single Phase | Single Phase |
| Power Factor Adjustment Range | 0.8 leading to 0.8 lagging | ||||
| Protection | DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, Thermal Protection, DC Terminal Insulation Impedance Monitoring, DC Component Monitoring, Ground Fault Current Monitoring, Arc Fault Circuit Interrupter (AFCI), Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch, Overvoltage Load Drop Protection, Residual Current (RCD) Detection | Output Over Current Protection, Output Over Power Protection, Output Short-Circuit Protection, Anti-islanding Protection, GFCI Protection, Insulation Resistor Detection | Output Over Current Protection, Output Over Power Protection, Output Short-Circuit Protection, Anti-islanding Protection, GFCI Protection, Insulation Resistor Detection | Output Over Current Protection, Output Over Power Protection, Output Short-Circuit Protection, Anti-islanding Protection, GFCI Protection, Insulation Resistor Detection | Output Over Current Protection, Output Over Power Protection, Output Short-Circuit Protection, Anti-islanding Protection, GFCI Protection, Insulation Resistor Detection |
| Rated Apparent Output Power | 10 kVA | 5 kVA | 6 kVA | 7.6 kVA | 8 kVA |
| Rated Output Power | 10 kW | 5 kW | 6 kW | 7.6 kW | 8 kW |
| Rated PV Input Voltage | 550 V | 380 V | 380 V | 380 V | 380 V |
| Start-Up Voltage | 160 V | 100 V | 100 V | 100 V | 100 V |
| Strings per MPPT | 2+2 | 1+1 | 2+1 | 2 | 2 |
| Surge Protection Level (AC) | II | ||||
| Surge Protection Level (DC) | II | ||||
| Surge Rating | 2*rated (10s) | ||||
| Total Harmonic Distortion | <3% | ||||
| Transfer Time | 20 ms | 10 ms | 10 ms | 10 ms | 10 ms |
| European Efficiency | 97% | ||||
| Max AC Output Power | — | 5.5 kW | 6.6 kW | 8.36 kW | 8.8 kW |
| Max Charge/Discharge Power | — | 5 kW | 6 kW | 7.6 kW | 8 kW |
| Max Recommended PV Power | — | 7.5 kW | 9 kW | 11.4 kW | 12 kW |
| PV Working Voltage Range | 90-500 V | ||||
| Power Factor | >0.99 | ||||
| Build & Interfaces | |||||
| BMS Communication | RS485, CAN | ||||
| Communication Interface | RS232, RS485 | ||||
| Display | LCD Touch Screen | LCD, LED | LCD, LED | LCD, LED | LCD, LED |
| Gross Weight | 60.2 kg | 40.5 kg | 40.5 kg | 40.5 kg | 40.5 kg |
| Installation Style | Wall-Mounted | ||||
| Monitoring Module | WiFi/4G | WiFi/GPRS | WiFi/GPRS | WiFi/GPRS | WiFi/GPRS |
| Net Weight | 48.7 kg | 33.5 kg | 33.5 kg | 33.5 kg | 33.5 kg |
| Package Dimensions | 889 x 566 x 397 mm | 787 x 547 x 358 mm | 787 x 547 x 358 mm | 787 x 547 x 358 mm | 787 x 547 x 358 mm |
| Parallel Capability | 10 | 6 | 6 | 6 | 6 |
| Safety Standard | IEC/EN 62109-1, IEC/EN 62109-2 | IEC 62109-1, IEC 62109-2 | IEC 62109-1, IEC 62109-2 | IEC 62109-1, IEC 62109-2 | IEC 62109-1, IEC 62109-2 |
| Topology | Non-Isolated | Isolated (transformer-based) | Isolated (transformer-based) | Isolated (transformer-based) | Isolated (transformer-based) |
| Operating Environment | |||||
| Cooling | Smart Cooling | ||||
| IP Rating | IP65 | ||||
| Operating Altitude | 2000 m | ||||
| Operating Temperature Range | -25 to 60 (>45 derating) °C | ||||
| Noise Level | <35 dB | ||||
| Relative Humidity | 0-95 (non-condensing)% | ||||
Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.
Availability & grid compliance in the UAE
| Market | UAE |
|---|---|
| Grid authority / regulator | DEWA, ADDC, SEWA |
| Quotation currency | AED |
| Support hours timezone | Asia/Dubai |
| Main cities | Dubai, Abu Dhabi, Sharjah, Ajman, Ras Al Khaimah |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in the UAE that rests with the local authorities (DEWA, ADDC, SEWA). Confirm the grid code, import requirements and any local certification with them, or with us, before you order.
Key Features & Technical Highlights
- 10 kW rated output and 10 kVA apparent power, 11 kVA maximum, at 380-400 V three-phase in a 3L+N+PE wiring mode
- 97.6% maximum conversion efficiency with 99.9% MPPT tracking efficiency and total harmonic distortion below 3%
- 15 kW maximum PV input over 2 MPPT trackers and 2+2 strings, 160-650 V MPPT range and 800 V maximum PV voltage
- Two battery inputs at 40-60 V with up to 210 A charge and 210 A discharge, lithium-ion or lead-acid, BMS over RS485 or CAN
- 20 ms transfer time and 70 A AC pass-through across programmable on-grid, off-grid and UPS modes, 2x rated surge for 10 s
- IP65 wall-mounted enclosure with smart cooling, -25 °C to 60 °C operating range and up to 10 units in parallel
- 5.5 kW maximum AC output from a 5 kW rating: Single-phase 220-230 V on an L+N+PE connection at up to 22.9 A, with a surge of 2x rated for 10 s.
- 120 A charging and 120 A discharging, up to 5 kW either way: One battery input carries a 40-60 V lead-acid or Li-Ion bank and reads its BMS over RS485 and CAN.
- 7.5 kW of recommended PV on two MPP trackers: The trackers take 13+13 A across a 120-425 V window rated 380 V, from a 100 V start-up to 500 V.
- 97.6% peak efficiency and 99.9% MPPT efficiency: European efficiency is 97%, power factor sits above 0.99 and total harmonic distortion stays under 3%.
- IP65 enclosure rated -25 to 60 °C, derating above 45 °C: Smart cooling holds noise under 35 dB at up to 2000 m and 0-95% non-condensing humidity.
- Up to 6 units in parallel with a 10 ms transfer time: Wall-mounted at 33.5 kg net, LCD and LED display, WiFi or GPRS monitoring, RS232 and RS485 ports.
Frequently Asked Questions
What is the Felicity Solar IVGM10KLP3G1?
The IVGM10KLP3G1 is a 10 kW three-phase hybrid solar inverter from Felicity Solar. It delivers 10 kW of rated output power and 10 kVA of rated apparent power, with 11 kVA maximum apparent power and 14.5 A rated output current at a 380-400 V line voltage (220-230 V per phase, 3L+N+PE). Maximum conversion efficiency is 97.6%.
How many solar panels can the IVGM10KLP3G1 take?
The IVGM10KLP3G1 accepts up to 15 kW of PV input across 2 MPPT trackers carrying 2+2 strings. Maximum PV voltage is 800 V, the MPPT range is 160-650 V with a 289-800 V full-load window, rated PV input voltage is 550 V and the unit starts up at 160 V. Maximum PV input current is 26+26 A.
Which batteries work with the IVGM10KLP3G1?
It has 2 battery inputs covering a 40-60 V range and works with lithium-ion or lead-acid banks. Charge and discharge current both reach 210 A, and the charge algorithm self-adapts to the battery BMS over RS485 or CAN. The inverter also passes grid power through to the loads without a battery connected.
What are the dimensions, weight and operating limits of the IVGM10KLP3G1?
The unit measures 750 x 450 x 268 mm and weighs 48.7 kg net; packed it is 889 x 566 x 397 mm at 60.2 kg gross. It is wall-mounted, IP65 rated, operates from -25 °C to 60 °C with derating above 45 °C, and works up to 2000 m altitude. Safety standards are IEC 62109-1, EN 62109-1, IEC 62109-2 and EN 62109-2.
How much solar can the IVGM5KLP2G1 take?
7.5 kW is the maximum recommended PV power, split across two MPP trackers that accept 13+13 A over a 120-425 V window rated at 380 V, start tracking from 100 V, reach 500 V at most and track at 99.9% efficiency.
How fast does the IVGM5KLP2G1 charge and discharge a battery?
120 A in each direction, up to 5 kW of charge or discharge power, on one battery input sized for a 40-60 V lead-acid or Li-Ion bank whose BMS is read over RS485 and CAN.
What is the maximum AC output of the IVGM5KLP2G1?
5.5 kW is the ceiling, above a 5 kW rated and 5 kW backup output, delivered single-phase at 220-230 V and up to 22.9 A on an L+N+PE connection; AC input current tops out at 40 A and transfer takes 10 ms.
What warranty and certification does the IVGM5KLP2G1 carry?
10 Years is the warranty term, and the unit is certified to IEC 62109-1 and IEC 62109-2, with grid support for CEI 0-21, G99, VDE 4105, EN 50549-1 and NRS 097-2-1. We are an authorised Felicity Solar distributor.
What is the maximum output current of the IVGM6KLP2G1?
27.5 A. That sits behind a 6 kW rating and a 6.6 kW maximum AC output at 220-230 V, single phase, wired L+N+PE, with a power factor above 0.99 and harmonic distortion under 3%.
How much solar can the IVGM6KLP2G1 take?
9 kW of recommended array. Its two MPPT trackers accept 26+13 A of PV input to 500 V, track between 120-425 V from a 380 V nominal PV input, and get going at 100 V.